Network Working Group | T. Otani |
Internet-Draft | K. Ogaki |
Intended status: Informational | KDDI |
Expires: December 12, 2013 | D. Caviglia |
Ericsson | |
F. Zhang | |
Huawei Technologies | |
C. Margaria | |
Coriant R&D GmbH | |
June 10, 2013 |
Requirements for GMPLS applications of PCE
draft-ietf-pce-gmpls-aps-req-08.txt
The initial effort of the PCE (Path computation element) WG is specifically focused on MPLS. As a next step, this draft describes functional requirements for GMPLS application of PCE.
This Internet-Draft is submitted in full conformance with the provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering Task Force (IETF). Note that other groups may also distribute working documents as Internet-Drafts. The list of current Internet-Drafts is at http://datatracker.ietf.org/drafts/current/.
Internet-Drafts are draft documents valid for a maximum of six months and may be updated, replaced, or obsoleted by other documents at any time. It is inappropriate to use Internet-Drafts as reference material or to cite them other than as "work in progress."
This Internet-Draft will expire on December 12, 2013.
Copyright (c) 2013 IETF Trust and the persons identified as the document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info) in effect on the date of publication of this document. Please review these documents carefully, as they describe your rights and restrictions with respect to this document. Code Components extracted from this document must include Simplified BSD License text as described in Section 4.e of the Trust Legal Provisions and are provided without warranty as described in the Simplified BSD License.
The initial effort of the PCE (Path computation element) WG is focused on solving the path computation problem within a domain or over different domains in MPLS networks. As the same case with MPLS, service providers (SPs) have also come up with requirements for path computation in GMPLS-controlled networks [RFC3945] such as wavelength, TDM-based or Ethernet-based networks as well.
[RFC4655] and [RFC4657] discuss the framework and requirements for PCE on both packet MPLS networks and GMPLS-controlled networks. This document complements these RFCs by providing some considerations of GMPLS applications in the intra-domain and inter-domain networking environments and indicating a set of requirements for the extended definition of PCE-related protocols.
Note that the requirements for inter-layer and inter-area traffic engineering described in [RFC6457] and [RFC4927] are outside of the scope of this document.
Constraint-based shortest path first (CSPF) computation within a domain or over domains for signaling GMPLS Label Switched Paths (LSPs) is usually more stringent than that of MPLS TE LSPs [RFC4216], because the additional constraints, e.g., interface switching capability, link encoding, link protection capability, SRLG (Shared risk link group) [RFC4202] and so forth need to be considered to establish GMPLS LSPs. GMPLS signaling protocol [RFC3473] is designed taking into account bi-directionality, switching type, encoding type and protection attributes of the TE links spanned by the path, as well as LSP encoding and switching type of the end points, appropriately.
This document provides the investigated results of GMPLS applications of PCE for the support of GMPLS path computation. This document also provides requirements for GMPLS applications of PCE in GMPLS intra-domain and inter-domain environments.
Figure 1 depicts a typical GMPLS network, consisting of an ingress link, a transit link as well as an egress link, to investigate a consistent guideline for GMPLS path computation. Each link at each interface has its own switching capability, encoding type and bandwidth.
Ingress Transit Egress +-----+ link1-2 +-----+ link2-3 +-----+ link3-4 +-----+ |Node1|------------>|Node2|------------>|Node3|------------>|Node4| | |<------------| |<------------| |<------------| | +-----+ link2-1 +-----+ link3-2 +-----+ link4-3 +-----+
Figure 1: Path computation in GMPLS networks
For the simplicity in consideration, the below basic assumptions are made when the LSP is created.
(1) Switching capabilities of outgoing links from the ingress and egress nodes (link1-2 and link4-3 in Figure 1) are consistent with each other.
(2) Switching capabilities of all transit links including incoming links to the ingress and egress nodes (link2-1 and link3-4) are consistent with switching type of a LSP to be created.
(3) Encoding-types of all transit links are consistent with encoding type of a LSP to be created.
GMPLS-controlled networks (e.g., GMPLS-based TDM networks) are usually responsible for transmitting data for the client layer. These GMPLS-controlled networks can provide different types of connections for customer services based on different service bandwidth requests.
The applications and the corresponding additional requirements for applying PCE to, for example, GMPLS-based TDM networks, are described in Figure 2. In order to simplify the description, this document just discusses the scenario in SDH networks as an example. The scenarios in SONET or G.709 ODUk layer networks are similar to this scenario.
N1 N2 +-----+ +------+ +------+ | |-------| |--------------| | +-------+ +-----+ | |---| | | | | A1 +------+ | +------+ | | | | | +-------+ | | | PCE | | | | +------+ | | | | | | | |-----| | | +------+ | | | N5 | | | | | +------+ +------+ | | | | +-----+ | |--------------| |--------| | +------+ +------+ +-----+ N3 N4 A2
Figure 2: A simple TDM (SDH) network
Figure 2 shows a simple TDM (SDH) network topology, where N1, N2, N3, N4 and N5 are all SDH switches. Assume that one Ethernet service with 100M bandwidth is required from A1 to A2 over this network. The client Ethernet service could be provided by a VC4 connection from N1 to N4, and it could also be provided by three concatenated VC3 connections (Contiguous or Virtual concatenation) from N1 to N4.
In this scenario, when the ingress node (e.g., N1) receives a client service transmitting request, the type of connections (one VC4 or three concatenated VC3) could be determined by PCC (Path computation client) (e.g., N1 or NMS), but could also be determined by PCE automatically based on policy [RFC5394]. If it is determined by PCC, PCC should be capable of specifying the ingress node and egress node, signal type, the type of the concatenation and the number of the concatenation in a PCReq (Path computation request) message. PCE should consider those parameters during path computation. The route information (co-route or separated-route) should be specified in a PCRep (Path computation reply) message if path computation is performed successfully.
