IS-IS Support for Openfabric
draft-white-openfabric-05
Spine and leaf topologies are widely used in hyperscale and cloud scale networks. In most of these networks, configuration is automated, but difficult, and topology information is extracted through broad based connections. Policy is often integrated into the control plane, as well, making configuration, management, and troubleshooting difficult. Openfabric is an adaptation of an existing, widely deployed link state protocol, Intermediate System to Intermediate System (IS-IS) that is designed to:
This document begins with an overview of openfabric, including a description of what may be removed from IS-IS to enable scaling. The document then describes an optimized adjacency formation process; an optimized flooding scheme; some thoughts on the operation of openfabric, metrics, and aggregation; and finally a description of the changes to the IS-IS protocol required for openfabric.
This Internet-Draft is submitted in full conformance with the provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering Task Force (IETF). Note that other groups may also distribute working documents as Internet-Drafts. The list of current Internet-Drafts is at https://datatracker.ietf.org/drafts/current/.
Internet-Drafts are draft documents valid for a maximum of six months and may be updated, replaced, or obsoleted by other documents at any time. It is inappropriate to use Internet-Drafts as reference material or to cite them other than as "work in progress."
This Internet-Draft will expire on July 6, 2018.
Copyright (c) 2018 IETF Trust and the persons identified as the document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal Provisions Relating to IETF Documents (https://trustee.ietf.org/license-info) in effect on the date of publication of this document. Please review these documents carefully, as they describe your rights and restrictions with respect to this document. Code Components extracted from this document must include Simplified BSD License text as described in Section 4.e of the Trust Legal Provisions and are provided without warranty as described in the Simplified BSD License.
Spine and leaf fabrics are often used in large scale data centers; in this application, they are commonly called a fabric because of their regular structure and predictable forwarding and convergence properties. This document describes modifications to the IS-IS protocol to enable it to run efficiently on a large scale spine and leaf fabric, openfabric. The goals of this control plane are:
The following people have contributed to this draft: Nikos Triantafillis (reflected flooding optimization), Ivan Pepelnjak (three stage fabric modifications), Hannes Gredler (do not reflood optimizations), Les Ginsberg (capabilities encoding, circuit local reflooding), Naiming Shen (capabilities encoding, circuit local reflooding), Uma Chunduri (failure mode suggestions, flooding), Nick Russo, and Rodny Molina.
See [RFC5449], [RFC5614], and [RFC7182] for similar solutions in the Mobile Ad Hoc Networking (MANET) solution space.
In building any scalable system, it is often best to begin by removing what is not needed. In this spirit, openfabric implementations MAY remove the following from IS-IS:
To create a scalable link state fabric, openfabric includes the following:
Three general requirements are placed here; more specific requirements are considered in the following sections. Openfabric implementations:
The following spine and leaf fabric will be used to describe these modifications.
+----+ +----+ +----+ +----+ +----+ +----+ | 1A | | 1B | | 1C | | 1D | | 1E | | 1F | (T0) +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ | 2A | | 2B | | 2C | | 2D | | 2E | | 2F | (T1) +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ | 3A | | 3B | | 3C | | 3D | | 3E | | 3F | (T2) +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ | 4A | | 4B | | 4C | | 4D | | 4E | | 4F | (T1) +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ +----+ | 5A | | 5B | | 5C | | 5D | | 5E | | 5F | (T0) +----+ +----+ +----+ +----+ +----+ +----+
Figure 1
To reduce confusion (spine and leaf fabrics are difficult to draw in plain text art), this diagram does not contain the connections between devices. The reader should assume that each device in a given layer is connected to every device in the layer above it. For instance:
The tiers or stages of the fabric are also marked for easier reference. T0 is assumed to be connected to application servers, or rather they are Top of Rack (ToR) intermediate systems. The remaining tiers, T1 and T2, are connected only to the fabric itself. Note there are no "cross links," or "east west" links in the illustrated fabric. The fabric locality detection mechanism described here will not work if there are cross links running east/west through the fabric. Locality detection may be possible in such a fabric; this is an area for further study.
Because Openfabric operates in a tightly controlled data center environment, various modifications can be made to the IS-IS neighbor formation process to increase efficencicy and simplify the protocol. Specifically, Openfabric implementations SHOULD support [RFC3719], section 4, hello padding for IS-IS. Variable hello padding SHOULD NOT be used, as data center fabrics are built using high speed links on which padded hellos will have little performance impact. Further modifications to the neighbor formation process are considered in the following sections.
Openfabric is designed to work in a single flooding domain over a single data center fabric at the scale of thousands of routers with hundreds of thousands of routes (so a moderate scale in router and route count terms). Because of the way Openfabric optimizes operation in this environment, it is not necessary nor desirable to build multiple flooding domains. For instance, the flooding optimizations described later this document require a full view of the topology, as does any proposed overlay to inject policy into the forwarding plane. In light of this, the following changes SHOULD BE to IS-IS implemetations to support Openfabric:
Data center network fabrics only contain point-to-point links; because of this, there is no reason to support any broadcast link types, nor to support the Designated Intermediate System processing, including pseudonode creation. In light ot his, processing related to sections 7.2.3 (broadcast networks), 7.3.8 (generation of level 1 pseudonode LSPs), 7.3.10 (generation of level 2 pseudonode LSPs), and section 8.4.5 (LAN designated intermediate systems) in [ISO10589] SHOULD BE removed.
It is important that two way connectivity be established before synchronizing the link state database, or routing through a link in a data center fabric. To reject optical failures that cause a one way connection between two routers, fabricDC must support the three way handshake mechanism described in [RFC5303].
While adjacency formation is not considered particularly burdensome in IS-IS, it may still be useful to reduce the amount of state transferred across the network when connecting a new IS to the fabric. In its simplest form, the process is:
This process allows each IS newly added to the fabric to exchange a full table once; a very minimal amount of information will be transferred with the remaining neighbors to reach full synchronization.
Any such optimization is bound to present a tradeoff between several factors; the mechanism described here increases the amount of time required to form adjacencies slightly in order to reduce the total state carried across the network. An alternative mechanism could provide a better balance of the amount of information carried across the network for initial synchronization and the time required to synchronize a new IS. For instance, an IS could choose to synchronize its database with two or three adjacent intermediate systems, which could speed the synchronization process up at the cost of carrying additional data on the network. A locally determined balance between the speed of synchronization and the amount of data carried on the network can be acheived by adjusting the number of adjacent intermediate systems the newly attached IS synchronizes with.
IS-IS describes the topology in two different sets of TLVs; the first describes the set of neighbors connected to an IS, the second describes the set of reachable destination connected to an IS. There are two different forms of both of these descriptions, one of which carries what are widely called narrow metrics, the other of which carries what are widely called wide metrics. In a tightly controlled data center fabric implementation, such as the ones Openfabric is designed to support, no IS that supports narrow metrics will ever be deployed or supported; hence there is no reason to support any metric type other than wide metrics.
In order to support segment routing, Openfabric needs to be able to support the advertisement of a Prefix-SID tied to a local loopback address assigned to the IS. The configuration of the label to advertise MAY BE manually configured for the moment or determined through autoconfiguration. A Prefix-SID SHOULD BE advertised if a local label is configured using the Prefix Segment Identifier sub-TLV (see section 2.1 of [I-D.ietf-isis-segment-routing-extensions]).
The tier to which a IS is connected is useful to enable autoconfiguration of intermediate systems connected to the fabric and to reduce flooding. Once the tier of an intermediate system within the fabric has been determined, it MUST be advertised using the 4 bit Tier field described in section 3.3 of [I-D.shen-isis-spine-leaf-ext]. This section describes two mechanisms for determining the tier at which a IS is connected in the fabric in several steps.
The first method begins with one of the T0 intermediate systems advertising its location in the fabric. This information can either be obtained through:
The second method above SHOULD be used with care, as it may not be secure, and it may not work in all data center environments. For instance, if a host is mistakenly (or intentionally, as a form of attack) attached to a spine IS, or a request for address assignment is transmitted to a spine IS during the bootup phase of the device or fabric, it is possible to cause a spine IS to advertise itself as a T0. Unless the autodetection of the T0 devices is secured, the manual mechanism SHOULD BE used (configuring at least one T0 device manually).
Given at least one T0 device is advertising its tier number, the remaining intermediate systems calculate their tier number as follows:
In the example network, assume 5A is manually configured as a T0, and is advertising its tier number. From here:
This process will work for any spine and leaf fabric without "cross links."
