Internet DRAFT - draft-dunbar-trill-directory-assisted-edge
draft-dunbar-trill-directory-assisted-edge
TRILL working group L. Dunbar
Internet Draft D. Eastlake
Intended status: Standard Track Huawei
Expires: Sept 2012 Radia Perlman
Intel
I. Gashinsky
Yahoo
March 11, 2012
Directory Assisted RBridge Edge
draft-dunbar-trill-directory-assisted-edge-05.txt
Status of this Memo
This Internet-Draft is submitted in full conformance with the
provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF). Note that other groups may also distribute
working documents as Internet-Drafts. The list of current Internet-
Drafts is at http://datatracker.ietf.org/drafts/current/.
Internet-Drafts are draft documents valid for a maximum of six
months and may be updated, replaced, or obsoleted by other documents
at any time. It is inappropriate to use Internet-Drafts as
reference material or to cite them other than as "work in progress."
This Internet-Draft will expire on September 11, 2012.
Copyright Notice
Copyright (c) 2012 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with
respect to this document. Code Components extracted from this
document must include Simplified BSD License text as described in
Section 4.e of the Trust Legal Provisions and are provided without
warranty as described in the Simplified BSD License.
Abstract
Dunbar Expires September 11, 2012 [Page 1]
Internet-Draft Directory Assisted RBridge edge March 2011
RBridge edge nodes currently learn the mapping between MAC addresses
and their corresponding RBridge edge nodes by observing the data
packets traversed through. When ingress RBridge receives a data
packet with its destination address (MAC&VLAN) unknown, the data
packet is flooded across RBridge domain. When there are more than
one RBridge ports connected to one bridged LAN, only one of them can
be designated as AF port for forwarding/receiving traffic for each
LAN, the rest have to be blocked for that LAN.
This draft describes the framework of using directory assisted
RBridge edge to improve TRILL network scalability in data center
environment.
Conventions used in this document
The term ''Subnet'' and ''VLAN'' are used interchangeably in this
document because it is common to map one subnet to one VLAN. The
term ''TRILL'' and ''RBridge'' are used interchangeably in this
document.
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in RFC-2119 0.
Table of Contents
1. Introduction ................................................ 3
2. Terminology ................................................. 3
3. Impact on RBridge domain of massive number of hosts in Data
Center ......................................................... 4
3.1. Issues of Flooding Based Learning in Data Centers ........ 4
3.2. Some Examples .......................................... 5
4. Benefits of Directory Assisted RBridge Edge in DC Environment . 7
5. Generic operation of Directory Assistance.................... 8
5.1. Information in Directory Servers for TRILL.............. 8
5.2. Push Model ............................................. 8
5.3. Pull model: ........................................... 10
6. Conclusion and Recommendation............................... 11
7. Manageability Considerations................................ 11
8. Security Considerations..................................... 11
9. IANA Considerations ........................................ 11
10. Acknowledgments ........................................... 11
11. References ................................................ 12
Authors' Addresses ............................................ 12
Intellectual Property Statement................................ 13
Disclaimer of Validity ........................................ 13
Dunbar Expires Sept11, 2012 [Page 2]
Internet-Draft Directory Assisted RBridge edge March 2011
1. Introduction
Data center networks are different from campus networks in several
ways, in particular:
1. Data centers, especially Internet or multi-tenant data centers,
tend to have large number of hosts with a wide variety of
applications.
2. Topology is based on racks and rows.
Hosts assignment to Servers, Racks, and Rows is orchestrated
by Server/VM Management system, not at random.
3. Rapid workload shifting in data centers can accelerate the
frequency of one physical server being re-loaded with different
applications. Sometimes, applications re-loaded to one physical
server at different time can belong to different subnets.
4. With server virtualization, there is an ever-increasing trend to
dynamically create or delete VMs when demand for resource changes,
to move VMs from overloaded servers, or to aggregate VMs onto
fewer servers when demand is light.
Both 3) and 4) above can lead to hosts in one subnet being placed
under different locations (racks or rows) or one rack having hosts
belonging to different subnets.
This draft describes why and how Data Center TRILL networks can be
optimized by utilizing a directory assisted approach.
2. Terminology
AF Appointed Forwarder RBridge port
Bridge: IEEE 802.1Q compliant device. In this draft, Bridge is used
interchangeably with Layer 2 switch.
