Internet Engineering Task Force L. Avramov
Internet-Draft, Intended status: Informational Cisco Systems
Expires: April 20, 2015 J. Rapp
October 17, 2014 Hewlett-Packard
Data Center Benchmarking Definitions and Metrics
draft-dcbench-def-02
Abstract
The purpose of this informational document is to establish definitions,
discussion and measurement techniques for data center benchmarking.
Also, it is to introduce new terminologies applicable to data center
performance evaluations. The purpose of this document is not to define
the test methodology, but rather establish the important concepts when
one is interested in benchmarking network equipment in the data center.
Status of this Memo
This Internet-Draft is submitted in full conformance with the provisions
of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering Task
Force (IETF), its areas, and its working groups. Note that other groups
may also distribute working documents as Internet-Drafts.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference material
or to cite them other than as "work in progress."
The list of current Internet-Drafts can be accessed at
http://www.ietf.org/1id-abstracts.html
The list of Internet-Draft Shadow Directories can be accessed at
http://www.ietf.org/shadow.html
Copyright Notice
Copyright (c) 2013 IETF Trust and the persons identified as the document
authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal Provisions
Relating to IETF Documents (http://trustee.ietf.org/license-info) in
effect on the date of publication of this document. Please review these
Avramov & Rapp Expires April 20, 2015 [Page 1]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
documents carefully, as they describe your rights and restrictions with
respect to this document. Code Components extracted from this document
must include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1. Requirements Language . . . . . . . . . . . . . . . . . . 4
1.2. Definition format . . . . . . . . . . . . . . . . . . . . . 4
2. Latency . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1. Definition . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.3 Measurement Units . . . . . . . . . . . . . . . . . . . . . 5
3 Jitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.1 Definition . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.2 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.3 Measurement Units . . . . . . . . . . . . . . . . . . . . . 6
4 Physical Layer Calibration . . . . . . . . . . . . . . . . . . . 6
4.1 Definition . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.2 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.3 Measurement Units . . . . . . . . . . . . . . . . . . . . . 7
5 Line rate . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.1 Definition . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.2 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . 8
5.3 Measurement Units . . . . . . . . . . . . . . . . . . . . . 9
6 Buffering . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.1 Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.1.1 Definition . . . . . . . . . . . . . . . . . . . . . . . 10
6.1.3 Discussion . . . . . . . . . . . . . . . . . . . . . . . 11
6.1.3 Measurement Units . . . . . . . . . . . . . . . . . . . 11
6.2 Incast . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.2.1 Definition . . . . . . . . . . . . . . . . . . . . . . . 12
6.2.2 Discussion . . . . . . . . . . . . . . . . . . . . . . . 12
6.2.3 Measurement Units . . . . . . . . . . . . . . . . . . . 13
7 Application Throughput: Data Center Goodput . . . . . . . . . . 13
7.1. Definition . . . . . . . . . . . . . . . . . . . . . . . . 13
7.2. Discussion . . . . . . . . . . . . . . . . . . . . . . . . 13
7.3. Measurement Units . . . . . . . . . . . . . . . . . . . . . 13
8. References . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.1. Normative References . . . . . . . . . . . . . . . . . . . 14
3.2. Informative References . . . . . . . . . . . . . . . . . . 14
3.3. URL References . . . . . . . . . . . . . . . . . . . . . . 14
3.4. Acknowledgments . . . . . . . . . . . . . . . . . . . . . 15
Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . . 15
Avramov & Rapp Expires April 20, 2015 [Page 2]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
1. Introduction
Traffic patterns in the data center are not uniform and are contently
changing. They are dictated by the nature and variety of applications
utilized in the data center. It can be largely east-west traffic
flows in one data center and north-south in another, while some may
combine both. Traffic patterns can be bursty in nature and contain
many-to-one, many-to-many, or one-to-many flows. Each flow may also
be small and latency sensitive or large and throughput sensitive
while containing a mix of UDP and TCP traffic. All of which can
coexist in a single cluster and flow through a single network device
all at the same time. Benchmarking of network devices have long used
RFC1242, RFC2432, RFC2544, RFC2889 and RFC3918. These benchmarks have
largely been focused around various latency attributes and max
throughput of the Device Under Test being benchmarked. These
standards are good at measuring theoretical max throughput,
forwarding rates and latency under testing conditions, but to not
represent real traffic patterns that may affect these networking
devices.
