Internet DRAFT - draft-wu-netconf-restconf-factory-restore
draft-wu-netconf-restconf-factory-restore
NETCONF Working Group Q. Wu
Internet-Draft Huawei
Intended status: Standards Track B. Lengyel
Expires: April 14, 2019 Ericsson Hungary
Y. Niu
Huawei
October 11, 2018
Factory default Setting
draft-wu-netconf-restconf-factory-restore-03
Abstract
This document defines a method to reset a YANG datastore to its
factory-default content. The reset operation may be used e.g. during
initial zero-touch configuration or when the existing configuration
has major errors, so re-starting the configuration process from
scratch is the best option.
A new reset-datastore RPC is defined. Several methods of documenting
the factory-default content are specified.
Optionally a new "factory-default" read-only datastore is defined,
that contains the data that will be copied over to the running
datastore at reset.
Status of This Memo
This Internet-Draft is submitted in full conformance with the
provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF). Note that other groups may also distribute
working documents as Internet-Drafts. The list of current Internet-
Drafts is at https://datatracker.ietf.org/drafts/current/.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
This Internet-Draft will expire on April 14, 2019.
Wu, et al. Expires April 14, 2019 [Page 1]
Internet-Draft Factory Default Setting October 2018
Copyright Notice
Copyright (c) 2018 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(https://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1. Terminology . . . . . . . . . . . . . . . . . . . . . . . 3
2. Reset-Datastore RPC . . . . . . . . . . . . . . . . . . . . . 3
3. Factory-Default Datastore . . . . . . . . . . . . . . . . . . 4
4. YANG Module . . . . . . . . . . . . . . . . . . . . . . . . . 5
5. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 7
6. Security Considerations . . . . . . . . . . . . . . . . . . . 7
7. Acknowledgements . . . . . . . . . . . . . . . . . . . . . . 8
8. Contributors . . . . . . . . . . . . . . . . . . . . . . . . 8
9. References . . . . . . . . . . . . . . . . . . . . . . . . . 8
9.1. Normative References . . . . . . . . . . . . . . . . . . 8
9.2. Informative References . . . . . . . . . . . . . . . . . 9
Appendix A. Open Issues . . . . . . . . . . . . . . . . . . . . 9
Appendix B. Changes between revisions . . . . . . . . . . . . . 9
Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . 9
1. Introduction
This document defines a method to reset a YANG datastore to its
factory-default content. The reset operation may be used e.g. during
initial zero-touch configuration or when the existing configuration
has major errors, so re-starting the configuration process from
scratch is the best option. When resetting a datastore all previous
configuration settings will be lost and replaced by the factory-
default content.
A new reset-datastore RPC is defined. Several methods of documenting
the factory-default content are specified.
Optionally a new "factory-default" read-only datastore is defined,
that contains the data that will be copied over to the running
Wu, et al. Expires April 14, 2019 [Page 2]
Internet-Draft Factory Default Setting October 2018
datastore at reset. This datastore can be used in <get-data> or
<copy-config> operations.
NETCONF defines the <delete> operation that allows resetting the
<startup> datastore, and the <discard-changes> operation that copies
the content of the <running> datastore into the <candidate>
datastore. However it is not possible to reset the running
datastore, to reset the candidate datastore without changing the
running datastore or to reset any dynamic datastore.
A RESTCONF server MAY implement the above NETCONF operations, but
that would still not allow it to reset the running configuration.
1.1. Terminology
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
"OPTIONAL" in this document are to be interpreted as described in BCP
14 [RFC2119] [RFC8174] when, and only when, they appear in all
capitals, as shown here.
The following terms are defined in [RFC8342] and are not redefined
here:
o startup configuration datastore
o candiate configuration datastore
o running configuration datastore
o intended configuration datastore
o operational state datastore
The following terms are defined in this document as follows:
o factory-default datastore: A read-only datastore holding a
preconfigured minimal initial configuration that can be used to
initialize the configuration of a server. The content of the
datastore is usually static, but MAY depend on external factors
like available HW.
2. Reset-Datastore RPC
A new "reset-datastore" RPC is introduced. It will have a target
datastore as a parameter. Upon receiveing the RPC the YANG server
resets the content of the target datastore to its factory-default
content. Only writable datastores can be specified as a target.
Wu, et al. Expires April 14, 2019 [Page 3]
Internet-Draft Factory Default Setting October 2018
Read-only datastores receive their content from other datastores
(e.g. <intended> gets its content from <running>).
