Abstract
Constrained devices are nodes with limited processing power, storage
space and transmission capacities. These devices in many cases do
not provide user interfaces and are often intended to interact
without human intervention.
This document includes a collection of representative use cases for
authentication and authorization in constrained environments. These
use cases aim at identifying authorization problems that arise during
the lifecycle of a constrained device and are intended to provide a
guideline for developing a comprehensive authentication and
authorization solution for this class of scenarios.
Where specific details are relevant, it is assumed that the devices
use the Constrained Application Protocol (CoAP) as communication
protocol, however most conclusions apply generally.
Status of This Memo
This Internet-Draft is submitted in full conformance with the
provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF). Note that other groups may also distribute
working documents as Internet-Drafts. The list of current Internet-
Drafts is at http://datatracker.ietf.org/drafts/current/.
Seitz, et al. Expires April 25, 2016 [Page 1]
Internet-Draft ACE Use Cases October 2015
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
This Internet-Draft will expire on April 25, 2016.
Copyright Notice
Copyright (c) 2015 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1. Terminology . . . . . . . . . . . . . . . . . . . . . . . 4
2. Use Cases . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1. Container monitoring . . . . . . . . . . . . . . . . . . 4
2.1.1. Bananas for Munich . . . . . . . . . . . . . . . . . 5
2.1.2. Authorization Problems Summary . . . . . . . . . . . 6
2.2. Home Automation . . . . . . . . . . . . . . . . . . . . . 7
2.2.1. Controlling the Smart Home Infrastructure . . . . . . 7
2.2.2. Seamless Authorization . . . . . . . . . . . . . . . 7
2.2.3. Remotely letting in a visitor . . . . . . . . . . . . 8
2.2.4. Selling the house . . . . . . . . . . . . . . . . . . 8
2.2.5. Authorization Problems Summary . . . . . . . . . . . 8
2.3. Personal Health Monitoring . . . . . . . . . . . . . . . 9
2.3.1. John and the heart rate monitor . . . . . . . . . . . 10
2.3.2. Authorization Problems Summary . . . . . . . . . . . 11
2.4. Building Automation . . . . . . . . . . . . . . . . . . . 12
2.4.1. Device Lifecycle . . . . . . . . . . . . . . . . . . 12
2.4.2. Public Safety . . . . . . . . . . . . . . . . . . . . 16
2.4.3. Authorization Problems Summary . . . . . . . . . . . 16
2.5. Smart Metering . . . . . . . . . . . . . . . . . . . . . 18
2.5.1. Drive-by metering . . . . . . . . . . . . . . . . . . 18
2.5.2. Meshed Topology . . . . . . . . . . . . . . . . . . . 19
2.5.3. Advanced Metering Infrastructure . . . . . . . . . . 19
2.5.4. Authorization Problems Summary . . . . . . . . . . . 19
Seitz, et al. Expires April 25, 2016 [Page 2]
Internet-Draft ACE Use Cases October 2015
2.6. Sports and Entertainment . . . . . . . . . . . . . . . . 20
2.6.1. Dynamically Connecting Smart Sports Equipment . . . . 21
2.6.2. Authorization Problems Summary . . . . . . . . . . . 21
2.7. Industrial Control Systems . . . . . . . . . . . . . . . 22
2.7.1. Oil Platform Control . . . . . . . . . . . . . . . . 22
2.7.2. Authorization Problems Summary . . . . . . . . . . . 23
3. Security Considerations . . . . . . . . . . . . . . . . . . . 23
3.1. Attacks . . . . . . . . . . . . . . . . . . . . . . . . . 24
3.2. Configuration of Access Permissions . . . . . . . . . . . 25
3.3. Authorization Considerations . . . . . . . . . . . . . . 25
3.4. Proxies . . . . . . . . . . . . . . . . . . . . . . . . . 26
4. Privacy Considerations . . . . . . . . . . . . . . . . . . . 27
5. Acknowledgments . . . . . . . . . . . . . . . . . . . . . . . 27
6. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 27
7. Informative References . . . . . . . . . . . . . . . . . . . 27
Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . 28
1. Introduction
Constrained devices [RFC7228] are nodes with limited processing
power, storage space and transmission capacities. These devices are
often battery-powered and in many cases do not provide user
interfaces.
Constrained devices benefit from being interconnected using Internet
protocols. However, deploying common security protocols can
sometimes be difficult because of device or network limitations.
Regardless, adequate security mechanisms are required to protect
these constrained devices, which are expected to be integrated in all
aspects of everyday life, from attackers wishing to gain control over
the device's data or functions.
This document comprises a collection of representative use cases for
the application of authentication and authorization in constrained
environments. These use cases aim at identifying authorization
problems that arise during the lifecycle of a constrained device.
Note that this document does not aim at collecting all possible use
cases.
We assume that the communication between the devices is based on the
Representational State Transfer (REST) architectural style, i.e. a
device acts as a server that offers resources such as sensor data and
actuators. The resources can be accessed by clients, sometimes
without human intervention (M2M). In some situations the
communication will happen through intermediaries (e.g. gateways,
proxies).
Seitz, et al. Expires April 25, 2016 [Page 3]
Internet-Draft ACE Use Cases October 2015
Where specific detail is necessary it is assumed that the devices
communicate using CoAP [RFC7252], although most conclusions are
generic.
1.1. Terminology
Readers are required to be familiar with the terms defined in
[RFC7228].
2. Use Cases
This section includes the use cases; each use case first presents a
general description of the application environment, than one or more
specific use cases, and finally a summary of the authorization-
related problems to be solved. The document aims at listing the
relevant authorization problems and not to provide an exhaustive
list. It might not be possible to address all of the listed problems
with a single solution; There might be conflicting goals within or
among some requirements.
There are various reasons for assigning a function (client or server)
to a device, e.g. which device initiates the conversation, how do
devices find each other, etc. The definition of the function of a
device in a certain use case is not in scope of this document.
Readers should be aware that there might be reasons for each setting
and that endpoints might even have different functions at different
times.
2.1. Container monitoring
The ability of sensors to communicate environmental data wirelessly
opens up new application areas. Sensor systems make it possible to
continuously track and transmit characteristics such as temperature,
humidity and gas content while goods are transported and stored.
Sensors in this scenario have to be associated to the appropriate
pallet of the respective container. Sensors as well as the goods
belong to specific customers.
While in transit goods often pass stops where they are transloaded to
other means of transportation, e.g. from ship transport to road
transport.