The following defines a set of definitions, metrics and terminologies
including congestion scenarios, switch buffer analysis and redefines
basic definitions in order to represent a wide mix of traffic
conditions.
Avramov & Rapp Expires April 20, 2015 [Page 3]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
1.1. Requirements Language
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in RFC 2119 [6].
1.2. Definition format
Term to be defined. (e.g., Latency)
Definition: The specific definition for the term.
Discussion: A brief discussion about the term, it's application and
any restrictions on measurement procedures.
Measurement Units: Methodology for the measure and units used to
report measurements of this term, if applicable.
2. Latency
2.1. Definition
Latency is a the amount of time it takes a frame to transit the DUT.
The Latency interval can be assessed between different combinations
of events, irrespectively of the type of switching device (bit
forwarding aka cut-through or store forward type of device)
Traditionally the latency measurement definitions are:
FILO (First In Last Out) The time interval starting when the end of
the first bit of the input frame reaches the input port and ending
when the last bit of the output frame is seen on the output port
FIFO (First In First Out) The time interval starting when the end of
the first bit of the input frame reaches the input port and ending
when the start of the first bit of the output frame is seen on the
output port
LILO (Last In Last Out) The time interval starting when the last bit
of the input frame reaches the input port and the last bit of the
output frame is seen on the output port
LIFO (Last In First Out) The time interval starting when the last
bit of the input frame reaches the input port and ending when the
Avramov & Rapp Expires April 20, 2015 [Page 4]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
first bit of the output frame is seen on the output port.
Another possibility to summarize the four different definitions above
is to refer to the bit position as they normally occur: input to
output.
FILO is FL (First bit Last bit) FIFO is FF (First bit First
bit) LILO is LL (Last bit Last bit) LIFO is LF (Last bit First bit)
This definition explained in this section in context of data center
switching benchmarking is in lieu of the previous definition of
Latency defined in RFC 1242, section 3.8 and is quoted here:
For store and forward devices: The time interval starting when the
last bit of the input frame reaches the input port and ending when
the first bit of the output frame is seen on the output port.
For bit forwarding devices: The time interval starting when the end
of the first bit of the input frame reaches the input port and ending
when the start of the first bit of the output frame is seen on the
output port.
2.2 Discussion
FILO is the most important measuring definition. Any type of switches
MUST be measured with the FILO mechanism: FILO will include the
latency of the switch and the latency of the frame as well as the
serialization delay. It is a picture of the 'whole' latency going
through the DUT. For applications, which are latency sensitive and
can function with initial bytes of the frame, FIFO MAY be an
additional type of measuring to supplement FILO.
LIFO mechanism can be used with store forward type of switches but
not with cut-through type of switches, as it will provide negative
latency values for larger packet sizes. Therefore this mechanism MUST
NOT be used when comparing latencies of two different DUTs.
2.3 Measurement Units
The measuring methods to use for benchmarking purposes are as follow:
1) FILO MUST be used as a measuring method, as this will include the
latency of the packet; and today the application commonly need to
read the whole packet to process the information and take an action.
2) FIFO MAY be used for certain applications able to proceed data as
Avramov & Rapp Expires April 20, 2015 [Page 5]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
the first bits arrive (FPGA for example)
3) LIFO MUST not be used, because it subtracts the latency of the
packet; unlike all the other methods.
3 Jitter
3.1 Definition
The definition of Jitter is covered extensively in RFC 3393. This
definition is not meant to replace that definition, but it is meant
to provide guidance of use for data center network devices.
The use of Jitter is in according with the variation delay definition
from RFC 3393:
The second meaning has to do with the variation of a metric (e.g.,
delay) with respect to some reference metric (e.g., average delay or
minimum delay). This meaning is frequently used by computer
scientists and frequently (but not always) refers to variation in
delay.