In some fabrics, it is possible to calculate which intermediate systems are at T0 using a modified Shortest Path First (SPF) calculation. Specifically, if the fabric is configured in five stages, as shown in the example network, and is not some form of butterfly, Benes, or a three stage fabric, it is possible to calcualte if an IS is at T0 using the following process:
If FD == TD, and TD >= 4, this is a greater than three stage fabric; the local device SHOULD advertise 0x00 in its IS reachability tier sub-TLV. For instance, in the diagram above, 1A would:
For the remaining intermediate systems to determine which tier they are situated on, they perform the following calculation:
The IS SHOULD advertise (TD - FD) in its IS reachability tier sub-TLV.
For example, in the above five stage fabric, 3B would:
Flooding is perhaps the most challenging scaling issue for a link state protocol running on a dense, large scale fabric. To reduce the flooding of link state information in the form of Link State Protocol Data Units (LSPs), Openfabric takes advantage of information already available in the link state protocol, the list of the local intermediate system's neighbor's neighbors, and the fabric locality computed above. The following tables are required to compute a set of reflooders:
NL is set to contain all neighbors, and sorted deterministically (for instance, from the highest IS identifier to the lowest). All intermediate systems within a single fabric SHOULD use the same mechanism for sorting the NL list. NN is set to contain all neighbor's neighbors, or all intermediate systems that are two hops away, as determined by performing a truncated SPF. The DNR and RF tables are initially empty. To begin, the following steps are taken to reduce the size of NN and NL:
Then, for every IS in NL:
When flooding, LSPs transmitted to adjacent neighbors on the RF list will be transmitted normally. Adjacent intermediate systems on this list will reflood received LSPs into the next stage of the topology, ensuring database synchronization. LSPs transmitted to adjacent neighbors on the DNR list, however, MUST be transmitted using a circuit scope PDU as described in [RFC7356].
It is possible in some failure modes for flooding to be incomplete because of the flooding optimizations outlined. Specifically, if a reflooder fails, or is somehow disconnected from all the links across which it should be reflooding, it is possible an LSP is only partially flooded through the fabric. To prevent such situations, any IS receiving an LSP transmitted using DNR SHOULD:
In order to reduce the amount of control plane state carried on large scale spine and leaf fabrics, openfabric implementations SHOULD NOT advertise reachability for transit links. These links MAY remain unnumbered, as IS-IS does not require layer 3 IP addresses to operate. Each IS SHOULD be configured with a single loopback address, which is assigned an IPv6 address, to provide reachability to intermediate systems which make up the fabric.
[RFC3277] SHOULD be supported on devices supporting openfabric with unnumbered interface in order to support traceability and network management.
In data center fabrics, ToR intermediate systems SHOULD NOT be used to transit between two T1 (or above) spine intermediate systems. The simplest way to prevent this is to set the overload bit for all the LSPs originated from T0 intermediate systems. However, this solution would have the unfortunate side effect of causing all reachability beyond any T0 IS to have the same metric, and many implementations treat a set overload bit as a metric of 0xFFFF in calculating the Shortest Path Tree (SPT). This document proposes an alternate solution which preserves the leaf node metric, while still avoiding transiting T0 intermediate systems.
Specifically, all T0 intermediate systems SHOULD advertise their metric to reach any T1 adjacent neighbor with a cost of 0XFFE. T1 intermediate systems, on the other hand, will advertise T0 intermediate systems with the actual interface cost used to reach the T0 IS. Hence, links connecting T0 and T1 intermediate systems will be advertised with an asymmetric cost that discourages transiting T0 intermediate systems, while leaving reachability to the destinations attached to T0 devices the same.
While schemes may be designed so reachability information can be aggregated in Openfabric deployments, this is not a recommended configuraiton.
This document outlines modifications to the IS-IS protocol for operation on large scale data center fabrics. While it does add new TLVs, and some local processing changes, it does not add any new security vulnerabilities to the operation of IS-IS. However, openfabric implementations SHOULD implement IS-IS cryptographic authentication, as described in [RFC5304], and should enable other security measures in accordance with best common practices for the IS-IS protocol.
If T0 intermediate systems are auto-detected using information outside Openfabric, it is possible to attack the calucations used for flooding reduction and auto-configuration of intermediate systems. For instance, if a request for an address pool is used as an indicator of an attached host, and hence receiving such a request causes an intermediate system to advertise itself as T0, it is possible for an attacker (or a simple mistake) to cause auto-configuration to fail. Any such auto-detection mechanims SHOULD BE secured using appropriate techniques, as described by any protocols or mechanisms used.