DA: Destination Address
DC: Data Center
EoR: End of Row switches in data center. Also known as
Aggregation switches in some data centers
FDB: Filtering Database for Bridge or Layer 2 switch
Dunbar Expires Sept11, 2012 [Page 3]
Internet-Draft Directory Assisted RBridge edge March 2011
Host: Application running on a physical server or a virtual
machine. A host usually has at least one IP address and at
least one MAC address.
SA: Source Address
STP: Spanning Tree Protocol
RSTP: Rapid Spanning Tree Protocol
ToR: Top of Rack Switch in data center. It is also known as
access switches in some data centers.
VM: Virtual Machines
3. Impact on RBridge domain of massive number of hosts in Data Center
3.1. Issues of Flooding Based Learning in Data Centers
It is common for Data Center networks to have multiple tiers of
switches, e.g. one or two Access Switches for each server rack
(ToR), aggregation switches for some rows (or EoR switches), and
some core switches to interconnect the aggregation switches. Many
aggregation switches deployed in data centers are high port density
switches. It is not uncommon to see aggregation switches
interconnecting hundreds of ToR switches.
+-------+ +------+
+/------+ | +/-----+ |
| Aggr11| + ----- |AggrN1| + EoR Switches
+---+---+/ +------+/
/ \ / \
/ \ / \
+---+ +---+ +---+ +---+
|T11|... |T1x| |T21| ? |T2y| ToR switches
+---+ +---+ +---+ +---+
| | | |
+-|-+ +-|-+ +-|-+ +-|-+
| |... | | | | ? | |
+---+ +---+ +---+ +---+ Server racks
| |... | | | | ? | |
+---+ +---+ +---+ +---+
| |... | | | | ? | |
+---+ +---+ +---+ +---+
Figure 1: Typical Data Center Network Design
Dunbar Expires Sept11, 2012 [Page 4]
Internet-Draft Directory Assisted RBridge edge March 2011
When TRILL is deployed in a data center with large number of hosts,
with the possibility of hosts in one subnet/VLAN being placed under
multiple edge RBridges and each edge RBridge having hosts from
different subnets/VLANs, the following problems will occur:
Unnecessary filling of slots in MAC table of edge RBridges, due
to edge RBridge receiving broadcast/multicast traffic (e.g.
ARP/ND, cluster multicast, etc.) from hosts under other edge
RBridges that are not actually communicating with any hosts
attached to the RBridge.
Some edge RBridge ports being blocked for user traffic when
there are more than one RBridge ports connected to one bridged
LAN. When there are multiple RBridge ports connected to a
bridged LAN, only one, i.e. the AF port, can forward/receive
traffic for that bridged LAN (i.e. VLAN), the rest have to be
blocked for forwarding/receiving traffic for that VLAN. When a
rack has dual uplinks to two different ToR switches ( RBridge
Edges), which is very common in data center environment, some
links can't be fully utilized.
Packets being flooded across RBridge domain when their DAs are
not in ingress RBridge's cache.
In an environment where VMs migrates, there is higher chance of
cached entries becoming invalid, causing traffic to be black
holed or re-flooded by the egress RBridge. If VMs send out
gratuitous ARP/ND or IEEE802.1Qbg's VDP upon arriving at new
locations, the ingress nodes might not have the MAC entries for
the newly arrived VMs, causing more unknown flooding.
3.2. Some Examples
Consider a data center with 1600 server racks. Each server rack has
at least one ToR switch. The ToR switches are further divided to 8
groups, with each group being connected by a set of aggregation
switches. There could be 4 to 8 aggregation switches in each set to
achieve load sharing for traffic to/from server racks. If TRILL is
to be deployed in this data center environment, let's consider
following two scenarios for the TRILL domain boundary:
Scenario #1: TRILL domain boundary starts at ToR switches:
Dunbar Expires Sept11, 2012 [Page 5]
Internet-Draft Directory Assisted RBridge edge March 2011
If each server rack has one uplink to one ToR, there are 1600
edge RBridges. If each rack has dual uplinks to two ToR
switches, then there will be 3200 edge RBridges
In this scenario, the RBridge domain will have more than 1600
(or 3200) + 8*4 (or 8*8) nodes, which is quite a large IS-IS
domain. Even though a mesh IS-IS domain can scale up to
thousands of nodes, it is very challenging for aggregation
switches to handle IS-IS link state advertisement among
hundreds of parallel ports.
Scenario #2: TRILL domain boundary starts at the aggregation
switches:
With the same assumption as before, the number of nodes in
RBridge domain will be less than 100, and aggregation switches
don't have to handle IS-IS link state advisements among
hundreds of ports.