Perishable goods need to be stored at constant temperature and with
proper ventilation. Real-time information on the state of the goods
is needed by both the transporter and the vendor. Transporters want
to prioritize good that will expire soon. Vendors want to react when
goods are spoiled to continue to fulfill delivery obligations.
Seitz, et al. Expires April 25, 2016 [Page 4]
Internet-Draft ACE Use Cases October 2015
The Intelligent Container (http://www.intelligentcontainer.com) is an
example project that explores solutions to continuously monitor
perishable goods.
2.1.1. Bananas for Munich
A fruit vendor grows bananas in Costa Rica for the German market. It
instructs a transport company to deliver the goods via ship to
Rotterdam where they are picked up by trucks and transported to a
ripening facility. A Munich supermarket chain buys ripened bananas
from the fruit vendor and transports them from the ripening facility
to the individual markets with their own company trucks.
The fruit vendor's quality management wants to assure the quality of
their products and thus equips the banana boxes with sensors. The
state of the goods is monitored consistently during shipment and
ripening and abnormal sensor values are recorded (U1.2).
Additionally, the sensor values are used to control the climate
within the cargo containers (U1.1, U1.5, U1.7). The sensors
therefore need to communicate with the climate control system. Since
a wrong sensor value leads to a wrong temperature and thus to spoiled
goods, the integrity of the sensor data must be assured (U1.2, U1.3).
The banana boxes within a container will in most cases belong to the
same owner. Adjacent containers might contain goods and sensors of
different owners (U1.1).
The personnel that transloads the goods must be able to locate the
goods meant for a specific customer (U1.1, U1.6, U1.7). However the
fruit vendor does not want to disclose sensor information pertaining
to the condition of the goods to other companies and therefore wants
to assure the confidentiality of this data (U1.4). Thus, the
transloading personnel is only allowed to access logistic information
(U1.1). Moreover, the transloading personnel is only allowed to
access the data for the time of the transloading (U1.8).
Due to the high water content of the fruits, the propagation of radio
waves is hindered, thus often inhibiting direct communication between
nodes [Jedermann14]. Instead, messages are forwarded over multiple
hops (U1.9). The sensors in the banana boxes cannot always reach the
Internet during the journey (U1.10). Sensors may need to use relay
stations owned by the transport company to connect to endpoints in
the Internet.
In the ripening facility bananas are stored until they are ready to
be sold. The banana box sensors are used to control the ventilation
system and to monitor the degree of ripeness of the bananas. Ripe
bananas need to be identified and sold before they spoil (U1.2,
U1.8).
Seitz, et al. Expires April 25, 2016 [Page 5]
Internet-Draft ACE Use Cases October 2015
The supermarket chain gains ownership of the banana boxes when the
bananas have ripened and are ready to leave the ripening facility.
2.1.2. Authorization Problems Summary
o U1.1 Fruit vendors and container owners want to grant different
authorizations for their resources and/or endpoints to different
parties.
o U1.2 The fruit vendor requires the integrity and authenticity of
the sensor data that pertains the state of the goods for climate
control and to ensure the quality of the monitored recordings.
o U1.3 The container owner requires the integrity and authenticity
of the sensor data that is used for climate control.
o U1.4 The fruit vendor requires the confidentiality of the sensor
data that pertains the state of the goods and the confidentiality
of location data, e.g., to protect them from targeted attacks from
competitors.
o U1.5 The fruit vendor may need different protection for several
different types of data on the same endpoint, e.g., sensor data
and the data used for logistics.
o U1.6 The fruit vendor and the transloading personnel require the
authenticity and integrity of the data that is used to locate the
goods, in order to ensure that the goods are correctly treated and
delivered.
o U1.7 The container owner and the fruit vendor may not be present
at the time of access and cannot manually intervene in the
authorization process.
o U1.8 The fruit vendor, container owner and transloading company
want to grant temporary access permissions to a party, in order to
avoid giving permanent access to parties that are no longer
involved in processing the bananas.
o U1.9 The fruit vendor, container owner and transloading company
want their security objectives to be achieved, even if the
messages between the endpoints need to be forwarded over multiple
hops.
o U1.10 The constrained devices might not always be able to reach
the Internet but still need to enact the authorization policies of
their principals.
Seitz, et al. Expires April 25, 2016 [Page 6]
Internet-Draft ACE Use Cases October 2015
o U1.11 Fruit vendors and container owners want to be able to revoke
authorization on a malfunctioning sensor.
2.2. Home Automation
One application of the Internet of Things is home automation systems.
Such a system can connect household devices that control, for example
heating, ventilation, lighting, home entertainment, and home security
to the Internet making them remotely accessible and manageable.
Such a system needs to accommodate a number of regular users
(inhabitants, close friends, cleaning personnel) as well as a
heterogeneous group of dynamically varying users (visitors,
repairmen, delivery men).
As the users are not typically trained in security (or even computer
use), the configuration must use secure default settings, and the
interface must be well adapted to novice users.
2.2.1. Controlling the Smart Home Infrastructure
Alice and Bob own a flat which is equipped with home automation
devices such as HVAC and shutter control, and they have a motion
sensor in the corridor which controls the light bulbs there (U2.5).
Alice and Bob can control the shutters and the temperature in each
room using either wall-mounted touch panels or an internet connected
device (e.g. a smartphone). Since Alice and Bob both have a full-
time job, they want to be able to change settings remotely, e.g. turn
up the heating on a cold day if they will be home earlier than
expected (U2.5).
The couple does not want people in radio range of their devices, e.g.
their neighbors, to be able to control them without authorization.
Moreover, they don't want burglars to be able to deduce behavioral
patterns from eavesdropping on the network (U2.8).
2.2.2. Seamless Authorization
Alice buys a new light bulb for the corridor and integrates it into
the home network, i.e. makes resources known to other devices in the
network. Alice makes sure that the new light bulb and her other
devices in the network get to know the authorization policies for the
new device. Bob is not at home, but Alice wants him to be able to
control the new device with his devices (e.g. his smartphone) without
the need for additional administration effort (U2.7). She provides
the necessary configurations for that (U2.9, U2.10).
Seitz, et al. Expires April 25, 2016 [Page 7]
Internet-Draft ACE Use Cases October 2015
2.2.3. Remotely letting in a visitor
Alice and Bob have equipped their home with automated connected door-
locks and an alarm system at the door and the windows. The couple
can control this system remotely.