Even with the reference to RFC 3393, there are many definitions of
"jitter" possible. The one selected for Data Center Benchmarking is
closest to RFC 3393.
3.2 Discussion
Jitter can be measured in different scenarios:-packet to packet delay
variation-delta between min and max packet delay variation for all
packets sent.
3.3 Measurement Units
The jitter MUST be measured when sending packets of the same size.
Jitter MUST be measured as packet to packet delay variation and delta
between min and max packet delay variation of all packets sent. A
histogram MAY be provided as a population of packets measured per
latency or latency buckets.
4 Physical Layer Calibration
4.1 Definition
The calibration of the physical layer consists of defining and
measuring the latency of the physical devices used to perform test on
Avramov & Rapp Expires April 20, 2015 [Page 6]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
the DUT.
It includes the list of all physical layer components used as listed
here after:
-type of device used to generate traffic / measure traffic
-type of line cards used on the traffic generator
-type of transceivers on traffic generator
-type of transceivers on DUT
-type of cables
-length of cables
-software name, and version of traffic generator and DUT
-list of enabled features on DUT MAY be provided and is recommended
[especially the control plane protocols such as LLDP, Spanning-Tree
etc.]. A comprehensive configuration file MAY be provided to this
effect.
4.2 Discussion
Physical layer calibration is part of the end to end latency, which
should be taken into acknowledgment while evaluating the DUT. Small
variations of the physical components of the test may impact the
latency being measure so they MUST be described when presenting
results.
4.3 Measurement Units
It is RECOMMENDED to use all cables of : the same type, the same
length, when possible using the same vendor. It is a MUST to document
the cables specifications on section [4.1s] along with the test
results. The test report MUST specify if the cable latency has been
removed from the test measures or not. The accuracy of the traffic
generator measure MUST be provided [this is usually a value in the
20ns range for current test equipment].
5 Line rate
5.1 Definition
Avramov & Rapp Expires April 20, 2015 [Page 7]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
The transmit timing, or maximum transmitted data rate is controlled
by the "transmit clock" in the DUT. The receive timing (maximum
ingress data rate) is derived from the transmit clock of the
connected interface.
The line rate or physical layer frame rate is the maximum capacity to
send frames of a specific size at the transmit clock frequency of the
DUT.
The term port capacity term defines the maximum speed capability for
the given port; for example 1GE, 10GE, 40GE, 100GE etc.
The frequency ("clock rate") of the transmit clock in any two
connected interfaces will never be precisely the same, therefore a
tolerance is needed, this will be expressed by Parts Per Million
(PPM) value. The IEEE standards allow a specific +/- variance in the
transmit clock rate, and Ethernet is designed to allow for small,
normal variations between the two clock rates. This results in a
tolerance of the line rate value when traffic is generated from a
testing equipment to a DUT.
5.2 Discussion
For a transmit clock source, most Ethernet switches use "clock
modules" (also called "oscillator modules") that are sealed,
internally temperature-compensated, and very accurate. The output
frequency of these modules is not adjustable because it is not
necessary. Many test sets, however, offer a software-controlled
adjustment of the transmit clock rate, which should be used to
compensate the test equipment to not send more than line rate of the
DUT.
To allow for the minor variations typically found in the clock rate
of commercially-available clock modules and other crystal-based
oscillators, Ethernet standards specify the maximum transmit clock
rate variation to be not more than +/- 100 PPM (parts per million)
from a calculated center frequency. Therefore a DUT must be able to
accept frames at a rate within +/- 100 PPM to comply with the
standards.
Very few clock circuits are precisely +/- 0.0 PPM because:
1.The Ethernet standards allow a maximum of +/- 100 PPM (parts per
million) variance over time. Therefore it is normal for the frequency
of the oscillator circuits to experience variation over time and over
a wide temperature range, among external factors.
Avramov & Rapp Expires April 20, 2015 [Page 8]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
2.The crystals or clock modules, usually have a specific +/- PPM
variance that is significantly better than +/- 100 PPM. Often times
this is +/- 30 PPM or better in order to be considered a
"certification instrument".