But in this scenario, aggregation switches' downstream
ports/links to ToR switches form the bridged LAN with links
from ToR switches to servers. With aggregation switches being
the RBridge edge nodes, multiple RBridge edge ports could be
connected to one bridged LAN. To avoid potential loops TRILL
requires only one of multiple RBridge edge ports connected to
one VLAN being designated as Appointed Forwarder (AF port) for
forwarding native traffic across RBridge domain for that VLAN.
That means other ports/links are blocked for native frames in
that VLAN.
There is also possibility of loops on the bridged LAN attached
to RBridge edge ports unless STP/RSTP is running. Running
traditional Layer 2 STP/RSTP on the bridged LAN in this
environment may be overkill because the topology among the ToR
switches and aggregation switches is very simple.
In addition, the number of MAC&VLAN<->RBridgeEdge Mapping
entries to be learned and managed by RBridge edge node can be
very large. In the example above, each edge RBridge has 200
edge ports facing the ToR switches. If each ToR has 40
downstream ports facing servers and each server has 10 VMs,
there could be 200*40*10 = 80000 hosts attached. If all those
hosts belong to 1600 VLANs (i.e. 50 per VLAN) and each VLAN has
200 hosts, then under the worst case scenario, the total number
Dunbar Expires Sept11, 2012 [Page 6]
Internet-Draft Directory Assisted RBridge edge March 2011
of MAC&VLAN entries to be learned by the RBridge edge can be
1600*200=320000, which is very large.
4. Benefits of Directory Assisted RBridge Edge in DC Environment
In data center environment, applications placement to servers,
racks, and rows is orchestrated by Server (or VM) Management
System(s). I.e. there is a database or multiple ones (distributed
model) which have the knowledge of where each host is located. If
that host location information can be fed to RBridge edge nodes, in
some form of Directory Service, then RBridge edge nodes won't need
to flood data frames with unknown DA across RBridge domain.
Avoiding unknown DA flooding to RBridge domain is especially
valuable in data center environment because there is higher chance
of an RBridge edge receiving packets with unknown DA and
broadcast/multicast messages due to VM migration and servers being
loaded with different applications. When a VM is moved to a new
location or a server is loaded with a new application with different
IP/MAC addresses, it is more likely that the DA of data packets sent
out from those hosts are unknown to their attached RBridge edges.
In addition, gratuitous ARP (IPv4) or Unsolicited Neighbor
Advertisement (IPv6) sent out from those newly migrated or activated
hosts have to be flooded to other RBridge edges which have hosts in
the same subnets.
The benefits of using directory assistance include:
Avoid flooding unknown DA across RBridge domain. The Directory
enforced MAC&VLAN <-> RBridgeEdge mapping table can determine
if a data packet needs to be forwarded across RBridge domain.
When multiple RBridge edge ports are connected via bridged LAN
to hosts (servers/VMs), a directory assisted RBridge edge won't
need to flood unknown DA data frames to all ports of the
RBridge edge. Under this circumstance, there is no chance for
those data frames looping among multiple ports of RBridge edge.
Therefore, it is no longer necessary to designate one Appointed
Forwarder among all the RBridge Edge ports connected to a
bridge LAN, which means that all RBridge ports can
forward/receive traffic.
Reduce flooding decapsulated Ethernet frames with unknown MAC-
DA to a bridged LAN connected to RBridge edge ports.
Dunbar Expires Sept11, 2012 [Page 7]
Internet-Draft Directory Assisted RBridge edge March 2011
When an RBridge receives a TRILL frame whose destination
Nickname matches with its own, the normal procedure is for the
RBridge to decapsulate the TRILL header and forward the
decapsulated Ethernet frame to its directly attached bridged
LAN. If the destination MAC is unknown, the decapsulated
Ethernet frame is flooded in the LAN. With directory
assistance, the RBridge edge can determine if DA in a frame
matches with any hosts attached via the bridged LAN. Therefore,
frames can be discarded if their DAs do not match.
Reduce the amount of MAC&VLAN <-> RBridgeEdge mapping
maintained by RBridge edge. There is no need for an RBridge
edge to keep the MAC entries for hosts which don't communicate
with hosts attached to the RBridge edge.
5. Generic operation of Directory Assistance
5.1. Information in Directory Servers for TRILL
To achieve the benefits of directory service for TRILL, the
corresponding directory server will need minimum following
attributes:
[IP, MAC, attached RBridge nickname, {list of interested RBridges}]
The {list of interested RBridges} would get populated when an
RBridge queries for information, or pushed down from management
systems. The list is used to notify those RBridges if VMs to
RBridge's connectivity changes due to VMs migration or link
failures.