Alice and Bob have invited Alice's parents over for dinner, but are
stuck in traffic and cannot arrive in time, while Alice's parents who
use the subway will arrive punctually. Alice calls her parents and
offers to let them in remotely, so they can make themselves
comfortable while waiting (U2.1, U2.6). Then Alice sets temporary
permissions that allow them to open the door, and shut down the alarm
(U2.2). She wants these permissions to be only valid for the evening
since she does not like it if her parents are able to enter the house
as they see fit (U2.3, U2.4).
When Alice's parents arrive at Alice's and Bob's home, they use their
smartphone to communicate with the door-lock and alarm system (U2.5,
U2.9). The permissions Alice issued to her parents only allow
limited access to the house (e.g. opening the door, turning on the
lights). Certain other functions, such as checking the footage from
the surveillance cameras is not accessible to them (U2.3).
Alice and Bob also issue similarly restricted permissions to e.g.
cleaners, repairmen or their nanny (U2.3).
2.2.4. Selling the house
Alice and Bob have to move because Alice is starting a new job. They
therefore decide to sell the house, and transfer control of all
automated services to the new owners (U2.11). Before doing that they
want to erase privacy relevant data from the logs of the automated
systems, while the new owner is interested to keep some historic data
e.g. pertaining to the behavior of the heating system (U2.12). At
the time of transfer of the house, the new owners also wants make
sure that permissions issued by the previous owners to access the
house or connected devices (in the case where device management may
have separate permissions from house access) are no longer valid
(U2.13).
2.2.5. Authorization Problems Summary
o U2.1 A home owner (Alice and Bob in the example above) wants to
spontaneously provision authorization means to visitors.
o U2.2 A home owner wants to spontaneously change the home's access
control policies.
Seitz, et al. Expires April 25, 2016 [Page 8]
Internet-Draft ACE Use Cases October 2015
o U2.3 A home owner wants to apply different access rights for
different users (including other inhabitants).
o U2.4 The home owners want to grant access permissions to a someone
during a specified time frame.
o U2.5 The smart home devices need to be able to securely
communicate with different control devices (e.g. wall-mounted
touch panels, smartphones, electronic key fobs, device gateways).
o U2.6 The home owner wants to be able to configure authorization
policies remotely.
o U2.7 Authorized Users want to be able to obtain access with little
effort.
o U2.8 The owners of the automated home want to prevent unauthorized
entities from being able to deduce behavioral profiles from
devices in the home network.
o U2.9 Usability is particularly important in this scenario since
the necessary authorization related tasks in the lifecycle of the
device (commissioning, operation, maintenance and decommissioning)
likely need to be performed by the home owners who in most cases
have little knowledge of security.
o U2.10 Home Owners want their devices to seamlessly (and in some
cases even unnoticeably) fulfill their purpose. Therefore the
authorization administration effort needs to be kept at a minimum.
o U2.11 Home Owners want to be able to transfer ownership of their
automated systems when they sell the house.
o U2.12 Home Owners want to be able to sanitize the logs of the
automated systems, when transferring ownership, without deleting
important operational data.
o U2.13 When a transfer of ownership occurs, the new owner wants to
make sure that access rights created by the previous owner are no
longer valid.
2.3. Personal Health Monitoring
Personal health monitoring devices, i.e. eHealth devices, are
typically battery driven and located physically on or in the user to
monitor some bodily function, such as temperature, blood pressure, or
pulse rate. These devices typically connect to the Internet through
an intermediary base-station, using wireless technologies and through
Seitz, et al. Expires April 25, 2016 [Page 9]
Internet-Draft ACE Use Cases October 2015
this connection they report the monitored data to some entity, which
may either be the user, or a medical caregiver.
Medical data has always been considered as very sensitive, and
therefore requires good protection against unauthorized disclosure.
A frequent, conflicting requirement is the capability for medical
personnel to gain emergency access, even if no specific access rights
exist. As a result, the importance of secure audit logs increases in
such scenarios.
Since the users are not typically trained in security (or even
computer use), the configuration must use secure default settings,
and the interface must be well adapted to novice users. Parts of the
system must operate with minimal maintenance. Especially frequent
changes of battery are unacceptable.
There is a plethora of wearable health monitoring technology and the
need for open industry standards to ensure interoperability between
products has lead to initiatives such as Continua Alliance
(continuaalliance.org) and Personal Connected Health Alliance
(pchalliance.org).
2.3.1. John and the heart rate monitor
John has a heart condition, that can result in sudden cardiac
arrests. He therefore uses a device called HeartGuard that monitors
his heart rate and his location (U3.7). In case of a cardiac arrest
it automatically sends an alarm to an emergency service, transmitting
John's current location (U3.1). Either the device has long range
connectivity itself (e.g. via GSM) or it uses some intermediary,
nearby device (e.g. John's smartphone) to transmit such an alarm. To
ensure Johns safety, the device is expected to be in constant
operation (U3.3, U3.6).
The device includes an authentication mechanism, in order to prevent
other persons who get physical access to it from acting as the owner
and altering the access control and security settings (U3.8).
John can configure additional persons that get notified in an
emergency, for example his daughter Jill. Furthermore the device
stores data on John's heart rate, which can later be accessed by a
physician to assess the condition of John's heart (U3.2).
Seitz, et al. Expires April 25, 2016 [Page 10]
Internet-Draft ACE Use Cases October 2015
However John is a privacy conscious person, and is worried that Jill
might use HeartGuard to monitor his location while there is no
emergency. Furthermore he doesn't want his health insurance to get
access to the HeartGuard data, or even to the fact that he is wearing
a HeartGuard, since they might refuse to renew his insurance if they
decided he was too big a risk for them (U3.8).
Finally John, while being comfortable with modern technology and able
to operate it reasonably well, is not trained in computer security.
He therefore needs an interface for the configuration of the
HeartGuard security that is easy to understand and use (U3.5). If
John does not understand the meaning of a setting, he tends to leave
it alone, assuming that the manufacturer has initialized the device
to secure settings (U3.4).
NOTE: Monitoring of some state parameter (e.g. an alarm button) and
the position of a person also fits well into an elderly care service.
This is particularly useful for people suffering from dementia, where
the relatives or caregivers need to be notified of the whereabouts of
the person under certain conditions. In this case it is not the
patient that decides about access.