As described above, PCC should be capable of specifying TE attributes defined in the next section and PCE should compute a path accordingly.
Where a GMPLS network is consisting of inter-domain (e.g., inter-AS or inter-area) GMPLS-controlled networks, requirements on the path computation follows [RFC5376] and [RFC4726].
GMPLS supports unnumbered interface ID that is defined in [RFC3477], which means that the endpoints of the path may be unnumbered. It should also be possible to request a path consisting of the mixture of numbered links and unnumbered links, or a P2MP (Point-to-multipoint) path with different types of endpoints. Therefore, the PCC should be capable of indicating the unnumbered interface ID of the endpoints in the PCReq message.
As per [RFC6387], GMPLS signaling can be used for setting up an asymmetric bandwidth bidirectional LSP. If a PCE is responsible for the path computation, the PCE should be capable of computing a path for the bidirectional LSP with asymmetric bandwidth. It means that the PCC should be able to indicate the asymmetric bandwidth requirements in forward and reverse directions in the PCReq message.
As for path computation in GMPLS-controlled networks as discussed in section 2, the PCE should consider the GMPLS TE attributes appropriately once a PCC or another PCE requests a path computation. Indeed, the path calculation request message from the PCC or the PCE must contain the information specifying appropriate attributes. According to [RFC5440], [PCE-WSON-REQ] and to RSVP procedures like explicit label control(ELC),the additional attributes introduced are as follows:
(1) Switching capability/type: as defined in [RFC3471], [RFC4203] and, all current and future values.
(2) Encoding type: as defined in [RFC3471], [RFC4203] and, all current and future values.
(3) Signal Type: as defined in [RFC4606] and, all current and future values.
(4) Concatenation Type: In SDH/SONET and G.709 ODUk networks, two kinds of concatenation modes are defined: contiguous concatenation which requires co-route for each member signal and requires all the interfaces along the path to support this capability, and virtual concatenation which allows diverse routes for the member signals and only requires the ingress and egress interfaces to support this capability. Note that for the virtual concatenation, it also may specify co-routed or separated-routed. See [RFC4606] and [RFC4328] about concatenation information.
(5) Concatenation Number: Indicates the number of signals that are requested to be contiguously or virtually concatenated. Also see [RFC4606] and [RFC4328].
(6) Technology-specific label(s) such as defined in [RFC4606], [RFC6060], [RFC6002] or [RFC6205].
(7) e2e Path protection type: as defined in [RFC4872], e.g., 1+1 protection, 1:1 protection, (pre-planned) rerouting, etc.
(8) Administrative group: as defined in [RFC3630]
(9) Link Protection type: as defined in [RFC4203]
(10)Support for unnumbered interfaces: as defined in [RFC3477]
(11)Support for asymmetric bandwidth request: as defined in [RFC6387]
(12)Support for explicit label control during the path computation.
(13)Support of label restrictions in the requests/responses, similarly to RSVP-TE ERO (Explicit route object) and XRO (Exclude route object) as defined in [RFC3473] and [RFC4874].
As described above, a PCE should compute the path that satisfies the constraints which are specified in the PCReq message. Then the PCE should send a PCRep message including the computation result to the PCC. For Path Computation Reply message (PCRep) in GMPLS networks, there are some additional requirements. The PCEP (PCE communication protocol) PCRep message must be extended to meet the following requirements.
(1) Path computation with concatenation
In the case of path computation involving concatenation, when a PCE receives the PCReq message specifying the concatenation constraints described in section 3.1, the PCE should compute a path accordingly.
For path computation involving contiguous concatenation, a single route is required and all the interfaces along the route should support contiguous concatenation capability. Therefore, the PCE should compute a path based on the contiguous concatenation capability of each interface and only one ERO which should carry the route information for the response.
For path computation involving virtual concatenation, only the ingress/egress interfaces need to support virtual concatenation capability and there may be diverse routes for the different member signals. Therefore, multiple EROs may be needed for the response. Each ERO may represent the route of one or multiple member signals. In the case where one ERO represents several member signals among the total member signals, the number of member signals along the route of the ERO must be specified.
(2) Label constraint
In the case that a PCC does not specify the exact label(s) when requesting a label-restricted path and the PCE is capable of performing the route computation and label assignment computation procedure, the PCE needs to be able to specify the label of the path in a PCRep message.
Wavelength restriction is a typical case of label restriction. More generally in GMPLS-controlled networks label switching and selection constraints may apply and a PCC may request a PCE to take label constraint into account and return an ERO containing the label or set of label that fulfil the PCC request.
(3) Roles of the routes
When a PCC specifies the protection type of an LSP, the PCE should compute the working route and the corresponding protection route(s). Therefore, the PCRep should allow to distinguish the working (nominal) and the protection routes. According to these routes, RSVP-TE procedure appropriately creates both the working and the protection LSPs for example with ASSOCIATION object [RFC6689].
PCE-related Management Information Bases must consider extensions to be satisfied with requirements for GMPLS applications. For extensions, [RFC4802] are defined to manage TE database and may be referred to so as to accommodate GMPLS TE attributes in the PCE.
PCEP extensions to support GMPLS should be considered under the same security as current PCE work. This extension will not change the underlying security issues.
This document has no actions for IANA.
The author would like to express the thanks to Ramon Casellas, Julien Meuric, Adrian Farrel and Shuichi Okamoto for their comments.