There can be two different models for RBridge edge node to be
assisted by Directory Service: Push Model and Pull Model.
5.2. Push Model
Under this model, Directory Server(s) push down the MAC&VLAN <->
RBridgeEdge mapping for all the hosts which might communicate with
hosts attached to an RBridge edge node. With this environment, it is
recommended that RBridge edge simply drop a data packet (instead of
flooding to RBridge domain) if the packet's destination address
can't be found in the MAC&VLAN<->RBridgeEdge mapping table.
Dunbar Expires Sept11, 2012 [Page 8]
Internet-Draft Directory Assisted RBridge edge March 2011
It may not be necessary for every RBridge edge to get the entire
mapping table for all the hosts in a data center. There are many
ways to narrow the full set down to a smaller set of remote hosts
which communicate with hosts attached to an RBridge edge. A simple
approach of only pushing down the mapping for the VLANs which have
active hosts under an RBridge edge can reduce the number of mapping
entries pushed down.
However, it is inevitable that RBridge edge's MAC&VLAN<->RBridgeEdge
mapping table will have more entries than they really need under the
Push Model. When hosts attached to one RBridge Edge rarely
communicate with hosts attached to different RBridge edges even
though they are on the same VLAN, the normal process of RBridge
edge's unknown DA flooding, learning and cache aging would have
removed those MAC&VLAN entries from the RBridge's cache. But it can
be difficult for Directory Servers to predict the communication
patterns among hosts within one VLAN. Therefore, it is likely that
the Directory Servers will push down all the MAC&VLAN entries if
there are hosts in the VLAN being attached to the RBridge Edge. This
is a major disadvantage of push down model.
In push down model, it is necessary to have a message for RBridge
node to request directory server(s) to start pushing down the
mapping entries. This message should at least include the number
VLANs enabled on the RBridge, so that directory server doesn't need
to push down the entire mapping entries for all the hosts in the
data center. RBridge node can use this message to get mapping
entries when it is initialized or restarted.
The detailed message format and hand-shake mechanism between RBridge
and Directory Server(s) will be described in a separate draft
because this draft only focuses on the framework of directory
assisted Edge.
When directory pushes down the entire mapping to an edge RBridge for
the very first time, there usually are many entries. To minimize the
number of entries pushed down, summarization should be considered,
e.g. with one edge RBridge Nickname being associated with all
attached hosts' MAC addresses and VLANs as shown below:
Dunbar Expires Sept11, 2012 [Page 9]
Internet-Draft Directory Assisted RBridge edge March 2011
+------------+-------+--------------------------------+
| Nickname1 |VID-1 | MAC1, MAC2, ,MACn |
| |------ +--------------------------------+
| |VID-2 | MAC1, MAC2, ,MACn |
| |------ +--------------------------------+
| |... | MAC1, MAC2, ,MACn |
+------------+------ +--------------------------------+
| Nickname2 |VID-1 | MAC1, MAC2, ,MACn |
| |------ +--------------------------------+
| |VID-2 | MAC1, MAC2, ,MACn |
| |------ +--------------------------------+
| |... | MAC1, MAC2, ,MACn |
+------------+------ +--------------------------------+
| ------- |------ +--------------------------------+
| |... | MAC1, MAC2, ,MACn |
+------------+------ +--------------------------------+
Table 1: Summarized table pushed down from directory
Whenever there is any change in MAC&VLAN <-> RBridgeEdge mapping,
which can be triggered by hosts being added, moved, or de-
commissioned, an incremental update can be sent to the RBridge edges
which are impacted by the change. Therefore, something like sequence
number has to be maintained by directory servers and RBridges.
Detailed mechanisms will be described in a separate draft.
5.3. Pull model:
Under this model, ''RBridge'' pulls the MAC&VLAN<->RBridgeEdge mapping
entry from the directory server when needed. There are several
options to trigger the pulling process. For example, the RBridge
edge node can send a pulling request whenever it receives an unknown
DA, or RBridge edge node can simply intercept all ARP/ND requests
and forward them to the Directory Server(s) that has the information
on where each host is located. RBridge ingress node can cache the
mapping pulled down from the directory.