2.3.2. Authorization Problems Summary
o U3.1 The wearer of an eHealth device (John in the example above)
wants to pre-configure special access rights in the context of an
emergency.
o U3.2 The wearer of an eHealth device wants to selectively allow
different persons or groups access to medical data.
o U3.3 Battery changes are very inconvenient and sometimes
impractical, so battery life impacts of the authorization
mechanisms need to be minimized.
o U3.4 Devices are often used with default access control settings
which might threaten the security objectives of the device's
users.
o U3.5 Wearers of eHealth devices are often not trained in computer
use, and especially computer security.
o U3.6 Security mechanisms themselves could provide opportunities
for denial of service attacks, especially on the constrained
devices.
o U3.7 The device provides a service that can be fatal for the
wearer if it fails. Accordingly, the wearer wants the device to
Seitz, et al. Expires April 25, 2016 [Page 11]
Internet-Draft ACE Use Cases October 2015
have a high degree of resistance against attacks that may cause
the device to fail to operate partially or completely.
o U3.8 The wearer of an eHealth device requires the integrity and
confidentiality of the data measured by the device.
2.4. Building Automation
Buildings for commercial use such as shopping malls or office
buildings nowadays are equipped increasingly with semi-automatic
components to enhance the overall living quality and to save energy
where possible. This includes for example heating, ventilation and
air condition (HVAC) as well as illumination and security systems
such as fire alarms. These components are being increasingly managed
centrally in a Building and Lighting Management System (BLMS) by a
facility manager.
Different areas of these buildings are often exclusively leased to
different companies. However they also share some of the common
areas of the building. Accordingly, a company must be able to
control the lighting and HVAC system of its own part of the building
and must not have access to control rooms that belong to other
companies.
Some parts of the building automation system such as entrance
illumination and fire alarm systems are controlled either by all
parties together or by a facility management company.
2.4.1. Device Lifecycle
2.4.1.1. Installation and Commissioning
Installation of the building automation components often start even
before the construction work is completed. Lighting is one of the
first components to be installed in new buildings. A lighting plan
created by a lighting designer provides the necessary information
related to the kind of lighting devices (luminaires, sensors and
switches) to be installed along with their expected behavior. The
physical installation of the correct lighting devices at the right
locations are done by electricians based on the lighting plan. They
ensure that the electrical wiring is performed according to local
regulations and lighting devices which may be from multiple
manufacturers are connected to the electrical power supply properly.
After the installation, lighting can be used in a default out-of-box
mode for e.g. at full brightness when powered on. After this step
(or in parallel in a different section of the building), a lighting
commissioner adds the devices to the building domain (U4.1) and
performs the proper configuration of the lights as prescribed in the
Seitz, et al. Expires April 25, 2016 [Page 12]
Internet-Draft ACE Use Cases October 2015
lighting plan. This involves for example grouping to ensure that
light points react together, more or less synchronously (U4.8) and
defining lighting scenes for particular areas of the building. The
commissioning is often done in phases, either by one or more
commissioners, on different floors. The building lighting network at
this stage may be in different network islands with no connectivity
between them due to lack of the IT infrastructure.
After this, other building components like HVAC and security systems
are similarly installed by electricians and later commissioned by
their respective domain professionals. Similar configurations
related to grouping (U4.8) are required to ensure for e.g. HVAC
equipment are controlled by the closest temperature sensor.
For the building IT systems, the Ethernet wiring is initially laid
out in the building according to the IT plan. The IT network is
commissioned often after the construction is completed to avoid any
damage to sensitive networking and computing equipment. The
commissioning is performed by an IT engineer with additional switches
(wired and/or wireless), IP routers and computing devices. Direct
Internet connectivity for all installed/commissioned devices in the
building is only available at this point. The BLMS that monitors and
controls the various building automation components are only
connected to the field devices at this stage. The different network
islands (for lighting and HVAC) are also joined together without any
further involvement of domain specialist such as lighting or HVAC
commissioners.
2.4.1.2. Operational
The building automation systems is now finally ready and the
operational access is transferred to the facility management company
of the building (U4.2). The facility manager is responsible for
monitoring and ensuring that the building automation systems meets
the needs of the building occupants. If changes are needed, the
facility management company hires an external installation and
commissioning company to perform the changes.
Different parts of the building are rented out to different companies
for office space.
The tenants are provided access to use the automated HVAC, lighting
and physical access control systems deployed. The safety of the
occupants are also managed using automated systems, such as a fire
alarm system, which is triggered by several smoke detectors which are
spread out across the building.
Company A's staff move into the newly furnished office space. Most
lighting is controlled by presence sensors which control the lighting
Seitz, et al. Expires April 25, 2016 [Page 13]
Internet-Draft ACE Use Cases October 2015
of specific group of lights based on the authorization rules in the
BLMS. Additionally employees are allowed to manually override the
lighting brightness and color in their office rooms by using the
switches or handheld controllers. Such changes are allowed only if
the authorization rules exist in the BLMS. For example lighting in
the corridors may not be manually adjustable.
At the end of the day, lighting is dimmed down or switched off if no
occupancy is detected even if manually overridden during the day.
On a later date company B also moves into the same building, and
shares some of the common spaces and associated building automation
components with company A (U4.2, U4.9).
2.4.1.3. Maintenance
Company A's staff are annoyed that the lighting switches off too
often in their rooms if they work silently in front of their
computer. Company A notifies the the facility manager of the
building to increase the delay before lights switch off. The
facility manager can either configure the new values directly in the
BLMS or if additional changes are needed on the field devices, hires
a commissioning Company C to perform the needed changes (U4.4).
Company C gets the necessary authorization from the facility
management company to interact with the BLMS. The commissioner's
tool gets the necessary authorization from BLMS to send a
configuration change to all lighting devices in Company A's offices
to increase their delay before they switch off.
At some point the facility management company wants to update the
firmware of lighting devices in order to eliminate software bugs.
Before accepting the new firmware, each device checks the
authorization of the facility management company to perform this
update (U4.13).
A network diagnostic tool of the BLMS detects that a luminaire in one
of the Company A's office room is no longer connected to the network.
The BLMS alerts the facility manager to replace the luminaire. The
facility manager replaces the old broken luminaire and informs the
BLMS of the identity (for e.g. MAC address) of the newly added
device. The BLMS then authorizes the new device onto the system and
transfers seamlessly all the permissions of the previous broken
device to the replacement device (U4.12).
2.4.1.4. Recommissioning
Seitz, et al. Expires April 25, 2016 [Page 14]
Internet-Draft ACE Use Cases October 2015
A vacant area of the building has been recently leased to company A.
Before moving into its new office, Company A wishes to replace the
lighting with a more energy efficient and a better light quality
luminaries. They hire an installation and commissioning company C to
redo the illumination. Company C is instructed to integrate the new
lighting devices, which may be from multiple manufacturers, into the
existing lighting infrastructure of the building which includes
presence sensors, switches, controllers etc (U4.1).
Company C gets the necessary authorization from the facility
management company to interact with the existing BLMS (U4.4). To
prevent disturbance to other occupants of the building, Company C is
provided authorization to perform the commissioning only during non-
office hours and only to modify configuration on devices belonging to
the domain of Company A's space (U4.5). Before removing existing
devices, all security and configuration material that belongs to the
domain are deleted and the devices are set back to factory state
(U4.3). This ensures that these devices may be reused at other
installations or in other parts of the same building without
affecting future operations. After installation (wiring) of the new
lighting devices, the commissioner adds the devices into the company
A's lighting domain.
Once the devices are in the correct domain, the commissioner
authorizes the interaction rules between the new lighting devices and
existing devices like presence sensors (U4.7). For this, the
commissioner creates the authorization rules on the BLMS which define
which lights form a group and which sensors/switches/controllers are
allowed to control which groups (U4.8). These authorization rules
may be context based like time of the day (office or non-office
hours) or location of the handheld lighting controller etc (U4.5).
2.4.1.5. Decommissioning
Company A has noticed that the handheld controllers are often
misplaced and hard to find when needed. So most of the time staff
use the existing wall switches for manual control. Company A decides
it would be better to completely remove handheld controllers and asks
Company C to decommission them from the lighting system (U4.4).
Company C again gets the necessary authorization from the facility
management company to interact with the BLMS. The commissioner now
deletes any rules that allowed handheld controllers authorization to
control the lighting (U4.3, U4.6). Additionally the commissioner
instructs the BLMS to push these new rules to prevent cached rules at
the end devices from being used. Any cryptographic key material
belonging to the site in the handheld controllers are also removed
and they are set to the factory state (U4.3).
Seitz, et al. Expires April 25, 2016 [Page 15]
Internet-Draft ACE Use Cases October 2015
2.4.2. Public Safety
The fire department requires that as part of the building safety
code, that the building have sensors that sense the level of smoke,
heat, etc., when a fire breaks out. These sensors report metrics
which are then used by a back-end server to map safe areas and un-
safe areas within a building and also possibly the structural
integrity of the building before fire-fighters may enter it.
Sensors may also be used to track where human/animal activity is
within the building. This will allow people stuck within the
building to be guided to safer areas and suggest possible actions
that they may take (e.g. using a client application on their phones,
or loudspeaker directions) in order to bring them to safety. In
certain cases, other organizations such as the Police, Ambulance, and
federal organizations are also involved and therefore the co-
ordination of tasks between the various entities have to be carried
out using efficient messaging and authorization mechanisms.
2.4.2.1. A fire breaks out
On a really hot day James who works for company A turns on the air
condition in his office. Lucy who works for company B wants to make
tea using an electric kettle. After she turned it on she goes
outside to talk to a colleague until the water is boiling.
Unfortunately, her kettle has a malfunction which causes overheating
and results in a smoldering fire of the kettle's plastic case.
Due to the smoke coming from the kettle the fire alarm is triggered.
Alarm sirens throughout the building are switched on simultaneously
(using a group communication scheme) to alert the staff of both
companies (U4.8). Additionally, the ventilation system of the whole
building is closed off to prevent the smoke from spreading and to
withdraw oxygen from the fire. The smoke cannot get into James'
office although he turned on his air condition because the fire alarm
overrides the manual setting by sending commands (using group
communication) to switch off all the air conditioning (U4.10).
The fire department is notified of the fire automatically and arrives
within a short time. They automatically get access to all parts of
the building according to an emergency authorization policy (U4.4,
U4.5). After inspecting the damage and extinguishing the smoldering
fire a fire fighter resets the fire alarm because only the fire
department is authorized to do that (U4.4, U4.11).
2.4.3. Authorization Problems Summary
Seitz, et al. Expires April 25, 2016 [Page 16]
Internet-Draft ACE Use Cases October 2015
o U4.1 During commissioning, the building owner or the companies add
new devices to their administrative domain. Access control should
then apply to these devices seamlessly.
o U4.2 During a handover, the building owner or the companies
integrate devices that formerly belonged to a different
administrative domain to their own administrative domain. Access
control of the old domain should then cease to apply, with access
control of the new domain taking over.
o U4.3 During decommissioning, the building owner or the companies
remove devices from their administrative domain. Access control
should cease to apply to these devices and relevant credentials
need to be erased from the devices.
o U4.4 The building owner and the companies want to be able to
delegate specific access rights for their devices to others.
o U4.5 The building owner and the companies want to be able to
define context-based authorization rules.
o U4.6 The building owner and the companies want to be able to
revoke granted permissions and delegations.
o U4.7 The building owner and the companies want to allow authorized
entities to send data to their endpoints (default deny).
o U4.8 The building owner and the companies want to be able to
authorize a device to control several devices at the same time
using a group communication scheme.
o U4.9 The companies want to be able to interconnect their own
subsystems with those from a different operational domain while
keeping the control over the authorizations (e.g. granting and
revoking permissions) for their endpoints and devices.
o U4.10 The authorization mechanisms must be able to cope with
extremely time-sensitive operations which have to be carried out
in a quick manner.
o U4.11 The building owner and the public safety authorities want to
be able to perform data origin authentication on messages sent and
received by some of the systems in the building.
o U4.12 The building owner should be allowed to replace an existing
device with a new device providing the same functionality within
their administrative domain. Access control from the replaced
device should then apply to these new devices seamlessly.
Seitz, et al. Expires April 25, 2016 [Page 17]
Internet-Draft ACE Use Cases October 2015
o U4.13 When software on a device is updated, this update needs to
be authenticated and authorized.
2.5. Smart Metering
Automated measuring of customer consumption is an established
technology for electricity, water, and gas providers. Increasingly
these systems also feature networking capability to allow for remote
management. Such systems are in use for commercial, industrial and
residential customers and require a certain level of security, in
order to avoid economic loss to the providers, vulnerability of the
distribution system, as well as disruption of services for the
customers.
The smart metering equipment for gas and water solutions is battery
driven and communication should be used sparingly due to battery
consumption. Therefore the types of meters sleep most of the time,
and only wake up every minute/hour to check for incoming
instructions. Furthermore they wake up a few times a day (based on
their configuration) to upload their measured metering data.
Different networking topologies exist for smart metering solutions.
Based on environment, regulatory rules and expected cost, one or a
mixture of these topologies may be deployed to collect the metering
information. Drive-By metering is one of the most current solutions
deployed for collection of gas and water meters.
