Internet DRAFT - draft-blumenau-fcmgmt-int-mib
draft-blumenau-fcmgmt-int-mib
INTERNET-DRAFT FC Mgmt Integration MIB June 1, 1999
<draft-blumenau-fcmgmt-int-mib-01.txt> S. Blumenau
(expires December 1, 1999) (EMC Corporation)
Fibre Channel Management Framework Integration MIB
Status of this Memo:
This document is an Internet-Draft and is in full conformance with
all provisions of Section 10 of RFC2026.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF), its areas, and its working groups. Note that
other groups may also distribute working documents as
Internet-Drafts.
Internet-Drafts are draft documents valid for a maximum of six
months and may be updated, replaced, or obsoleted by other documents
at any time. It is inappropriate to use Internet-Drafts as
reference material or to cite them other than as "work in progress."
The list of current Internet-Drafts can be accessed at
http://www.ietf.org/ietf/1id-abstracts.txt
The list of Internet-Draft Shadow Directories can be accessed at
http://www.ietf.org/shadow.html.
Abstract:
The goal of this document is to fill in missing pieces necessary
to enable an enterprise class storage network. One of the more
important features of an enterprise class storage network is
management; this document gives a framework MIB that will provide
an integrated management environment for the enterprise customer.
An enterprise class storage network is comprised of elements
(i.e., hubs, switches, converters, gateways, and HBAs) that are
developed by many different vendors. The large number of vendors
that can exist in a storage network makes mangement a very hard
and complicated problem. The main goal of this document's MIB is
to enable interoperability among the various vendors involved in
the Fibre Channel marketplace.
Acknowledgements:
The following companies have contributed to the creation of this
specification:
o Ancor Communications
o ATTO Technology, Inc.
o Crossroads Systems, Inc.
o EMC Corporation
o Emulex Corporation
Blumenau [Page 01]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
o G2 Networks
o Gadzoox Networks, Inc.
o Hewlett Packard Co.
o Interphase Corporation
o Jaycor Networks Inc.
o Legato Systems, Inc.
o McData Corporation
o Prisa Networks, Inc.
o QLogic Corporation
o Siemens AG
o Sterling Software, Inc.
o Storage Networking Industry Association
o StorageNetworks, Inc.
o Transoft Networks, Inc.
o VERITAS Software Corporation
o Vixel Corporation
The MIB:
FCMGMT-MIB
DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, TimeTicks, experimental
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
TRAP-TYPE
FROM RFC-1215;
FcNameId ::= OCTET STRING (SIZE(8))
fcmgmt OBJECT IDENTIFIER ::= { experimental 94 }
-- groups in fcmgmt
connSet OBJECT IDENTIFIER ::= { fcmgmt 1 }
trapReg OBJECT IDENTIFIER ::= { fcmgmt 2 }
revisionNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (4))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the revision number for this MIB. The
format of the revision value is as follows
(0) = high order major revision number
(1) = low order major revision number
(2) = high order minor revision number
(3) = low order minor revision number
Blumenau [Page 02]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
The value will be stored as an ASCII value. The
following is the current values.
(0) = '0'
(1) = '1'
(2) = '5'
(3) = '0'
This defines a revision of 1.5
"
::= { fcmgmt 3 }
-- the connectivity unit group
-- Implementation of the group is mandatory for all systems.
uNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of connectivity units present on this
system. This is used to identify the number of
boards in a chassis or the number of full boxes
in a rack."
DEFVAL { 1 }
::= { connSet 1 }
systemURL OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The top-level URL of the system. If does not exist
the value is empty string."
DEFVAL { "" }
::= { connSet 2 }
statusChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the last status change occurred for any members of
the set. This represents a union of change
information for connUnitStatusChangeTime."
::= { connSet 3 }
configurationChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
Blumenau [Page 03]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
the last configuration change occurred for any
members of the set. This represents a union of change
information for connUnitConfigurationChangeTime."
::= { connSet 4 }
connUnitTableChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the connUnitTable was updated (an entry was either
added or deleted."
::= { connSet 5 }
-- The Connectivity table contains general information on the
-- system's units.
connUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of units under a single SNMP agent. The
number of entries is given by the value of uNumber.
It is 1 for stand-alone system."
::= { connSet 6 }
connUnitEntry OBJECT-TYPE
SYNTAX ConnUnitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A connectivity unit entry containing objects
for a particular unit."