One advantage of the Pull Model is that RBridge edge can age out
MAC&VLAN entries if they haven't been used for a certain period of
time. Therefore, each RBridge edge will only keep the entries which
are frequently used, i.e. mapping table size can be smaller. RBridge
edge would query the Directory Server(s) for unknown DAs in data
frames or ARP/ND and cache the response. When hosts attached to one
RBridge Edge rarely communicate with hosts attached to different
RBridge edges even though they are on the same VLAN, the
corresponding MAC&VLAN entries would be aged out from the RBridge's
cache.
Dunbar Expires Sept11, 2012 [Page 10]
Internet-Draft Directory Assisted RBridge edge March 2011
Some people are concerned of the performance with RBridge waiting
for response from Directory Servers upon receiving a data frame with
unknown DA. Actually this waiting practice is a common router
behavior. Most deployed routers today do hold the packets and send
an ARP/ND to the target upon receiving a packet with DA not in its
IP-MAC cache. When ARP/ND replies are received, the router will send
the data frame to the target. This practice is to minimize flooding
when targets don't exist in the subnet.
When the target doesn't exist in the subnet, routers generally re-
send ARP/ND request a few more times before dropping the packets.
Therefore, the holding time by routers to wait for ARP/ND response
can be longer than the time taken by the Pull Model to get IP-MAC
mapping from directory if target doesn't exist in the subnet.
A separate draft will describe the detailed messages and mechanism
for RBridge edge to pull information from directory server(s).
6. Conclusion and Recommendation
The traditional RBridge learning approach of observing data plane
can no longer keep pace with the ever growing number of hosts in
Data center.
Therefore, we suggest TRILL consider directory assisted
approach(es). This draft only describes the basic framework of using
directory assisted approach for RBridge edge nodes. More complete
mechanisms will be described in separate drafts.
7. Manageability Considerations
TBD.
8. Security Considerations
TBD.
9. IANA Considerations
TBD
10. Acknowledgments
This document was prepared using 2-Word-v2.0.template.dot.
Dunbar Expires Sept11, 2012 [Page 11]
Internet-Draft Directory Assisted RBridge edge March 2011
11. References
[RBridges] Perlman, et, al ''RBridge: Base Protocol Specification'',
<draft-ietf-trill-rbridge-protocol-16.txt>, March, 2010
[RBridges-AF] Perlman, et, al ''RBridges: Appointed Forwarders'',
<draft-ietf-trill-rbridge-af-02.txt>, April 2011
[ARMD-Problem] Dunbar, et,al, ''Address Resolution for Large Data
Center Problem Statement'', Oct 2010.
[ARP reduction] Shah, et. al., "ARP Broadcast Reduction for Large Data
Centers", Oct 2010
Authors' Addresses
Linda Dunbar
Huawei Technologies
5430 Legacy Drive, Suite #175
Plano, TX 75024, USA
Phone: (469) 277 5840
Email: ldunbar@huawei.com
Donald Eastlake
Huawei Technologies
155 Beaver Street
Milford, MA 01757 USA
Phone: 1-508-333-2270
Email: d3e3e3@gmail.com
Dunbar Expires Sept11, 2012 [Page 12]
Internet-Draft Directory Assisted RBridge edge March 2011
Radia Perlman
Intel Labs
2200 Mission College Blvd.
Santa Clara, CA 95054-1549 USA
Phone: +1-408-765-8080
Email: Radia@alum.mit.edu
Igor Gashinsky
Yahoo
45 West 18th Street 6th floor
New York, NY 10011
Email: igor@yahoo-inc.com
Intellectual Property Statement
The IETF Trust takes no position regarding the validity or scope of
any Intellectual Property Rights or other rights that might be
claimed to pertain to the implementation or use of the technology
described in any IETF Document or the extent to which any license
under such rights might or might not be available; nor does it
represent that it has made any independent effort to identify any
such rights.
Copies of Intellectual Property disclosures made to the IETF
Secretariat and any assurances of licenses to be made available, or
the result of an attempt made to obtain a general license or
permission for the use of such proprietary rights by implementers or
users of this specification can be obtained from the IETF on-line
IPR repository at http://www.ietf.org/ipr
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights that may cover technology that may be required to implement
any standard or specification contained in an IETF Document. Please
address the information to the IETF at ietf-ipr@ietf.org.
Disclaimer of Validity
All IETF Documents and the information contained therein are
provided on an "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION
HE/SHE REPRESENTS OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY,
THE IETF TRUST AND THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY
WARRANTY THAT THE USE OF THE INFORMATION THEREIN WILL NOT INFRINGE
Dunbar Expires Sept11, 2012 [Page 13]
Internet-Draft Directory Assisted RBridge edge March 2011
ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE.