Internet DRAFT - draft-rosen-bess-pta-flags
draft-rosen-bess-pta-flags
BESS Working Group E. Rosen
Internet-Draft Juniper Networks, Inc.
Updates: 6514 (if approved) February 11, 2015
Intended status: Standards Track
Expires: August 15, 2015
IANA Registry for P-Multicast Service Interface Tunnel Attribute Flags
draft-rosen-bess-pta-flags-00.txt
Abstract
RFC6514 defines the "P-Multicast Service Interface Tunnel (PMSI
Tunnel) attribute". This attribute contains an octet of "flags".
Only one flag is defined in that RFC, but there is now a need to
define additional flags. Since the RFC did not create a registry for
the assignment of flag bits, this document updates the RFC by
creating a registry for that purpose.
Status of This Memo
This Internet-Draft is submitted in full conformance with the
provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF). Note that other groups may also distribute
working documents as Internet-Drafts. The list of current Internet-
Drafts is at http://datatracker.ietf.org/drafts/current/.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
This Internet-Draft will expire on August 15, 2015.
Copyright Notice
Copyright (c) 2015 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
Rosen Expires August 15, 2015 [Page 1]
Internet-Draft PMSI Tunnel Attribute Flags February 2015
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . 2
2. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 2
3. Security Considerations . . . . . . . . . . . . . . . . . . . 3
4. Normative References . . . . . . . . . . . . . . . . . . . . 3
Author's Address . . . . . . . . . . . . . . . . . . . . . . . . 3
1. Introduction
[RFC6514] defines the "P-Multicast Service Interface Tunnel (PMSI
Tunnel) attribute". This attribute contains an octet of "flags".
Only one flag is defined in that RFC, but there is now a need to
define additional flags. Since the RFC did not create a registry for
the assignment of flag bits, this document creates a registry for
that purpose.
2. IANA Considerations
IANA is requested to create a new registry called "P-Multicast
Service Interface Tunnel (PMSI Tunnel) Attribute Flags" in the
"Border Gateway Protocol (BGP) Parameters" registry.
Per [RFC6514] section 5, a PMSI Tunnel Attribute contains a "Flags"
octet. The Flags field is a single octet, with bits numbered, left-
to-right, from 0 to 7. IANA is requested to initialize the registry
as follows:
Rosen Expires August 15, 2015 [Page 2]
Internet-Draft PMSI Tunnel Attribute Flags February 2015
Bit Position Description Reference
(left to right)
0 unassigned
1 unassigned
2 unassigned
3 unassigned
4 unassigned
5 unassigned
6 unassigned
7 Leaf Information Required (LIR) RFC6514
PMSI Tunnel Attribute Flags
The registration procedure for this registry is Standards Action.
3. Security Considerations
No security considerations are raised by this document.
4. Normative References
[RFC6514] Aggarwal, R., Rosen, E., Morin, T., and Y. Rekhter, "BGP
Encodings and Procedures for Multicast in MPLS/BGP IP
VPNs", RFC 6514, February 2012.
Author's Address
Eric C. Rosen
Juniper Networks, Inc.
10 Technology Park Drive
Westford, Massachusetts 01886
USA
Email: erosen@juniper.net
Rosen Expires August 15, 2015 [Page 3]