INDEX { connUnitId }
::= { connUnitTable 1 }
ConnUnitEntry ::=
SEQUENCE {
connUnitId
OCTET STRING,
connUnitGlobalId
OCTET STRING,
connUnitType
INTEGER,
connUnitNumports
INTEGER,
connUnitState
INTEGER,
connUnitStatus
INTEGER,
connUnitProduct
DisplayString,
Blumenau [Page 04]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitSn
DisplayString,
connUnitUpTime
TimeTicks,
connUnitUrl
DisplayString,
connUnitDomainId
OCTET STRING,
connUnitProxyMaster
INTEGER,
connUnitPrincipal
INTEGER,
connUnitNumSensors
INTEGER,
connUnitStatusChangeTime
TimeTicks,
connUnitConfigurationChangeTime
TimeTicks,
connUnitNumRevs
INTEGER,
connUnitNumZones
INTEGER,
connUnitModuleId
OCTET STRING,
connUnitName
DisplayString,
connUnitInfo
DisplayString,
connUnitControl
INTEGER,
connUnitContact
OCTET STRING,
connUnitLocation
OCTET STRING
}
connUnitId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The goal is to create a locally unique Id
space for all connUnitIds within this proxy
domain. It is left up to the vendor to
generate the unique IDs. It is a goal that
the value is kept constant between boots.
It is also a goal that the relationship
be retained between the connUnitId and the
connUnitGlobalId if the connUnitGlobalId is
non-zero."
::= { connUnitEntry 1 }
Blumenau [Page 05]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitGlobalId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The goal is to create a globally unique Id
space for all connUnitGlobalIds. This is a
set of hex bytes, not ASCII.
connUnitGlobalId is a
WWN, including the leading NAA, in any FC-PH
authorized format. This requires that you
have to have an IEEE OUI (vendor id) to assign
connUnitGlobalId. Once you have supplied the
NAA and OUI, you as a vendor are completely
free as to how you assign the rest of the bits,
as long as you assure they are unique. There
is some merit, though not a requirement, that
the WWN used as connUnitGlobalId be the same
as that of (one of) the permanently attached
FC/LAN interface(s). Whether it is or not,
it must be unique. As an example, if your
agent runs in a host and the host has an HBA,
it is quite possible that agent, host, and HBA
will all be distinct connUnits, so the host
and agent can not use the WWN of the HBA.
Another example:
If your hub has a built-in Ethernet port, it
might be reasonable for the hub to use its LAN
address (prefixed with the with appropriate
NAA) as its connUnitGlobalId. But if the
Ethernet was a replaceable PCCard, the hub
should have an independent ID. If the global
ID is not known then this object is set to
all zeros. When this value is found by a
management station, it will indicate that
information about it should not be trusted
to be correct. The following are some
references for more information.
http://standards.ieee.org/regauth/oui/tutorials/fibreformat.html
http://standards.ieee.org/regauth/oui/tutorials/fibrecomp_id.html"
::= { connUnitEntry 2 }
connUnitType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2), -- none of the following
hub(3),
switch(4),
gateway(5),
converter(6),
hba(7),
proxy-agent(8),
Blumenau [Page 06]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
storage-device(9), -- disk,cd,tape,etc
host(10),
storage-subsystem(11), -- raid, library, etc
module(12),
swdriver(13)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of the FC connectivity unit."
::= { connUnitEntry 3 }
connUnitNumports OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of physical FC ports in the unit
(internal/embedded, external)."
::= { connUnitEntry 4 }
connUnitState OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
online(2),
offline(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Overall state of the connectivity unit."
::= { connUnitEntry 5 }
connUnitStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
unused(2),
ok(3),
warning(4), -- needs attention
failed(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Overall status of the connectivity unit."
::= { connUnitEntry 6 }
Blumenau [Page 07]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitProduct OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..79))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connectivity unit vendor's product
model name."
::= { connUnitEntry 7 }
connUnitSn OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..79))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number for this unit. A
permanent unique identifier defined by
the vendor."
::= { connUnitEntry 8 }
connUnitUpTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of centiseconds since the
last unit initialization."
::= { connUnitEntry 9 }
connUnitUrl OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"URL to launch management application,
if applicable. Otherwise empty string.