Various stakeholders have a claim on the metering data. Utility
companies need the data for accounting, the metering equipment may be
operated by a third party Service Operator who needs to maintain it,
and the equipment is installed in the premises of the consumers,
measuring their consumption, which entails privacy questions.
2.5.1. Drive-by metering
A service operator offers smart metering infrastructures and related
services to various utility companies. Among these is a water
provider, who in turn supplies several residential complexes in a
city. The smart meters are installed in the end customer's homes to
measure water consumption and thus generate billing data for the
utility company, they can also be used to shut off the water if the
bills are not paid (U5.1, U5.3). The meters do so by sending and
receiving data to and from a base station (U5.2). Several base
stations are installed around the city to collect the metering data.
However in the denser urban areas, the base stations would have to be
installed very close to the meters. This would require a high number
of base stations and expose this more expensive equipment to
manipulation or sabotage. The service operator has therefore chosen
Seitz, et al. Expires April 25, 2016 [Page 18]
Internet-Draft ACE Use Cases October 2015
another approach, which is to drive around with a mobile base-station
and let the meters connect to that in regular intervals in order to
gather metering data (U5.4, U5.6, U5.8).
2.5.2. Meshed Topology
In another deployment, the water meters are installed in a building
that already has power meters installed, the latter are mains
powered, and are therefore not subject to the same power saving
restrictions. The water meters can therefore use the power meters as
proxies, in order to achieve better connectivity. This requires the
security measures on the water meters to work through intermediaries
(U5.9).
2.5.3. Advanced Metering Infrastructure
A utility company is updating its old utility distribution network
with advanced meters and new communication systems, known as an
Advanced Metering Infrastructure (AMI). AMI refers to a system that
measures, collects and analyzes usage, and interacts with metering
devices such as electricity meters, gas meters, heat meters, and
water meters, through various communication media either on request
(on-demand) or on pre-defined schedules. Based on this technology,
new services make it possible for consumers to control their utility
consumption (U5.2, U5.7) and reduce costs by supporting new tariff
models from utility companies, and more accurate and timely billing.
However the end-consumers do not want unauthorized persons to gain
access to this data. Furthermore, the fine-grained measurement of
consumption data may induce privacy concerns, since it may allow
others to create behavioral profiles (U5.5, U5.10).
The technical solution is based on levels of data aggregation between
smart meters located at the consumer premises and the Meter Data
Management (MDM) system located at the utility company (U5.9). For
reasons of efficiency and cost, end-to-end connectivity is not always
feasible, so metering data is stored and aggregated in various
intermediate devices before being forwarded to the utility company,
and in turn accessed by the MDM. The intermediate devices may be
operated by a third party service operator on behalf of the utility
company (U5.7). One responsibility of the service operator is to
make sure that meter readings are performed and delivered in a
regular, timely manner. An example of a Service Level Agreement
between the service operator and the utility company is e.g. "at
least 95 % of the meters have readings recorded during the last 72
hours".
2.5.4. Authorization Problems Summary
Seitz, et al. Expires April 25, 2016 [Page 19]
Internet-Draft ACE Use Cases October 2015
o U5.1 Devices are installed in hostile environments where they are
physically accessible by attackers (including dishonest
customers). The service operator and the utility company want to
make sure that an attacker cannot use data from a captured device
to attack other parts of their infrastructure.
o U5.2 The utility company wants to control which entities are
allowed to send data to, and read data from their endpoints.
o U5.3 The utility company wants to ensure the integrity of the data
stored on their endpoints.
o U5.4 The utility company wants to protect such data transfers to
and from their endpoints.
o U5.5 Consumers want to access their own usage information and also
prevent unauthorized access by others.
o U5.6 The devices may have intermittent Internet connectivity but
still need to enact the authorization policies of their
principals.
o U5.7 Neither the service operator nor the utility company are
always present at the time of access and cannot manually intervene
in the authorization process.
o U5.8 When authorization policies are updated it is impossible, or
at least very inefficient to contact all affected endpoints
directly.
o U5.9 Authorization and authentication must work even if messages
between endpoints are stored and forwarded over multiple nodes.
o U5.10 Consumers may not want the Service Operator, the Utility
company or others to have access to a fine-grained level of
consumption data that allows the creation of behavioral profiles.
2.6. Sports and Entertainment
In the area of leisure time activities, applications can benefit from
the small size and weight of constrained devices. Sensors and
actuators with various functions can be integrated into fitness
equipment, games and even clothes. Users can carry their devices
around with them at all times.
Seitz, et al. Expires April 25, 2016 [Page 20]
Internet-Draft ACE Use Cases October 2015
Usability is especially important in this area since users will often
want to spontaneously interconnect their devices with others.
Therefore the configuration of access permissions must be simple and
fast and not require much effort at the time of access.
Continuously monitoring allows authorized users to create behavioral
or movement profiles, which corresponds on the devices intended use,
and unauthorized access to the collected data would allow an attacker
to create the same profiles.
Moreover, the aggregation of data can seriously increase the impact
on the privacy of the users.
2.6.1. Dynamically Connecting Smart Sports Equipment
Jody is a an enthusiastic runner. To keep track of her training
progress, she has smart running shoes that measure the pressure at
various points beneath her feet to count her steps, detect
irregularities in her stride and help her to improve her posture and
running style. On a sunny afternoon, she goes to the Finnbahn track
near her home to work out. She meets her friend Lynn who shows her
the smart fitness watch she bought a few days ago. The watch can
measure the wearer's pulse, show speed and distance, and keep track
of the configured training program. The girls detect that the watch
can be connected with Jody's shoes and then can additionally display
the information the shoes provide.
Jody asks Lynn to let her try the watch and lend it to her for the
afternoon. Lynn agrees but doesn't want Jody to access her training
plan (U6.4). She configures the access policies for the watch so
that Jody's shoes are allowed to access the display and measuring
features but cannot read or add training data (U6.1, U6.2). Jody's
shoes connect to Lynn's watch after only a press of a button because
Jody already configured access rights for devices that belong to Lynn
a while ago (U6.3). Jody wants the device to report the data back to
her fitness account while she borrows it, so she allows it to access
her account temporarily.
After an hour, Jody gives the watch back and both girls terminate the
connection between their devices.
2.6.2. Authorization Problems Summary
o U6.1 Sports equipment owners want to be able to grant access
rights dynamically when needed.
o U6.2 Sports equipment owners want the configuration of access
rights to work with very little effort.