When testing an Ethernet switch throughput at "line rate", any
specific switch will have a clock rate variance. If a test set is
running +1 PPM faster than a switch under test, and a sustained line
rate test is performed, a gradual increase in latency and eventually
packet drops as buffers fill and overflow in the switch can be
observed. Depending on how much clock variance there is between the
two connected systems, the effect may be seen after the traffic
stream has been running for a few hundred microseconds, a few
milliseconds, or seconds. The same low latency and no-packet-loss can
be demonstrated by setting the test set link occupancy to slightly
less than 100 percent link occupancy. Typically 99 percent link
occupancy produces excellent low-latency and no packet loss. No
Ethernet switch or router will have a transmit clock rate of exactly
+/- 0.0 PPM. Very few (if any) test sets have a clock rate that is
precisely +/- 0.0 PPM.
Test set equipment manufacturers are well-aware of the standards, and
allows a software-controlled +/- 100 PPM "offset" (clock-rate
adjustment) to compensate for normal variations in the clock speed of
"devices under test". This offset adjustment allows engineers to
determine the approximate speed the connected device is operating,
and verify that it is within parameters allowed by standards.
5.3 Measurement Units
"Line Rate" CAN be measured in terms of "Frame Rate":
Frame Rate = Transmit-Clock-Frequency / (Frame-Length*8 + Minimum_Gap
+ Preamble + Start-Frame Delimiter)
Example for 1 GB Ethernet speed with 64-byte frames: Frame Rate =
1,000,000,000 /(64*8 + 96 + 56 + 8) Frame Rate = 1,000,000,000 / 672
Frame Rate = 1,488,095.2 frames per second.
Considering the allowance of +/- 100 PPM, a switch may "legally"
transmit traffic at a frame rate between 1,487,946.4 FPS and
1,488,244 FPS. Each 1 PPM variation in clock rate will translate to
a 1.488 frame-per-second frame rate increase or decrease.
In a production network, it is very unlikely to see precise line rate
over a very brief period. There is no observable difference between
Avramov & Rapp Expires April 20, 2015 [Page 9]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
dropping packets at 99% of line rate and 100% of line rate. -Line
rate CAN measured at 100% of line rate with a -100PPM adjustment. -
Line rate SHOULD be measured at 99,98% with 0 PPM adjustment.-The PPM
adjustment SHOULD only be used for a line rate type of measurement
6 Buffering
6.1 Buffer
6.1.1 Definition
Buffer Size: the term buffer size, represents the total amount of
frame buffering memory available on a DUT. This size is expressed in
Byte; KB (kilobytes), MB (megabytes) or GB (gigabyte). When the
buffer size is expressed it SHOULD be defined by a size metric
defined above. When the buffer size is expressed, an indication of
the frame MTU used for that measurement is also necessary as well as
the cos or dscp value set; as often times the buffers are carved by
quality of service implementation. (please refer to the buffer
efficiency section for further details).
Example: Buffer Size of DUT when sending 1518 bytes frames is 18 Mb.
Port Buffer Size: the port buffer size is the amount of buffer a
single ingress port, egress port or combination of ingress and egress
buffering location for a single port. The reason of mentioning the
three locations for the port buffer is, that the DUT buffering scheme
can be unknown or untested, and therefore the indication of where the
buffer is located helps understand the buffer architecture and
therefore the total buffer size. The Port Buffer Size is an
informational value that MAY be provided from the DUT vendor. It is
not a value that is tested by benchmarking. Benchmarking will be done
using the Maximum Port Buffer Size or Maximum Buffer Size
methodology.
Maximum Port Buffer Size: this is in most cases the same as the Port
Buffer Size. In certain switch architecture called SoC (switch on
chip), there is a concept of port buffer and shared buffer pool
available for all ports. Maximum Port Buffer, defines the scenario of
a SoC buffer, where this amount in B (byte), KB (kilobyte), MB
(megabyte) or GB (gigabyte) would represent the sum of the port
buffer along with the maximum value of shared buffer this given port
can take. The Maximum Port Buffer Size needs to be expressed along
with the frame MTU used for the measurement and the cos or dscp bit
value set for the test.
