rfc3621
Network Working Group A. Berger
Request for Comments: 3621 PowerDsine Inc.
Category: Standards Track D. Romascanu
Avaya
December 2003
Power Ethernet MIB
Status of this Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Copyright Notice
Copyright (C) The Internet Society (2003). All Rights Reserved.
Abstract
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in the Internet community.
This document proposes an extension to the Ethernet-like Interfaces
MIB with a set of objects for managing Power Sourcing Equipment
(PSE).
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 2
2. The Internet-Standard Management Framework . . . . . . . . . . 2
3. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
4. MIB Structure. . . . . . . . . . . . . . . . . . . . . . . . . 3
5. Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . 3
6. Acknowledgements . . . . . . . . . . . . . . . . . . . . . . . 16
7. References . . . . . . . . . . . . . . . . . . . . . . . . . . 16
7.1. Normative References . . . . . . . . . . . . . . . . . . 16
7.2. Informative References . . . . . . . . . . . . . . . . . 17
8. Intellectual Property Statement. . . . . . . . . . . . . . . . 17
9. Security Considerations. . . . . . . . . . . . . . . . . . . . 18
10. Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . 19
11. Full Copyright Statement . . . . . . . . . . . . . . . . . . . 20
Berger & Romascanu Standards Track [Page 1]
RFC 3621 Power Ethernet MIB December 2003
1. Introduction
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in the Internet community.
In particular, it defines a set of MIB objects to manage Power
Ethernet [IEEE-802.3af] Power Sourcing Equipment (PSE).
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in [RFC2119].
2. The Internet-Standard Management Framework
For a detailed overview of the documents that describe the current
Internet-Standard Management Framework, please refer to section 7 of
RFC 3410 [RFC3410].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. MIB objects are generally
accessed through the Simple Network Management Protocol (SNMP).
Objects in the MIB are defined using the mechanisms defined in the
Structure of Management Information (SMI). This memo specifies a MIB
module that is compliant to the SMIv2, which is described in STD 58,
RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
[RFC2580].
3. Overview
The emergence of IP telephony as an application that allows voice
applications to be run over the same infrastructure as data
applications has led to the emergence of Ethernet IP phones, which
have similar functions and characteristics as traditional phones.
Powering the phone with the same cable used for signal transfer is
one of the functions that are being taken as granted. The IEEE 802.3
Working Group has initiated standardization on this subject,
currently known as the IEEE 802.3af work [IEEE-802.3af].
The IEEE 802.3af WG did not define a full management interface, but
only the hardware registers that will allow for management interfaces
to be built for a powered Ethernet device. The MIB module defined in
this document extends the Ethernet-like Interfaces MIB [RFC3635] with
the management objects required for the management of the powered
Ethernet devices and ports.
Berger & Romascanu Standards Track [Page 2]
RFC 3621 Power Ethernet MIB December 2003
The following abbreviations are defined in [IEEE-802.3af] and will be
used with the same significance in this document:
PSE - Power Sourcing Equipment;
PD - Powered Device
4. MIB Structure
These MIB objects are categorized into three MIB groups.
The pethPsePortTable defines the objects used for configuring and
describing the status of ports on a PSE device. Examples of PSE
devices are Ethernet switches that support power Ethernet and mid-
span boxes.
The pethMainPseObjects MIB group defines the management objects for a
managed main power source in a PSE device. Ethernet switches are one
example of boxes that would support these objects.
The pethNotificationControlTable includes objects that control the
transmission of notifications from the agent to a management
application.
5. Definitions
POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, mib-2, OBJECT-TYPE, Integer32,
Gauge32, Counter32, NOTIFICATION-TYPE
FROM SNMPv2-SMI
TruthValue
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB;
powerEthernetMIB MODULE-IDENTITY
LAST-UPDATED "200311240000Z" -- November 24, 2003
ORGANIZATION "IETF Ethernet Interfaces and Hub MIB
Working Group"
Berger & Romascanu Standards Track [Page 3]
RFC 3621 Power Ethernet MIB December 2003
CONTACT-INFO
"
WG Charter:
http://www.ietf.org/html.charters/hubmib-charter.html
Mailing lists:
General Discussion: hubmib@ietf.org
To Subscribe: hubmib-requests@ietf.org
In Body: subscribe your_email_address
Chair: Dan Romascanu
Avaya
Tel: +972-3-645-8414
Email: dromasca@avaya.com
Editor: Avi Berger
PowerDsine Inc.
Tel: 972-9-7755100 Ext 307
Fax: 972-9-7755120
E-mail: avib@PowerDsine.com
"
DESCRIPTION
"The MIB module for managing Power Source Equipment
(PSE) working according to the IEEE 802.af Powered
Ethernet (DTE Power via MDI) standard.
The following terms are used throughout this
MIB module. For complete formal definitions,
the IEEE 802.3 standards should be consulted
wherever possible:
Group - A recommended, but optional, entity
defined by the IEEE 802.3 management standard,
in order to support a modular numbering scheme.
The classical example allows an implementor to
represent field-replaceable units as groups of
ports, with the port numbering matching the
modular hardware implementation.
Port - This entity identifies the port within the group
for which this entry contains information. The numbering
scheme for ports is implementation specific.
Copyright (c) The Internet Society (2003). This version
of this MIB module is part of RFC 3621; See the RFC
itself for full legal notices."
Berger & Romascanu Standards Track [Page 4]
RFC 3621 Power Ethernet MIB December 2003
REVISION "200311240000Z" -- November 24, 2003
DESCRIPTION "Initial version, published as RFC 3621."
::= { mib-2 105 }
pethNotifications OBJECT IDENTIFIER ::= { powerEthernetMIB 0 }
pethObjects OBJECT IDENTIFIER ::= { powerEthernetMIB 1 }
pethConformance OBJECT IDENTIFIER ::= { powerEthernetMIB 2 }
-- PSE Objects
pethPsePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF PethPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of objects that display and control the power
characteristics of power Ethernet ports on a Power Source
Entity (PSE) device. This group will be implemented in
managed power Ethernet switches and mid-span devices.
Values of all read-write objects in this table are
persistent at restart/reboot."
::= { pethObjects 1 }
pethPsePortEntry OBJECT-TYPE
SYNTAX PethPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects that display and control the power
characteristics of a power Ethernet PSE port."
INDEX { pethPsePortGroupIndex , pethPsePortIndex }
::= { pethPsePortTable 1 }
PethPsePortEntry ::= SEQUENCE {
pethPsePortGroupIndex
Integer32,
pethPsePortIndex
Integer32,
pethPsePortAdminEnable
TruthValue,
pethPsePortPowerPairsControlAbility
TruthValue,
pethPsePortPowerPairs
INTEGER,
pethPsePortDetectionStatus
INTEGER,
pethPsePortPowerPriority
INTEGER,
Berger & Romascanu Standards Track [Page 5]
RFC 3621 Power Ethernet MIB December 2003
pethPsePortMPSAbsentCounter
Counter32,
pethPsePortType
SnmpAdminString,
pethPsePortPowerClassifications
INTEGER,
pethPsePortInvalidSignatureCounter
Counter32,
pethPsePortPowerDeniedCounter
Counter32,
pethPsePortOverLoadCounter
Counter32,
pethPsePortShortCounter
Counter32
}
pethPsePortGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is
connected. Group means box in the stack, module in a
rack and the value 1 MUST be used for non-modular devices.
Furthermore, the same value MUST be used in this variable,
pethMainPseGroupIndex, and pethNotificationControlGroupIndex
to refer to a given box in a stack or module in the rack."
::= { pethPsePortEntry 1 }
pethPsePortIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This variable uniquely identifies the power Ethernet PSE
port within group pethPsePortGroupIndex to which the
power Ethernet PSE entry is connected."
::= { pethPsePortEntry 2 }
pethPsePortAdminEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"true (1) An interface which can provide the PSE functions.
false(2) The interface will act as it would if it had no PSE
function."
Berger & Romascanu Standards Track [Page 6]
RFC 3621 Power Ethernet MIB December 2003
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.2 aPSEAdminState"
::= { pethPsePortEntry 3 }
pethPsePortPowerPairsControlAbility OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the capability of controlling the power pairs
functionality to switch pins for sourcing power.
The value true indicate that the device has the capability
to control the power pairs. When false the PSE Pinout
Alternative used cannot be controlled through the
PethPsePortAdminEnable attribute."
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.3
aPSEPowerPairsControlAbility"
::= { pethPsePortEntry 4 }
pethPsePortPowerPairs OBJECT-TYPE
SYNTAX INTEGER {
signal(1),
spare(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes or controls the pairs in use. If the value of
pethPsePortPowerPairsControl is true, this object is
writable.
A value of signal(1) means that the signal pairs
only are in use.
A value of spare(2) means that the spare pairs
only are in use."
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.4 aPSEPowerPairs"
::= { pethPsePortEntry 5 }
pethPsePortDetectionStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
searching(2),
deliveringPower(3),
fault(4),
test(5),
otherFault(6)
}
Berger & Romascanu Standards Track [Page 7]
RFC 3621 Power Ethernet MIB December 2003
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the operational status of the port PD detection.
A value of disabled(1)- indicates that the PSE State diagram
is in the state DISABLED.
A value of deliveringPower(3) - indicates that the PSE State
diagram is in the state POWER_ON for a duration greater than
tlim max (see IEEE Std 802.3af Table 33-5 tlim).
A value of fault(4) - indicates that the PSE State diagram is
in the state TEST_ERROR.
A value of test(5) - indicates that the PSE State diagram is
in the state TEST_MODE.
A value of otherFault(6) - indicates that the PSE State
diagram is in the state IDLE due to the variable
error_conditions.
A value of searching(2)- indicates the PSE State diagram is
in a state other than those listed above."
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.5
aPSEPowerDetectionStatus"
::= { pethPsePortEntry 6 }
pethPsePortPowerPriority OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
high(2),
low(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the priority of the port from the point
of view of a power management algorithm. The priority that
is set by this variable could be used by a control mechanism
that prevents over current situations by disconnecting first
ports with lower power priority. Ports that connect devices
critical to the operation of the network - like the E911
telephones ports - should be set to higher priority."
::= { pethPsePortEntry 7 }
pethPsePortMPSAbsentCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when the PSE state diagram
transitions directly from the state POWER_ON to the
Berger & Romascanu Standards Track [Page 8]
RFC 3621 Power Ethernet MIB December 2003
state IDLE due to tmpdo_timer_done being asserted."
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.11
aPSEMPSAbsentCounter"
::= { pethPsePortEntry 8 }
pethPsePortType OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A manager will set the value of this variable to indicate
the type of powered device that is connected to the port.
The default value supplied by the agent if no value has
ever been set should be a zero-length octet string."
::= { pethPsePortEntry 9 }
pethPsePortPowerClassifications OBJECT-TYPE
SYNTAX INTEGER {
class0(1),
class1(2),
class2(3),
class3(4),
class4(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Classification is a way to tag different terminals on the
Power over LAN network according to their power consumption.
Devices such as IP telephones, WLAN access points and others,
will be classified according to their power requirements.
The meaning of the classification labels is defined in the
IEEE specification.
This variable is valid only while a PD is being powered,
that is, while the attribute pethPsePortDetectionStatus
is reporting the enumeration deliveringPower."
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.6
aPSEPowerClassification"
::= { pethPsePortEntry 10 }
pethPsePortInvalidSignatureCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
Berger & Romascanu Standards Track [Page 9]
RFC 3621 Power Ethernet MIB December 2003
DESCRIPTION
"This counter is incremented when the PSE state diagram
enters the state SIGNATURE_INVALID."
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.7
aPSEInvalidSignatureCounter"
::= { pethPsePortEntry 11 }
pethPsePortPowerDeniedCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when the PSE state diagram
enters the state POWER_DENIED."
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.8
aPSEPowerDeniedCounter"
::= { pethPsePortEntry 12 }
pethPsePortOverLoadCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when the PSE state diagram
enters the state ERROR_DELAY_OVER."
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.9
aPSEOverLoadCounter"
::= { pethPsePortEntry 13 }
pethPsePortShortCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when the PSE state diagram
enters the state ERROR_DELAY_SHORT."
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.10
aPSEShortCounter"
::= { pethPsePortEntry 14 }
-- Main PSE Objects
pethMainPseObjects OBJECT IDENTIFIER ::= { pethObjects 3 }
Berger & Romascanu Standards Track [Page 10]
RFC 3621 Power Ethernet MIB December 2003
pethMainPseTable OBJECT-TYPE
SYNTAX SEQUENCE OF PethMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of objects that display and control attributes
of the main power source in a PSE device. Ethernet
switches are one example of boxes that would support
these objects.
Values of all read-write objects in this table are
persistent at restart/reboot."