In a standalone unit, this would be the
same as the top-level URL."
::= { connUnitEntry 10 }
connUnitDomainId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"24 bit ID, right justified, unique within
the Fabric address domain. If this value
is not applicable, return all bits set to one."
::= { connUnitEntry 11 }
Blumenau [Page 08]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitProxyMaster OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a yes if this is the proxy master
unit for a set of managed units. For example,
this could be the only unit with a management
card in it for a set of units. If this is a
standalone unit, then this is set to 'yes'."
::= { connUnitEntry 12 }
connUnitPrincipal OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
no(2),
yes(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Whether the unit is the principal unit
within the fabric domain. If this value
is not applicable, return unknown."
::= { connUnitEntry 13 }
connUnitNumSensors OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of sensors in the unit."
::= { connUnitEntry 14 }
connUnitStatusChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds
at which the last status change occurred."
::= { connUnitEntry 15 }
connUnitConfigurationChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds
at which last configuration change occurred."
::= { connUnitEntry 16 }
Blumenau [Page 09]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitNumRevs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of revisions in the revision
table."
DEFVAL { 1 }
::= { connUnitEntry 17 }
connUnitNumZones OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of zones defined in the zone table."
::= { connUnitEntry 18 }
connUnitModuleId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a unique id that does not need to
be persistent between boots. It is used
to group a set of modules together into
a single connUnit. The intended use would
be to create a connUnit with a type of
module and then set it's moduleid to its
connUnitId. All other connUnits that are
part of the module will have the same
module id as the container. This should
be 16 zeros if it is not used."
::= { connUnitEntry 19 }
connUnitName OBJECT-TYPE
SYNTAX DisplayString (SIZE(40))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A display string containing a name for this
unit. This item should be persistent across
coldstarts."
::= { connUnitEntry 20 }
connUnitInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE(256))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A display string containing comments such
as comments on this unit. This item should be
persistent across coldstarts."
::= { connUnitEntry 21 }
Blumenau [Page 10]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitControl OBJECT-TYPE
SYNTAX INTEGER {
resetConnUnitColdStart(1),
resetConnUnitWarmStart(2),
offlineConnUnit(3),
onlineConnUnit(4)
}
ACCESS read-write -- (or maybe write-only)
STATUS mandatory
DESCRIPTION
"This object is used to control the addressed
connUnit. Valid commands are:
resetConnUnitColdStart: If the addressed
connUnit allows this operation to be performed
to this MIB object, the addressed unit performs
a 'Cold Start' reset.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
resetConnUnitWarmStart: If the addressed
connUnit allows this operation to be performed
to this MIB object, the addressed unit performs
a 'Warm Start' reset.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
offlineConnUnit: If the addressed connUnit
allows this operation to be performed to this
MIB object, the addressed unit puts itself into
a vendor-specific 'offline' state. In general,
if a unit is in an offline state, it cannot be
used to perform meaningful Fibre Channel work.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
onlineConnUnit: If the addressed connUnit
allows this operation to be performed to this
MIB object, the addressed unit puts itself into
a vendor-specific 'online' state. In general,
if a unit is in an online state, it is capable
of performing meaningful Fibre Channel work.
Blumenau [Page 11]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
For any other value set to this object, the
addressed unit sends back a 'bad value' SNMP
response to the SNMP set request."
::= { connUnitEntry 22 }
connUnitContact OBJECT-TYPE
SYNTAX OCTET STRING -- note: the size of this
-- string is intentionally
-- left undefined
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the addressed connUnit allows sets to be
done to this object, this MIB object behaves
in a similar manner to the MIB2 'sysContact'
object. If the size of the octet string is
larger than the addressed connUnit can support,
the addressed unit sends back a 'tooBig' SNMP
response to the SNMP set request.
If the addressed connUnit does not allow writes
to this object, the addressed unit sends back
a 'generic error' SNMP response to the SNMP
set request. The addressed unit may also return
a null string in response to an SNMP get
request for this object."
::= { connUnitEntry 23 }
connUnitLocation OBJECT-TYPE
SYNTAX OCTET STRING -- note: the size of this
-- string is intentionally
-- left undefined
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the addressed connUnit allows sets to be
done to this object, this MIB object behaves
in a similar manner to the MIB2 'sysLocation'
object. If the size of the octet string is
larger than the addressed connUnit can support,
the addressed unit sends back a 'tooBig' SNMP
response to the SNMP set request.