Factory-default content SHALL be specified by one of the following
means in order of precedence
1. For the <running>, <candidate> and <startup> datastores as the
content of the <factory-default> datastore, if it exists
2. YANG Instance Data [I-D.lengyel-netmod-yang-instance-data]
3. In some implementation specific manner
4. For dynamic datastores unless otherwise specified the factory-
default content is empty.
3. Factory-Default Datastore
This document introduces a new datastore resource named 'Factory-
Default' that represents a preconfigured minimal initial
configuration that can be used to initialize the configuration of a
server.
o Name: "factory-default"
o YANG modules: all
o YANG nodes: all "config true" data nodes
o Management operations: The content of the datastore is set by the
YANG server in an implementation dependent manner. The content
can not be changed by management operations via NETCONF, RESTCONF,
the CLI etc. unless specialized, dedicated operations are
provided. The contents of the datastore can be read using
NETCONF, RESTCONF <get-data> operation. The operations <reset-
datastore> or <copy-config> can be used to copy the content of the
datastore to another datastore. The content of the datastore is
not propagated auomatically to any other datastores.
o Origin: This document does not define a new origin identity as it
does not interact with <operational> datastore.
o Protocols: All e.g. Restconf, Netconf
o Defining YANG module: "ietf-factory-reset"
Wu, et al. Expires April 14, 2019 [Page 4]
Internet-Draft Factory Default Setting October 2018
The datastore content is usually defined by the device vendor. It is
usually static, but MAY change e.g. depending on external factors
like HW available or during device upgrade.
On devices that support non-volatile storage, the contents of
<factory > MUST persist across restarts
4. YANG Module
<CODE BEGINS> file "ietf-factory-reset.yang"
module ietf-factory-reset {
yang-version 1.1;
namespace urn:ietf:params:xml:ns:yang:ietf-factory-reset ;
prefix fres ;
import ietf-netconf { prefix nc ; }
import ietf-datastores { prefix ds; }
organization
"IETF NETCONF (Network Configuration) Working Group";
contact
"WG Web: <https://tools.ietf.org/wg/netconf/>
WG List: <mailto:netconf@ietf.org>
WG Chair: Kent Watsen
<mailto:kwatsen@juniper.net>
WG Chair: Mahesh Jethanandani
<mailto:mjethanandani@gmail.com>
Editor: Balazs Lengyel
<mailto:balazs.lengyel@ericsson.com>
Editor: Qin Wu
<mailto:bill.wu@huawei.com>";
description
"This module defines the
- reset-datastore RPC
- factory-default datastore
- an extension to the Netconf <copy-config> operation to
allow it to operate on the factory-default datastore.
It provides functionality to reset a YANG datastore to its
factory-default content.
Copyright (c) 2018 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Wu, et al. Expires April 14, 2019 [Page 5]
Internet-Draft Factory Default Setting October 2018
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject to
the license terms contained in, the Simplified BSD License set
forth in Section 4.c of the IETF Trust's Legal Provisions
Relating to IETF Documents
(https://trustee.ietf.org/license-info).
The key words 'MUST', 'MUST NOT', 'REQUIRED', 'SHALL', 'SHALL
NOT', 'SHOULD', 'SHOULD NOT', 'RECOMMENDED', 'MAY', and
'OPTIONAL' in the module text are to be interpreted as described
in RFC 2119 (https://tools.ietf.org/html/rfc2119).
This version of this YANG module is part of RFC XXXX
(https://tools.ietf.org/html/rfcXXXX); see the RFC itself for
full legal notices.";
revision 2018-10-09 {
description
"Initial revision.";
reference "RFC XXXX: Factory default Setting Capability for
RESTCONF";
}
feature factory-default-as-datastore {
description "Indicates that the factory default configuration is
also available as a separate datastore";
}
rpc reset-datastore {
description "The target datastore is reset to its factory
default content. ";
input {
leaf-list target-datasore {
type identityref {
base "ds:datastore" ;
}
min-elements 1;
description "The datastore(s) whose content will be
replaced by the factory-default configuration.";
}
// Do we need an extra parameter that may order a restart of
// the YANG-server or the whole system?
}
}
identity factory-default {
if-feature factory-default-as-datastore;
Wu, et al. Expires April 14, 2019 [Page 6]
Internet-Draft Factory Default Setting October 2018
base ds:datastore;
description "The read-only datastore contains the configuration that
will be copied into e.g. the running datastore by the
reset-datastore operation if the target is the running
datastore.";
}
augment /nc:copy-config/nc:input/nc:source/nc:config-source {
if-feature factory-default-as-datastore;
description " Allows the copy-config operation to use the
factory-default datastore as a source";
leaf factory-default {
type empty ;
description
"The factory-default datastore is the source."; }
}
}
<CODE ENDS>
5. IANA Considerations
This document registers one URI in the IETF XML Registry [RFC3688].