Seitz, et al. Expires April 25, 2016 [Page 21]
Internet-Draft ACE Use Cases October 2015
o U6.3 Sports equipment owners want to be able to pre-configure
access policies that grant certain access permissions to endpoints
with certain attributes (e.g. endpoints of a certain user) without
additional configuration effort at the time of access.
o U6.4 Sports equipment owners want to protect the confidentiality
of their data for privacy reasons.
2.7. Industrial Control Systems
Industrial control systems (ICS) and especially supervisory control
and data acquisition systems (SCADA) use a multitude of sensors and
actuators in order to monitor and control industrial processes in the
physical world. Example processes include manufacturing, power
generation, and refining of raw materials.
Since the advent of the Stuxnet worm it has become obvious to the
general public how vulnerable these kind of systems are, especially
when connected to the Internet [Karnouskos11]. The severity of these
vulnerabilities are exacerbated by the fact that many ICS are used to
control critical public infrastructure, such as nuclear power, water
treatment of traffic control. Nevertheless the economical advantages
of connecting such systems to the Internet can be significant if
appropriate security measures are put in place (U7.5).
2.7.1. Oil Platform Control
An oil platform uses an industrial control system to monitor data and
control equipment. The purpose of this system is to gather and
process data from a large number of sensors, and control actuators
such as valves and switches to steer the oil extraction process on
the platform. Raw data, alarms, reports and other information are
also available to the operators, who can intervene with manual
commands. Many of the sensors are connected to the controlling units
by direct wire, but the operator is slowly replacing these units by
wireless ones, since this makes maintenance easier (U7.4).
Some of the controlling units are connected to the Internet, to allow
for remote administration, since it is expensive and inconvenient to
fly in a technician to the platform (U7.3).
The main interest of the operator is to ensure the integrity of
control messages and sensor readings (U7.1). Access in some cases
needs to be restricted, e.g. the operator wants wireless actuators
only to accept commands by authorized control units (U7.2).
The owner of the platform also wants to collect auditing information
for liability reasons (U7.1).
Seitz, et al. Expires April 25, 2016 [Page 22]
Internet-Draft ACE Use Cases October 2015
Different levels of access apply e.g. for regular operators, vs.
maintenance technician, vs. auditors of the platform (U7.6)
2.7.2. Authorization Problems Summary
o U7.1 The operator of the platform wants to ensure the integrity
and confidentiality of sensor and actuator data.
o U7.2 The operator wants to ensure that data coming from sensors
and commands sent to actuators are authentic.
o U7.3 Some devices do not have direct Internet connection, but
still need to implement current authorization policies.
o U7.4 Devices need to authenticate the controlling units,
especially those using a wireless connection.
o U7.5 The execution of unauthorized commands or the failure to
execute an authorized command in an ICS can lead to significant
financial damage, and threaten the availability of critical
infrastructure services. Accordingly, the operator wants a
authentication and authorization mechanisms that provide a very
high level of security.
o U7.6 Different users should have different levels of access to the
control system (e.g. operator vs. auditor).
3. Security Considerations
As the use cases listed in this document demonstrate, constrained
devices are used in various environments. These devices are small
and inexpensive and this makes it easy to integrate them into many
aspects of everyday life. With access to vast amounts of valuable
data and possibly control of important functions these devices need
to be protected from unauthorized access. Protecting seemingly
innocuous data and functions will lessen the possible effects of
aggregation; attackers collecting data or functions from several
sources can gain insights or a level of control not immediately
obvious from each of these sources on its own.
Not only the data on the constrained devices themselves is
threatened, the devices might also be abused as an intrusion point to
infiltrate a network. Once an attacker gains control over the
device, it can be used to attack other devices as well. Due to their
limited capabilities, constrained devices appear as the weakest link
in the network and hence pose an attractive target for attackers.
Seitz, et al. Expires April 25, 2016 [Page 23]
Internet-Draft ACE Use Cases October 2015
This section summarizes the security problems highlighted by the use
cases above and provides guidelines for the design of protocols for
authentication and authorization in constrained RESTful environments.
3.1. Attacks
This document lists security problems that users of constrained
devices want to solve. Further analysis of attack scenarios is not
in scope of the document. However, there are attacks that must be
considered by solution developers.
Because of the expected large number of devices and their ubiquity,
constrained devices increase the danger from Pervasive Monitoring
[RFC7258] attacks. Solution Designers should consider this in the
design of their security solution and provide for protection against
this type of attack. In particular, messages containing sensitive
data that are send over unprotected channels should be encrypted if
possible.
Attacks aimed at altering data in transit (e.g. to perpetrate fraud)
are a problem that is addressed in many web security protocols such
as TLS or IPSec. Developers need to consider this type of attacks,
and make sure that the protection measures they implement are adapted
to the constrained environment.
As some of the use cases indicate, constrained devices may be
installed in hostile environments where they are physically
accessible (see Section 2.5). Protection from physical attacks is
not in the scope of this document, but should be kept in mind by
developers of authorization solutions.
Denial of service (DoS) attacks threaten the availability of services
a device provides and constrained devices are especially vulnerable
to these types of attacks because of their limitations. Attackers
can illicit a temporary or, if the battery is drained, permanent
failure in a service simply by repeatedly flooding the device with
connection attempts; for some services (see section Section 2.3),
availability is especially important. Solution designers must be
particularly careful to consider the following limitations in every
part of the authorization solution:
o Battery usage
o Number of required message exchanges
o Size of data that is transmitted (e.g. authentication and access
control data)
Seitz, et al. Expires April 25, 2016 [Page 24]
Internet-Draft ACE Use Cases October 2015
o Size of code required to run the protocols
o Size of RAM memory and stack required to run the protocols
o Resources blocked by partially completed exchanges (e.g. while one
party is waiting for a transaction time to run out)
Solution developers also need to consider whether the session should
be protected from information disclosure and tampering.
3.2. Configuration of Access Permissions
o The access control policies need to be enforced (all use cases):
The information that is needed to implement the access control
policies needs to be provided to the device that enforces the
authorization and applied to every incoming request.
o A single resource might have different access rights for different
requesting entities (all use cases).
Rationale: In some cases different types of users need different
access rights, as opposed to a binary approach where the same
access permissions are granted to all authenticated users.
o A device might host several resources where each resource has its
own access control policy (all use cases).
o The device that makes the policy decisions should be able to
evaluate context-based permissions such as location or time of
access (see Section 2.2, Section 2.3, Section 2.4). Access may
depend on local conditions, e.g. access to health data in an
emergency. The device that makes the policy decisions should be
able to take such conditions into account.