If the addressed connUnit does not allow writes
to this object, the addressed unit sends back a
'generic error' SNMP response to the SNMP
Blumenau [Page 12]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
set request. The addressed unit may also
return a null string in response to an SNMP
get request for this object."
::= { connUnitEntry 24 }
-- The Table of revisions for hardware and software elements.
connUnitRevsTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitRevsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of the revisions supported by the system."
::= { connSet 7 }
connUnitRevsEntry OBJECT-TYPE
SYNTAX ConnUnitRevsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { connUnitRevsUnitId,
connUnitRevsIndex }
::= { connUnitRevsTable 1 }
ConnUnitRevsEntry ::=
SEQUENCE {
connUnitRevsUnitId
OCTET STRING,
connUnitRevsIndex
INTEGER,
connUnitRevsFirmRev
DisplayString,
connUnitRevsDescription
DisplayString
}
connUnitRevsUnitId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is identical to connUnitId."
::= { connUnitRevsEntry 1 }
connUnitRevsIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value in the range between 1 and
connUnitNumRevs."
::= { connUnitRevsEntry 2 }
Blumenau [Page 13]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitRevsFirmRev OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The firmware of the unit."
::= { connUnitRevsEntry 3 }
connUnitRevsDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of a component to which the firmware
corresponds."
::= { connUnitRevsEntry 4 }
-- The Sensor table
connUnitSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitSensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Description of each Sensor for a specific
connUnit."
::= { connSet 8 }
connUnitSensorEntry OBJECT-TYPE
SYNTAX ConnUnitSensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the information for a
specific Sensor."
INDEX { connUnitSensorUnitId,
connUnitSensorIndex }
::= { connUnitSensorTable 1 }
ConnUnitSensorEntry ::=
SEQUENCE {
connUnitSensorUnitId
OCTET STRING,
connUnitSensorIndex
INTEGER (1..2147483647),
connUnitSensorName
DisplayString,
connUnitSensorStatus
INTEGER,
connUnitSensorInfo
DisplayString,
connUnitSensorMessage
DisplayString
}
Blumenau [Page 14]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitSensorUnitId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is identical to connUnitId."
::= { connUnitSensorEntry 1 }
connUnitSensorIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each sensor. Its value
ranges between 1 and the value of
connUnitNumSensors."
::= { connUnitSensorEntry 2}
connUnitSensorName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This describes a sensor in the unit."
::= { connUnitSensorEntry 3 }
connUnitSensorStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2),
warning(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the status for the sensor."
::= { connUnitSensorEntry 4 }
connUnitSensorInfo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This describes misc info about the sensor
such as its serial number."
::= { connUnitSensorEntry 5 }
Blumenau [Page 15]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitSensorMessage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This describes the status of the sensor
as a message."
::= { connUnitSensorEntry 6 }
-- The Zone table (still under discussion)
connUnitZoneTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitZoneEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Description of each Zone for a specific
connUnit."
::= { connSet 9 }
connUnitZoneEntry OBJECT-TYPE
SYNTAX ConnUnitZoneEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the information for a
specific Zone."
INDEX { connUnitZoneUnitId,
connUnitZoneIndex,
connUnitZoneMemberIndex }
::= { connUnitZoneTable 1 }
ConnUnitZoneEntry ::=
SEQUENCE {
connUnitZoneUnitId
OCTET STRING,
connUnitZoneIndex
INTEGER (1..2147483647),
connUnitZoneMemberIndex
INTEGER (1..2147483647),
connUnitZoneNumMember
INTEGER,
connUnitZoneName
DisplayString,
connUnitZoneStatus
INTEGER
}
Blumenau [Page 16]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitZoneUnitId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is identical to connUnitId."
::= { connUnitZoneEntry 1 }
connUnitZoneIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each zone. Its value
ranges between 1 and the value of
connUnitNumZones."
::= { connUnitZoneEntry 2}
connUnitZoneMemberIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each member of a zone.
Its value ranges between 1 and the value of
connUnitZoneNumMember."
::= { connUnitZoneEntry 3}
connUnitZoneNumMember OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of members in this zone."
::= { connUnitZoneEntry 4}
connUnitZoneName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This describes a zone in the unit."