::= { pethMainPseObjects 1 }
pethMainPseEntry OBJECT-TYPE
SYNTAX PethMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects that display and control the Main
power of a PSE. "
INDEX { pethMainPseGroupIndex }
::= { pethMainPseTable 1 }
PethMainPseEntry ::= SEQUENCE {
pethMainPseGroupIndex
Integer32,
pethMainPsePower
Gauge32 ,
pethMainPseOperStatus
INTEGER,
pethMainPseConsumptionPower
Gauge32,
pethMainPseUsageThreshold
Integer32
}
pethMainPseGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This variable uniquely identifies the group to which
power Ethernet PSE is connected. Group means (box in
the stack, module in a rack) and the value 1 MUST be
used for non-modular devices. Furthermore, the same
value MUST be used in this variable, pethPsePortGroupIndex,
and pethNotificationControlGroupIndex to refer to a
given box in a stack or module in a rack."
::= { pethMainPseEntry 1 }
Berger & Romascanu Standards Track [Page 11]
RFC 3621 Power Ethernet MIB December 2003
pethMainPsePower OBJECT-TYPE
SYNTAX Gauge32 (1..65535)
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal power of the PSE expressed in Watts."
::= { pethMainPseEntry 2 }
pethMainPseOperStatus OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
faulty(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational status of the main PSE."
::= { pethMainPseEntry 3 }
pethMainPseConsumptionPower OBJECT-TYPE
SYNTAX Gauge32
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured usage power expressed in Watts."
::= { pethMainPseEntry 4 }
pethMainPseUsageThreshold OBJECT-TYPE
SYNTAX Integer32 (1..99)
UNITS "%"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The usage threshold expressed in percents for
comparing the measured power and initiating
an alarm if the threshold is exceeded."
::= { pethMainPseEntry 5 }
-- Notification Control Objects
pethNotificationControl OBJECT IDENTIFIER ::= { pethObjects 4 }
pethNotificationControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF PethNotificationControlEntry
MAX-ACCESS not-accessible
Berger & Romascanu Standards Track [Page 12]
RFC 3621 Power Ethernet MIB December 2003
STATUS current
DESCRIPTION
"A table of objects that display and control the
Notification on a PSE device.
Values of all read-write objects in this table are
persistent at restart/reboot."
::= { pethNotificationControl 1 }
pethNotificationControlEntry OBJECT-TYPE
SYNTAX PethNotificationControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects that control the Notification events."
INDEX { pethNotificationControlGroupIndex }
::= { pethNotificationControlTable 1 }
PethNotificationControlEntry ::= SEQUENCE {
pethNotificationControlGroupIndex
Integer32,
pethNotificationControlEnable
TruthValue
}
pethNotificationControlGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This variable uniquely identifies the group. Group
means box in the stack, module in a rack and the value
1 MUST be used for non-modular devices. Furthermore,
the same value MUST be used in this variable,
pethPsePortGroupIndex, and
pethMainPseGroupIndex to refer to a given box in a
stack or module in a rack. "
::= { pethNotificationControlEntry 1 }
pethNotificationControlEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls, on a per-group basis, whether
or not notifications from the agent are enabled. The
value true(1) means that notifications are enabled; the
value false(2) means that they are not."
::= { pethNotificationControlEntry 2 }
Berger & Romascanu Standards Track [Page 13]
RFC 3621 Power Ethernet MIB December 2003
--
-- Notifications Section
--
--
pethPsePortOnOffNotification NOTIFICATION-TYPE
OBJECTS { pethPsePortDetectionStatus }
STATUS current
DESCRIPTION
" This Notification indicates if Pse Port is delivering or
not power to the PD. This Notification SHOULD be sent on
every status change except in the searching mode.
At least 500 msec must elapse between notifications
being emitted by the same object instance."
::= { pethNotifications 1 }
pethMainPowerUsageOnNotification NOTIFICATION-TYPE
OBJECTS { pethMainPseConsumptionPower }
STATUS current
DESCRIPTION
" This Notification indicate PSE Threshold usage
indication is on, the usage power is above the
threshold. At least 500 msec must elapse between
notifications being emitted by the same object
instance."
::= { pethNotifications 2 }
pethMainPowerUsageOffNotification NOTIFICATION-TYPE
OBJECTS { pethMainPseConsumptionPower }
STATUS current
DESCRIPTION
" This Notification indicates PSE Threshold usage indication
off, the usage power is below the threshold.