3.3. Authorization Considerations
o Devices need to be enabled to enforce authorization policies
without human intervention at the time of the access request (see
Section 2.1, Section 2.2, Section 2.4, Section 2.5).
o Authorization solutions need to consider that constrained devices
might not have internet access at the time of the access request
(see Section 2.1, Section 2.3, Section 2.5, Section 2.6).
o It should be possible to update access control policies without
manually re-provisioning individual devices (see Section 2.2,
Section 2.3, Section 2.5, Section 2.6).
Seitz, et al. Expires April 25, 2016 [Page 25]
Internet-Draft ACE Use Cases October 2015
Rationale: Peers can change rapidly which makes manual re-
provisioning unreasonably expensive.
o Authorization policies may be defined to apply to a large number
of devices that might only have intermittent connectivity.
Distributing policy updates to every device for every update might
not be a feasible solution (see Section 2.5).
o It must be possible to dynamically revoke authorizations (see e.g.
Section 2.4).
o The authentication and access control protocol can put undue
burden on the constrained system resources of a device
participating in the protocol. An authorization solutions must
take the limitations of the constrained devices into account (all
use cases, see also Section 3.1).
o Secure default settings are needed for the initial state of the
authentication and authorization protocols (all use cases).
Rationale: Many attacks exploit insecure default settings, and
experience shows that default settings are frequently left
unchanged by the end users.
o Access to resources on other devices should only be permitted if a
rule exists that explicitly allows this access (default deny) (see
e.g. Section 2.4).
o Usability is important for all use cases. The configuration of
authorization policies as well as the gaining access to devices
must be simple for the users of the devices. Special care needs
to be taken for scenarios where access control policies have to be
configured by users that are typically not trained in security
(see Section 2.2, Section 2.3, Section 2.6).
o Software updates are an important operation for which correct
authorization is crucial. Additionally authenticating the
receiver of a software update is also important, for example to
make sure that the update has been received by the intended
device.
3.4. Proxies
In some cases, the traffic between endpoints might go through
intermediary nodes (e.g. proxies, gateways). This might affect the
function or the security model of authentication and access control
protocols e.g. end-to-end security between endpoints with DTLS might
not be possible (see Section 2.5).
Seitz, et al. Expires April 25, 2016 [Page 26]
Internet-Draft ACE Use Cases October 2015
4. Privacy Considerations
The constrained devices in focus of this document collect data from
the physical world via sensors or affect their surrounding via
actuators. The collected and processed data often can be associated
with individuals. Since sensor data may be collected and distributed
on a regular interval a significant amount of information about an
individual can be collected and used as input to learning algorithms
as part of big data analysis and used in an automated decision making
process.
Offering privacy protection for individuals is important to guarantee
that only authorized entities are allowed to access collected data
and to trigger actions, to obtain consent prior to the sharing of
data, and to deal with other privacy-related threats outlined in RFC
6973.
RFC 6973 was written as guidance for engineers designing technical
solutions. For a short description about the deployment-related
aspects of privacy and further references relevant for the Internet
of Things sector please read Section 7 of RFC 7452.
5. Acknowledgments
The authors would like to thank Olaf Bergmann, Sumit Singhal, John
Mattson, Mohit Sethi, Carsten Bormann, Martin Murillo, Corinna
Schmitt, Hannes Tschofenig, Erik Wahlstroem, Andreas Baeckman, Samuel
Erdtman, Steve Moore, Thomas Hardjono, Kepeng Li, Jim Schaad,
Prashant Jhingran, Kathleen Moriarty, and Sean Turner for reviewing
and/or contributing to the document. Also, thanks to Markus Becker,
Thomas Poetsch and Koojana Kuladinithi for their input on the
container monitoring use case. Furthermore the authors thank Akbar
Rahman, Chonggang Wang, Vinod Choyi, and Abhinav Somaraju who
contributed to the building automation use case.
Ludwig Seitz and Goeran Selander worked on this document as part of
EIT-ICT Labs activity PST-14056.
6. IANA Considerations
This document has no IANA actions.
7. Informative References
[Jedermann14]
Jedermann, R., Poetsch, T., and C. LLoyd, "Communication
techniques and challenges for wireless food quality
monitoring", Philosophical Transactions of the Royal
Seitz, et al. Expires April 25, 2016 [Page 27]
Internet-Draft ACE Use Cases October 2015
Society A Mathematical, Physical and Engineering Sciences,
May 2014.
[Karnouskos11]
Karnouskos, S., "Stuxnet Worm Impact on Industrial Cyber-
Physical System Security", IECON 2011 - 37th Annual
Conference on IEEE Industrial Electronics Society, pp.
4490-4494 , November 2011.
[RFC7228] Bormann, C., Ersue, M., and A. Keranen, "Terminology for
Constrained-Node Networks", RFC 7228, DOI 10.17487/
RFC7228, May 2014,
<http://www.rfc-editor.org/info/rfc7228>.
[RFC7252] Shelby, Z., Hartke, K., and C. Bormann, "The Constrained
Application Protocol (CoAP)", RFC 7252, DOI 10.17487/
RFC7252, June 2014,
<http://www.rfc-editor.org/info/rfc7252>.
[RFC7258] Farrell, S. and H. Tschofenig, "Pervasive Monitoring Is an
Attack", BCP 188, RFC 7258, DOI 10.17487/RFC7258, May
2014, <http://www.rfc-editor.org/info/rfc7258>.
Authors' Addresses
Ludwig Seitz (editor)
SICS Swedish ICT AB
Scheelevaegen 17
Lund 223 70
Sweden
Email: ludwig@sics.se
Stefanie Gerdes (editor)
Universitaet Bremen TZI
Postfach 330440
Bremen 28359
Germany
Phone: +49-421-218-63906
Email: gerdes@tzi.org
Seitz, et al. Expires April 25, 2016 [Page 28]
Internet-Draft ACE Use Cases October 2015
Goeran Selander
Ericsson
Faroegatan 6
Kista 164 80
Sweden
Email: goran.selander@ericsson.com
Mehdi Mani
Itron
52, rue Camille Desmoulins
Issy-les-Moulineaux 92130
France
Email: Mehdi.Mani@itron.com
Sandeep S. Kumar
Philips Research
High Tech Campus
Eindhoven 5656 AA
The Netherlands
Email: sandeep.kumar@philips.com
Seitz, et al. Expires April 25, 2016 [Page 29]