::= { connUnitZoneEntry 5 }
Blumenau [Page 17]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitZoneStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2),
warning(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the status for the zone."
::= { connUnitZoneEntry 6 }
-- The port table
connUnitPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Generic information on ports for a specific
connUnit."
::= { connSet 10 }
connUnitPortEntry OBJECT-TYPE
SYNTAX ConnUnitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the information for
a specific port. The entry corresponds to
the connectivity unit index by connUnitId."
INDEX { connUnitPortUnitId,
connUnitPortIndex }
::= { connUnitPortTable 1 }
ConnUnitPortEntry ::=
SEQUENCE {
connUnitPortUnitId
OCTET STRING,
connUnitPortIndex
INTEGER (1..2147483647),
connUnitPortType
INTEGER,
connUnitPortClassCap
OCTET STRING,
connUnitPortClassOp
OCTET STRING,
connUnitPortState
INTEGER,
connUnitPortStatus
INTEGER,
Blumenau [Page 18]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitPortConnector
INTEGER,
connUnitPortModuleType
INTEGER,
connUnitPortWwn
FcNameId,
connUnitPortConnId
OCTET STRING,
connUnitPortTxFrames
OCTET STRING,
connUnitPortRxFrames
OCTET STRING,
connUnitPortSn
DisplayString,
connUnitPortRevision
DisplayString,
connUnitPortVendor
DisplayString,
connUnitPortSpeed
INTEGER,
connUnitPortControl
INTEGER,
connUnitPortName
OCTET STRING
}
connUnitPortUnitId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is identical to connUnitId."
::= { connUnitPortEntry 1 }
connUnitPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each port. Its value
ranges between 1 and the value of
connUnitNumports."
::= { connUnitPortEntry 2 }
Blumenau [Page 19]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitPortType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
hub-port(3),
n-port(4), -- end port for fabric
l-port(5), -- end port for loop
fl-port(6), -- public loop
f-port(7), -- fabric port
e-port(8), -- fabric expansion port
domain-ctl(9), -- domain controller
hub-controller(10),
scsi(11), -- parallel SCSI port
escon(12),
lan(13),
wan(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identification of the port type."
::= { connUnitPortEntry 3 }
connUnitPortClassCap OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bit mask that specifies the classes
of service capabilities. If this is not
applicable, return all bits set to zero.
The bits are set right justified and have
the following definition:
unknown(0)
class-f(1)
class-one(2)
class-two(4)
class-three(8)
class-four(16)
class-five(32)
class-six(64)"
::= { connUnitPortEntry 4 }
connUnitPortClassOp OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bit mask that specifies the classes
of service that are currently operational.
If this is not applicable, return all bits
Blumenau [Page 20]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
set to zero. The bits are set right-
justified and have the following definition:
unknown(0)
class-f(1)
class-one(2)
class-two(4)
class-three(8)
class-four(16)
class-five(32)
class-six(64)"
::= { connUnitPortEntry 5 }
connUnitPortState OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
online(2),
offline(3),
bypassed(4),
linkdown(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This represents the state of the port
protocol."
::= { connUnitPortEntry 6 }
connUnitPortStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
unused(2),
ok(3),
warning(4), -- needs attention
failure(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An overall hardware status for the
port."
::= { connUnitPortEntry 7 }
connUnitPortConnector OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
unused(3),
shortwave(4),
longwave(5),
copper(6),
scsi(7)
}
Blumenau [Page 21]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The technology of the connector."
::= { connUnitPortEntry 8 }
connUnitPortModuleType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
gbic(3),
embedded(4), -- fixed, ie, oneXnine
glm(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The module type of the port connector."
::= { connUnitPortEntry 9 }
connUnitPortWwn OBJECT-TYPE
SYNTAX FcNameId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The World Wide Name of the port
if applicable, otherwise empty string."
REFERENCE
"See FC elements MIB for FcNameId definition."
::= { connUnitPortEntry 10 }
connUnitPortConnId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the Fibre Channel ID of this port.
It only has a meaning if the connectivity
unit is a switch. This is expected to be
a Big Endian value of 24 bits. If not
supported, return all bits set to 1."
::= { connUnitPortEntry 11 }
connUnitPortTxFrames OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count of the frames that have been
sent from this port. This is expected to
be a Big Endian value. If not applicable,
return all bits set to zero."