At least 500 msec must elapse between notifications being
emitted by the same object instance."
::= { pethNotifications 3 }
--
-- Conformance Section
--
pethCompliances OBJECT IDENTIFIER ::= { pethConformance 1 }
pethGroups OBJECT IDENTIFIER ::= { pethConformance 2 }
pethCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the
Power Ethernet MIB."
Berger & Romascanu Standards Track [Page 14]
RFC 3621 Power Ethernet MIB December 2003
MODULE -- this module
MANDATORY-GROUPS { pethPsePortGroup,
pethPsePortNotificationGroup,
pethNotificationControlGroup
}
GROUP pethMainPseGroup
DESCRIPTION
"The pethMainPseGroup is mandatory for PSE systems
that implement a main power supply."
GROUP pethMainPowerNotificationGroup
DESCRIPTION
"The pethMainPowerNotificationGroup is mandatory for
PSE systems that implement a main power supply."
::= { pethCompliances 1 }
pethPsePortGroup OBJECT-GROUP
OBJECTS {
pethPsePortAdminEnable,
pethPsePortPowerPairsControlAbility,
pethPsePortPowerPairs,
pethPsePortDetectionStatus,
pethPsePortPowerPriority,
pethPsePortMPSAbsentCounter,
pethPsePortInvalidSignatureCounter,
pethPsePortPowerDeniedCounter,
pethPsePortOverLoadCounter,
pethPsePortShortCounter,
pethPsePortType,
pethPsePortPowerClassifications
}
STATUS current
DESCRIPTION
"PSE Port objects."
::= { pethGroups 1 }
pethMainPseGroup OBJECT-GROUP
OBJECTS {
pethMainPsePower,
pethMainPseOperStatus,
pethMainPseConsumptionPower,
pethMainPseUsageThreshold
}
STATUS current
DESCRIPTION
"Main PSE Objects. "
::= { pethGroups 2 }
pethNotificationControlGroup OBJECT-GROUP
Berger & Romascanu Standards Track [Page 15]
RFC 3621 Power Ethernet MIB December 2003
OBJECTS {
pethNotificationControlEnable
}
STATUS current
DESCRIPTION
"Notification Control Objects. "
::= { pethGroups 3 }
pethPsePortNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { pethPsePortOnOffNotification}
STATUS current
DESCRIPTION "Pse Port Notifications."
::= { pethGroups 4 }
pethMainPowerNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { pethMainPowerUsageOnNotification,
pethMainPowerUsageOffNotification}
STATUS current
DESCRIPTION "Main PSE Notifications."
::= { pethGroups 5 }
END
6. Acknowledgements
This document is the product of the Ethernet Interfaces and Hub MIB
WG. The authors would like to recognize the special contributions of
C.M. Heard and David Law.
7. References
7.1. Normative References
[RFC2026] Bradner, S., "The Internet Standards Process -
Revision 3", BCP 9, RFC 2026, October 1996.
[RFC2578] McCloghrie, K., Perkins, D. and J. Schoenwaelder,
"Structure of Management Information Version 2
(SMIv2)", STD 58, RFC 2578, April 1999.
[RFC2579] McCloghrie, K., Perkins, D. and J. Schoenwaelder,
"Textual Conventions for SMIv2", STD 58, RFC 2579,
April 1999.
[RFC2580] McCloghrie, K., Perkins, D. and J. Schoenwaelder,
"Conformance Statements for SMIv2", STD 58, RFC 2580,
April 1999.
Berger & Romascanu Standards Track [Page 16]
RFC 3621 Power Ethernet MIB December 2003
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
[RFC3635] Flick, J., "Definitions of Managed Objects for the
Ethernet-like Interface Types", RFC 3635, September
2003.
[RFC3411] Harrington, D., Presuhn, R. and B. Wijnen, "An
Architecture for Describing Simple Network Management
Protocol (SNMP) Management Frameworks", STD 62, RFC
3411, December 2002.
[IEEE-802.3af] IEEE 802.3 Working Group, "IEEE Std 802.3af-2003 -
Data Terminal Equipment (DTE) Power via Media
Dependent Interface (MDI)", July 2003.
7.2. Informative References
[RFC3410] Case, J., Mundy, R., Partain, D. and B. Stewart,
"Introduction and Applicability Statements for
Internet-Standard Management Framework", RFC 3410,
December 2002.