Example: a DUT has been measured to have 3KB of port buffer for 1518
Avramov & Rapp Expires April 20, 2015 [Page 10]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
frame size packets and a total of 4.7 MB of maximum port buffer for
1518 frame size packets and a cos of 0.
Maximum DUT Buffer Size: this is the total size of Buffer a DUT can
be measured to have. It is most likely different than the Maximum
Port Buffer Size. It CAN also be different from the sum of Maximum
Port Buffer Size. The Maximum Buffer Size needs to be expressed along
with the frame MTU used for the measurement and along with the cos or
dscp value set during the test.
Example: a DUT has been measured to have 3KB of port buffer for 1518
frame size packets and a total of 4.7 MB of maximum port buffer for
1518 frame size packets. The DUT has a Maximum Buffer Size of 18 MB
at 1500 bytes and a cos of 0.
Burst: The burst is a fixed number of packets sent over a percentage
of linerate of a defined port speed. The amount of frames sent are
evenly distributed across the interval T. A constant C, can be
defined to provide the average time between two consecutive packets
evenly spaced.
Microburst: it is a burst. A microburst is when packet drops occur
when there is not sustained or noticeable congestion upon a link or
device. A characterization of microburst is when the Burst is not
evenly distributed over T, and is less than the constant C [C=
average time between two consecutive packets evenly spaced out].
Intensity of Microburst: this is a percentage, representing the level
of microburst between 1 and 100%. The higher the number the higher
the microburst is. I=[1-[ (TP2-Tp1)+(Tp3-Tp2)+....(TpN-Tp(n-1) ] /
Sum(packets)]]*100
6.1.3 Discussion
When measuring buffering on a DUT, it is important to understand what
the behavior is for each port, and also for all ports as this will
provide an evidence of the total amount of buffering available on the
switch. The terms of buffer efficiency here helps one understand what
is the optimum packet size for the buffer to be used, or what is the
real volume of buffer available for a specific packet size. This
section does not discuss how to conduct the test methodology, it
rather explains the buffer definitions and what metrics should be
provided for a comprehensive data center device buffering
benchmarking.
6.1.3 Measurement Units
When Buffer is measured:-the buffer size MUST be measured-the port
Avramov & Rapp Expires April 20, 2015 [Page 11]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
buffer size MAY be provided for each port-the maximum port buffer
size MUST be measured-the maximum DUT buffer size MUST be measured-
the intensity of microburst MAY be mentioned when a microburst test
is performed-the cos or dscp value set during the test SHOULD be
provided
6.2 Incast
6.2.1 Definition
The term Incast, very commonly utilized in the data center, refers to
the traffic pattern of many-to-one or many-to-many conversations.
Typically in the data center it would refer to many different ingress
server ports(many), sending traffic to a common uplink (one), or
multiple uplinks (many). This pattern is generalized for any network
as many incoming ports sending traffic to one or few uplinks. It can
also be found in many-to-many traffic patterns.
Synchronous arrival time: When two, or more, frames of respective
sizes L1 and L2 arrive at their respective one or multiple ingress
ports, and there is an overlap of the arrival time for any of the
bits on the DUT, then the frames L1 and L2 have a synchronous arrival
times. This is called incast.
Asynchronous arrival time: Any condition not defined by synchronous.
Percentage of synchronization: this defines the level of overlap
[amount of bits] between the frames L1,L2..Ln.
Example: two 64 bytes frames, of length L1 and L2, arrive to ingress
port 1 and port 2 of the DUT. There is an overlap of 6.4 bytes
between the two where L1 and L2 were at the same time on the
respective ingress ports. Therefore the percentage of synchronization
is 10%.
Stateful type traffic defines packets exchanged with a stateful
protocol such as for example TCP.
Stateless type traffic defines packets exchanged with a stateless
protocol such as for example UDP.
6.2.2 Discussion
In this scenario, buffers are solicited on the DUT. In a ingress
buffering mechanism, the ingress port buffers would be solicited
along with Virtual Output Queues, when available; whereas in an
Avramov & Rapp Expires April 20, 2015 [Page 12]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
egress buffer mechanism, the egress buffer of the one outgoing port
would be used.