::= { connUnitPortEntry 12 }
Blumenau [Page 22]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitPortRxFrames OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count of the frames that have been
received by this port. This is expected to
be a Big Endian value. If not applicable,
return all bits set to zero."
::= { connUnitPortEntry 13 }
connUnitPortSn OBJECT-TYPE
SYNTAX DisplayString (SIZE(79))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number of the unit (e.g., for
a GBIC). If this is not applicable, return
empty string."
::= { connUnitPortEntry 14 }
connUnitPortRevision OBJECT-TYPE
SYNTAX DisplayString (SIZE(79))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port revision (e.g., for a GBIC)."
::= { connUnitPortEntry 15 }
connUnitPortVendor OBJECT-TYPE
SYNTAX DisplayString (SIZE(79))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port vendor (e.g., for a GBIC)."
::= { connUnitPortEntry 16 }
connUnitPortSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The speed of the port in megabyes per
second."
::= { connUnitPortEntry 17 }
connUnitPortControl OBJECT-TYPE
SYNTAX INTEGER {
resetConnUnitPort(1),
bypassConnUnitPort(2),
unbypassConnUnitPort(3),
offlineConnUnitPort(4),
onlineConnUnitPort(5)
}
Blumenau [Page 23]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
ACCESS read-write -- (or maybe write-only)
STATUS mandatory
DESCRIPTION
"This object is used to control the addressed
connUnit's port. Valid commands are:
resetConnUnitPort: If the addressed connUnit
allows this operation to be performed to this
port, the addressed port performs a
vendor-specific 'reset' operation. Examples of
these operations are: the Link Reset protocol,
the Loop Initialization protocol, or a
resynchronization occurring between the
transceiver in the addressed port to the
transceiver that the port is connected to.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
bypassConnUnitPort: If the addressed connUnit
allows this operation to be performed to this
port, the addressed port performs a
vendor-specific 'bypass' operation. Examples of
these operations are:
the Online to Offline protocol, a
request(NON-PARTICIPATING) command to the
Loop Port state machine, or removal of the
port from an arbitrated loop by a hub.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
unbypassConnUnitPort: If the addressed connUnit
allows this operation to be performed to this
port, the addressed port performs a
vendor-specific 'unbypass' operation. Examples
of these operations are:
the Link Failure protocol, a
request(PARTICIPATING) command to the
Loop Port state machine, or addition of the
port to an arbitrated loop by a hub.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
Blumenau [Page 24]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
offlineConnUnitPort: If the addressed connUnit
allows this operation to be performed to this
port, the addressed port performs a
vendor-specific 'offline' operation. Examples
of these operations are:
disabling a port's transceiver, the Link
Failure protocol, request(NON-PARTICIPATING)
command to the Loop Port state machine, or
removal of the port from an arbitrated loop
by a hub.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
onlineConnUnitPort: If the addressed connUnit
allows this operation to be performed to this
port, the addressed port performs a
vendor-specific 'online' operation. Examples
of these operations are:
enabling a port's transceiver, the Link
Failure protocol, request(PARTICIPATING)
command to the Loop Port state machine, or
addition of the port from an arbitrated loop
by a hub.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request."
::= { connUnitPortEntry 18 }
connUnitPortName OBJECT-TYPE
SYNTAX OCTET STRING -- note: the size of this
-- string is intentionally
-- left undefined
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the addressed connUnit allows sets to be
done to this object, this MIB object can be
used to store a string describing the
addressed port. If the size of the octet
string is larger than the addressed connUnit
can support, the addressed unit sends back a
'tooBig' SNMP response to the SNMP set request.
If the addressed connUnit does not allow writes
to this object, the addressed unit sends back
a 'generic error' SNMP response to the SNMP
set request. The addressed unit may also
return a null string in response to an SNMP
get request for this object."
::= { connUnitPortEntry 19 }
Blumenau [Page 25]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
-- event group
connUnitEventTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitEventEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of connectivity unit events. Only errors,
warnings, and information (not debugging) should be
reported in this table."
::= { connSet 11 }
connUnitEventEntry OBJECT-TYPE
SYNTAX ConnUnitEventEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains information on
a specific event for the given
connectivity unit."