The following registration has been made:
URI: urn:ietf:params:xml:ns:yang:ietf-factory-reset
Registrant Contact: The IESG.
XML: N/A, the requested URI is an XML namespace.
This document registers one YANG module in the YANG Module Names
Registry [RFC6020]. The following registration has been made:
name: ietf-factory-reset
namespace: urn:ietf:params:xml:ns:yang:ietf-factory-reset
prefix: fres
RFC: xxxx
6. Security Considerations
The <reset-datastore> RPC can overwrite important and security
sensitive information in one of the other datastores e.g. running,
therefore it is important to restrict access to this RPC using the
standard NETCONF/RESTCONF access control methods.[RFC8341]
Wu, et al. Expires April 14, 2019 [Page 7]
Internet-Draft Factory Default Setting October 2018
The content of the factory-default datastore is usually not security
sensitive as it is the same on any device of a certain type.
7. Acknowledgements
Thanks to Juergen Schoenwaelder, Ladislav Lhotka to review this draft
and provide important input to this document.
8. Contributors
Rohit R Ranade
Huawei
Email: rohitrranade@huawei.com
9. References
9.1. Normative References
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119,
DOI 10.17487/RFC2119, March 1997,
<https://www.rfc-editor.org/info/rfc2119>.
[RFC6241] Enns, R., Ed., Bjorklund, M., Ed., Schoenwaelder, J., Ed.,
and A. Bierman, Ed., "Network Configuration Protocol
(NETCONF)", RFC 6241, DOI 10.17487/RFC6241, June 2011,
<https://www.rfc-editor.org/info/rfc6241>.
[RFC7950] Bjorklund, M., Ed., "The YANG 1.1 Data Modeling Language",
RFC 7950, DOI 10.17487/RFC7950, August 2016,
<https://www.rfc-editor.org/info/rfc7950>.
[RFC8174] Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC
2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174,
May 2017, <https://www.rfc-editor.org/info/rfc8174>.
[RFC8341] Bierman, A. and M. Bjorklund, "Network Configuration
Access Control Model", STD 91, RFC 8341,
DOI 10.17487/RFC8341, March 2018,
<https://www.rfc-editor.org/info/rfc8341>.
[RFC8342] Bjorklund, M., Schoenwaelder, J., Shafer, P., Watsen, K.,
and R. Wilton, "Network Management Datastore Architecture
(NMDA)", RFC 8342, DOI 10.17487/RFC8342, March 2018,
<https://www.rfc-editor.org/info/rfc8342>.
Wu, et al. Expires April 14, 2019 [Page 8]
Internet-Draft Factory Default Setting October 2018
9.2. Informative References
[I-D.ietf-netconf-zerotouch]
Watsen, K., Abrahamsson, M., and I. Farrer, "Zero Touch
Provisioning for Networking Devices", draft-ietf-netconf-
zerotouch-25 (work in progress), September 2018.
[I-D.lengyel-netmod-yang-instance-data]
Lengyel, B. and B. Claise, "YANG Instance Data Files and
their use for Documenting Server Capabilities", draft-
lengyel-netmod-yang-instance-data-03 (work in progress),
July 2018.
Appendix A. Open Issues
o Do we need a restart after <reset-datastore> ? What kind of
restart, just the Yang-Server or the full system?
o Do we need the concept of reboot? How is that different from a
restart? Does it result in some sort of reset-datastore?
Appendix B. Changes between revisions
v02 - v03
o Restructured
o Made new datastore optional
o Removed Netconf capability
o Listed Open issues
v01 - v02
o -
v00 - v01
o -
Authors' Addresses
Wu, et al. Expires April 14, 2019 [Page 9]
Internet-Draft Factory Default Setting October 2018
Qin Wu
Huawei
101 Software Avenue, Yuhua District
Nanjing, Jiangsu 210012
China
Email: bill.wu@huawei.com
Balazs Lengyel
Ericsson Hungary
Magyar Tudosok korutja 11
1117 Budapest
Hungary
Phone: +36-70-330-7909
Email: balazs.lengyel@ericsson.com
Ye Niu
Huawei
Email: niuye@huawei.com
Wu, et al. Expires April 14, 2019 [Page 10]