In either cases, regardless of where the buffer memory is located on
the switch architecture; the Incast creates buffer utilization.
When one or more frames having synchronous arrival times at the DUT
they are considered forming an incast.
6.2.3 Measurement Units
It is a MUST to measure the number of ingress and egress ports. It is
a MUST to have a non null percentage of synchronization, which MUST
be specified.
7 Application Throughput: Data Center Goodput
7.1. Definition
In Data Center Networking, a balanced network is a function of
maximal throughput 'and' minimal loss at any given time. This is
defined by the Goodput. Goodput is the application-level throughput.
It is measured in bytes / second. Goodput is the measurement of the
actual payload of the packet being sent.
7.2. Discussion
In data center benchmarking, the goodput is a value that SHOULD be
measured. It provides a realistic idea of the usage of the available
bandwidth. A goal in data center environments is to maximize the
goodput while minimizing the loss.
7.3. Measurement Units
When S is the total bytes received from all senders [not inclusive of
packet headers or TCP headers - it's the payload] and Ft is the
Finishing Time of the last sender; the Goodput G is then measured by
the following formula: G= S / Ft bytes per second
Example: a TCP file transfer over HTTP protocol on a 10Gb/s media.
The file cannot be transferred over Ethernet as a single continuous
stream. It must be broken down into individual frames of 1500 bytes
when the standard MTU [Maximum Transmission Unit] is used. Each
packet requires 20 bytes of IP header information and 20 bytes of TCP
Avramov & Rapp Expires April 20, 2015 [Page 13]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
header information, therefore 1460 byte are available per packet for
the file transfer. Linux based systems are further limited to 1448
bytes as they also carry a 12 byte timestamp. Finally, the date is
transmitted in this example over Ethernet which adds a 26 byte
overhead per packet.
G= 1460/1526 x 10 Gbit/s which is 9.567 Gbit/s or 1.196 Gigabytes per
second.
Please note: this example does not take into consideration additional
Ethernet overhead, such as the interframe gap (a minimum of 96 bit
times), nor collisions (which have a variable impact, depending on
the network load).
When conducting Goodput measurements please document in addition to
the 4.1 section:
-the TCP Stack used
-OS Versions
-NIC firmware version and model
For example, Windows TCP stacks and different Linux versions can
influence TCP based tests results.
8. References
3.1. Normative References
[1] Bradner, S. "Benchmarking Terminology for Network
Interconnection Devices", RFC 1242, July 1991.
[2] Bradner, S. and J. McQuaid, "Benchmarking Methodology for
Network Interconnect Devices", RFC 2544, March 1999.
3.2. Informative References
[3] Mandeville R. and Perser J., "Benchmarking Methodology for LAN
Switching Devices", RFC 2889, August 2000.
[4] Stopp D. and Hickman B., "Methodology for IP Multicast
Benchmarking", BCP 26, RFC 3918, October 2004.
3.3. URL References
[5] Yanpei Chen, Rean Griffith, Junda Liu, Randy H. Katz, Anthony D.
Avramov & Rapp Expires April 20, 2015 [Page 14]
Internet-Draft Data Center Benchmarking Definitions October 17, 2014
Joseph, "Understanding TCP Incast Throughput Collapse in
Datacenter Networks",
http://www.eecs.berkeley.edu/~ychen2/professional/TCPIncastWREN2009.pdf".
3.4. Acknowledgments
The authors would like to thank Ian Cox and Tim Stevenson for
their reviews and feedback.
Authors' Addresses
Lucien Avramov
Cisco Systems
170 West Tasman drive
San Jose, CA 95134
United States
Phone: +1 408 526 7686
Email: lavramov@cisco.com
Jacob Rapp
Hewlett-Packard Company
3000 Hanover Street
Palo Alto, CA 94304
United States
Phone: +1 650 857 3367
Email: jacob.h.rapp@hp.com
Avramov & Rapp Expires April 20, 2015 [Page 15]