INDEX { connUnitEventUnitId, connUnitEventIndex }
::= { connUnitEventTable 1 }
ConnUnitEventEntry ::=
SEQUENCE {
connUnitEventUnitId
OCTET STRING,
connUnitEventIndex
INTEGER (1..2147483647),
connUnitEventId
INTEGER,
connUnitREventTime
DisplayString,
connUnitSEventTime
TimeTicks,
connUnitEventSeverity
INTEGER,
connUnitEventType
INTEGER,
connUnitEventObjectIndex
INTEGER,
connUnitEventDescr
DisplayString,
connUnitEventFilter
INTEGER
}
connUnitEventUnitId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is identical to connUnitId."
::= { connUnitEventEntry 1 }
Blumenau [Page 26]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitEventIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique event index. It ranges
between 1 and the size of the event table
for the connectivity unit. It wraps on
itself when the end of allocated space
is reached."
::= { connUnitEventEntry 2 }
connUnitEventId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique event Id. Incremented for each
event. Not used as table index to simplify
the agent implementation. If there is a gap
in the values, then it can be assumed that
events have been deleted before read."
::= { connUnitEventEntry 3 }
connUnitREventTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the real time when the event occurred.
It has the following format.
DDMMYYYY HHMMSS
DD=day number
MM=month number
YYYY=year number
HH=hour number
MM=minute number
SS=seconds number
If not applicable, return a NULL string."
::= { connUnitEventEntry 4 }
connUnitSEventTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the sysuptime timestamp when the
event occurred."
::= { connUnitEventEntry 5 }
Blumenau [Page 27]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitEventSeverity OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
informational(3),
warning(4),
critical(5),
failure(6),
init(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The event severity."
::= { connUnitEventEntry 6 }
connUnitEventType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
status(3),
configuration(4),
topology(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of event that has occurred."
::= { connUnitEventEntry 7 }
connUnitEventObjectIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is used with the connUnitEventType
to identify which object."
::= { connUnitEventEntry 8 }
connUnitEventDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The description of the event."
::= { connUnitEventEntry 9 }
Blumenau [Page 28]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitEventFilter OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
informational(3),
warning(4),
critical(5),
failure(6),
init(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value defines the event severity
that will be generated. It records all
events that are greater than or equal to
the value that is set."
::= { connUnitEventEntry 10 }
-- The link table (still under discussion)
connUnitLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitLinkTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of links from this proxy domain to other
(vendors') proxy domains."
::= { connSet 12 }
connUnitLinkNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of links to other (vendors') proxy domains
found. A 0 value indicates no links are present."
::= { connSet 13 }
connUnitLinkTableEntry OBJECT-TYPE
SYNTAX ConnUnitLinkTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry describing a particular link to another
(vendor's) proxy domain."
INDEX { connUnitLinkTableId }
::= { connUnitLinkTable 1 }
Blumenau [Page 29]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
ConnUnitLinkTableEntry ::=
SEQUENCE {
connUnitLinkTableId
OCTET STRING,
connUnitlocalUnitNodeId
OCTET STRING,
connUnitlocalUnitPortNumber
INTEGER,
connUnitremoteUnitNodeId
OCTET STRING,
connUnitremoteUnitPortId
OCTET STRING
}
connUnitLinkTableId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is identical to connUnitId."
::= { connUnitLinkTableEntry 1 }
connUnitlocalUnitNodeId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node identifier (eg, WWN) of the unit
within our local proxy domain that is
connected to this particular link. If this
link does not have a WWN then use serial
number or some other unique id for the
unit."
::= { connUnitLinkTableEntry 2 }
connUnitlocalUnitPortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number on the unit specified by
connUnitlocalUnitNodeId that is connected
to this particular link. A value of 0 in
this object indicates that it is not known
which port on the device specified by
connUnitlocalUnitNodeId is connected to this
particular link. A non-zero value specifies
a valid (local) port number that is connected
to this particular link."
::= { connUnitLinkTableEntry 3 }
Blumenau [Page 30]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
connUnitremoteUnitNodeId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node identifier (eg, WWN) of the device
within the remote proxy domain that is
connected to this particular link. If this
link does not have a WWN then use serial
number or some other unique id for the
unit."
::= { connUnitLinkTableEntry 4 }
connUnitremoteUnitPortId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port identifier (eg, WWN) of the port
within the remote proxy domain that is
connected to this particular link. Note
that this may be the same value as
connUnitremoteUnitNodeId or it may be 0.