8. Intellectual Property Statement
The IETF takes no position regarding the validity or scope of any
intellectual property or other rights that might be claimed to
pertain to the implementation or use of the technology described in
this document or the extent to which any license under such rights
might or might not be available; neither does it represent that it
has made any effort to identify any such rights. Information on the
IETF's procedures with respect to rights in standards-track and
standards-related documentation can be found in BCP-11. Copies of
claims of rights made available for publication and any assurances of
licenses to be made available, or the result of an attempt made to
obtain a general license or permission for the use of such
proprietary rights by implementors or users of this specification can
be obtained from the IETF Secretariat.
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights which may cover technology that may be required to practice
this standard. Please address the information to the IETF Executive
Director.
Berger & Romascanu Standards Track [Page 17]
RFC 3621 Power Ethernet MIB December 2003
9. Security Considerations
There are a number of management objects defined in this MIB module
with a MAX-ACCESS clause of read-write. Such objects may be
considered sensitive or vulnerable in some network environments. The
support for SET operations in a non-secure environment without proper
protection can have a negative effect on network operations.
Setting the following object to incorrect values can result in
improper operation of the PSE, including the possibility that the PD
does not receive power from the PSE port:
pethPsePortAdminEnable
pethPsePortPowerPairs
pethPsePortPowerPriority
pethPsePortType
Setting the following objects to incorrect values can result in an
excessive number of traps being sent to network management stations:
pethMainPseUsageThreshold
pethNotificationControlEnable
Some of the readable objects in this MIB module (i.e., objects with a
MAX-ACCESS other than not-accessible) may be considered sensitive or
vulnerable in some network environments. These are:
pethPsePortPowerPairsControlAbility
pethPsePortPowerPriority
pethPsePortPowerClassifications
It is thus important to control even GET and/or NOTIFY access to
these objects and possibly to even encrypt their values when sending
them over the network via SNMP.
SNMP versions prior to SNMPv3 did not include adequate security.
Even if the network itself is secure (for example by using IPSec),
even then, there is no control as to who on the secure network is
allowed to access and GET/SET (read/change/create/delete) the objects
in this MIB module.
It is RECOMMENDED that implementers consider the security features as
provided by the SNMPv3 framework (see [RFC3410], section 8),
including full support for the SNMPv3 cryptographic mechanisms (for
authentication and privacy).
Berger & Romascanu Standards Track [Page 18]
RFC 3621 Power Ethernet MIB December 2003
Further, deployment of SNMP versions prior to SNMPv3 is NOT
RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
enable cryptographic security. It is then a customer/operator
responsibility to ensure that the SNMP entity giving access to an
instance of this MIB module is properly configured to give access to
the objects only to those principals (users) that have legitimate
rights to indeed GET or SET (change/create/delete) them.
10. Authors' Addresses
Avi Berger
PowerDsine Inc.
1, Hanagar St., P.O. Box 7220
Hod Hasharon 45421,
Israel
Phone: +972-9-7755100 Ext 307
Fax: +972-9-7755120
EMail: avib@PowerDsine.com
Dan Romascanu
Avaya
Atidim Technology Park, Bldg. #3
Tel Aviv, 61131
Israel
Phone: +972-3-645-8414
EMail: dromasca@avaya.com
Berger & Romascanu Standards Track [Page 19]
RFC 3621 Power Ethernet MIB December 2003
11. Full Copyright Statement
Copyright (C) The Internet Society (2003). All Rights Reserved.
This document and translations of it may be copied and furnished to
others, and derivative works that comment on or otherwise explain it
or assist in its implementation may be prepared, copied, published
and distributed, in whole or in part, without restriction of any
kind, provided that the above copyright notice and this paragraph are
included on all such copies and derivative works. However, this
document itself may not be modified in any way, such as by removing
the copyright notice or references to the Internet Society or other
Internet organizations, except as needed for the purpose of
developing Internet standards in which case the procedures for
copyrights defined in the Internet Standards process must be
followed, or as required to translate it into languages other than
English.
The limited permissions granted above are perpetual and will not be
revoked by the Internet Society or its successors or assignees.
This document and the information contained herein is provided on an
"AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Acknowledgement
Funding for the RFC Editor function is currently provided by the
Internet Society.
Berger & Romascanu Standards Track [Page 20]
ERRATA