Both of these values indicate there is no
unique port WWN associated with the remote
port. If this link does not have a WWN then
use serial number or some other unique id for
the unit."
::= { connUnitLinkTableEntry 5 }
-- SNMP trap registration group
trapMaxClients OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of SNMP trap recipients
supported by the system."
::= { trapReg 1 }
trapClientCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current number of rows in the trap table."
::= { trapReg 2 }
Blumenau [Page 31]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
trapRegTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapRegEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing a row for each IP address/port
number that traps will be sent to."
::= { trapReg 3 }
trapRegEntry OBJECT-TYPE
SYNTAX TrapRegEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Ip/Port pair for a specific client."
INDEX { trapRegIpAddress,
trapRegPort }
::= { trapRegTable 1 }
TrapRegEntry ::=
SEQUENCE {
trapRegIpAddress
IpAddress,
trapRegPort
INTEGER (1..2147483647),
trapRegFilter
INTEGER,
trapRegRowState
INTEGER
}
trapRegIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Ip address of a client registered for
traps. If the addressed connUnit does not allow
writes to this object, addressed unit sends back a
'generic error' SNMP response to the set request."
::= { trapRegEntry 1 }
trapRegPort OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This contains the value of the UDP port that
is in use. If the addressed connUnit does not allow
writes to this object, addressed unit sends back a
'generic error' SNMP response to the set request."
::= { trapRegEntry 2 }
Blumenau [Page 32]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
trapRegFilter OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
informational(3),
warning(4),
critical(5),
failure(6),
init(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value defines the trap severity
that will be generated. It generates all
traps that are greater than or equal to
the value that is set. If the addressed connUnit
does not allow writes to this object, addressed
unit sends back a 'generic error' SNMP response
to the set request. The default value of this
object is warning."
::= { trapRegEntry 3}
trapRegRowState OBJECT-TYPE
SYNTAX INTEGER {
rowDestroy(1), -- Remove row from table.
rowInactive(2), -- Row exists, but TRAPs disabled
rowActive(3) -- Row exists and is enabled for
-- sending traps
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the state of the row.
rowDestroy
READ: Can never happen.
WRITE: Remove this row from the table.
rowInactive
READ: Indicates that this row does exists, but
that TRAPs are not enabled to be sent to
the target.
WRITE: If the row does not exist, and the
agent allows writes to the trap table,
then a new row is created. The values
of the optional columns will be set to
default values. TRAPS are not enabled
to be sent to the target. If the row
already existed, then TRAPs are disabled
from being sent to the target.
rowActive
READ: Indicates that this row exists, and that
TRAPs are enabled to be sent to the target.
Blumenau [Page 33]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
WRITE: If the row does not exist, and the agent
allows writes to the trap table, then a new
row is created. The values of the optional
columsn will be set to default values. TRAPs
are enabled to be sent to the target. If
the row alreadt existed, then TRAPs
are enabled to be sent to the target."
::= { trapRegEntry 4}
-- Related traps
connUnitStatusChange TRAP-TYPE
ENTERPRISE fcmgmt
VARIABLES { connUnitStatusChangeTime
}
DESCRIPTION
"The overall status of the connectivity unit has
changed."
::= 1
connUnitAddedTrap TRAP-TYPE
ENTERPRISE fcmgmt
VARIABLES { connUnitId
}
DESCRIPTION
"An event is generated when an entry is added to
the connUnitTable."
::= 2
connUnitDeletedTrap TRAP-TYPE
ENTERPRISE fcmgmt
VARIABLES { connUnitId
}
DESCRIPTION
"An event is generated when an entry is deleted
from the connUnitTable."
::= 3
connUnitEventTrap TRAP-TYPE
ENTERPRISE fcmgmt
VARIABLES { connUnitEventId,
connUnitEventType,
connUnitEventObjectIndex,
connUnitEventDescr }
DESCRIPTION
"An event has been generated by the
connectivity unit."
::= 4
END
Blumenau [Page 34]
INTERNET-DRAFT FC-Mgmt-Int MIB June 1, 1999
Author Contact Information:
Steven Blumenau
EMC Corporation
171 South Street
Hopkinton, MA 01748-9103
USA
Phone: 1-508-435-1000 x4657
E-mail: blumenau_steven@isus.emc.com
(This draft expires December 1, 1999.)
Blumenau [Page 35]