rfc7771









Internet Engineering Task Force (IETF)                     A. Malis, Ed.
Request for Comments: 7771                                  L. Andersson
Updates: 6870                              Huawei Technologies Co., Ltd.
Category: Standards Track                                H. van Helvoort
ISSN: 2070-1721                                           Hai Gaoming BV
                                                                 J. Shin
                                                              SK Telecom
                                                                 L. Wang
                                                            China Mobile
                                                         A. D'Alessandro
                                                          Telecom Italia
                                                            January 2016


 Switching Provider Edge (S-PE) Protection for MPLS and MPLS Transport
           Profile (MPLS-TP) Static Multi-Segment Pseudowires

Abstract

   In MPLS and MPLS Transport Profile (MPLS-TP) environments, statically
   provisioned Single-Segment Pseudowires (SS-PWs) are protected against
   tunnel failure via MPLS-level and MPLS-TP-level tunnel protection.
   With statically provisioned Multi-Segment Pseudowires (MS-PWs), each
   segment of the MS-PW is likewise protected from tunnel failures via
   MPLS-level and MPLS-TP-level tunnel protection.  However, static MS-
   PWs are not protected end-to-end against failure of one of the
   Switching Provider Edge Routers (S-PEs) along the path of the MS-PW.
   This document describes how to achieve this protection via redundant
   MS-PWs by updating the existing procedures in RFC 6870.  It also
   contains an optional approach based on MPLS-TP Linear Protection.

Status of This Memo

   This is an Internet Standards Track document.

   This document is a product of the Internet Engineering Task Force
   (IETF).  It represents the consensus of the IETF community.  It has
   received public review and has been approved for publication by the
   Internet Engineering Steering Group (IESG).  Further information on
   Internet Standards is available in Section 2 of RFC 5741.

   Information about the current status of this document, any errata,
   and how to provide feedback on it may be obtained at
   http://www.rfc-editor.org/info/rfc7771.







Malis, et al.                Standards Track                    [Page 1]

RFC 7771                    MS-PW Protection                January 2016


Copyright Notice

   Copyright (c) 2016 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of
   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.

Table of Contents

   1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . .   2
     1.1.  Requirements Language . . . . . . . . . . . . . . . . . .   3
   2.  Extension to RFC 6870 to Protect Statically Provisioned
       SS-PWs and MS-PWs . . . . . . . . . . . . . . . . . . . . . .   3
   3.  Operational Considerations  . . . . . . . . . . . . . . . . .   5
   4.  Security Considerations . . . . . . . . . . . . . . . . . . .   5
   5.  References  . . . . . . . . . . . . . . . . . . . . . . . . .   5
     5.1.  Normative References  . . . . . . . . . . . . . . . . . .   5
     5.2.  Informative References  . . . . . . . . . . . . . . . . .   6
   Appendix A.  Optional Linear Protection Approach  . . . . . . . .   7
     A.1.  Introduction  . . . . . . . . . . . . . . . . . . . . . .   7
     A.2.  Encapsulation of the PSC Protocol for Pseudowires . . . .   8
   Acknowledgements  . . . . . . . . . . . . . . . . . . . . . . . .   8
   Authors' Addresses  . . . . . . . . . . . . . . . . . . . . . . .   9

1.  Introduction

   In MPLS and MPLS Transport Profile (MPLS-TP) Packet Switched Networks
   (PSNs), pseudowires (PWs) are transported by MPLS(-TP) Label Switched
   Paths (LSPs), also known as tunnels.

   As described in RFC 5659 [RFC5659], Multi-Segment Pseudowires (MS-
   PWs) consist of Terminating Provider Edge Routers PEs (T-PEs), one or
   more Switching Provider Edge Routers (S-PEs), and a sequence of
   tunneled PW segments that connects one of the T-PEs with its
   "adjacent" S-PE, connects this S-PE with the next S-PE in the
   sequence, and so on until the last S-PE is connected by the last PW
   segment to the remaining T-PE.  In MPLS and MPLS-TP environments,
   statically provisioned Single-Segment Pseudowires (SS-PWs) are
   protected against tunnel failure via MPLS-level and MPLS-TP-level
   tunnel protection.  With statically provisioned Multi-Segment



Malis, et al.                Standards Track                    [Page 2]

RFC 7771                    MS-PW Protection                January 2016


   Pseudowires (MS-PWs), each PW segment of the MS-PW is likewise
   protected from tunnel failure via MPLS-level and MPLS-TP-level tunnel
   protection.  However, tunnel protection does not protect static MS-
   PWs from failures of S-PEs along the path of the MS-PW.

   RFC 6718 [RFC6718] provides a general framework for PW protection,
   and RFC 6870 [RFC6870], which is based upon that framework, describes
   protection procedures for MS-PWs that are dynamically signaled using
   LDP.  This document describes how to achieve protection against S-PE
   failure in a static MS-PW by extending RFC 6870 to be applicable for
   statically provisioned MS-PWs pseudowires (PWs) as well.

   This document also contains an OPTIONAL alternative approach based on
   MPLS-TP Linear Protection.  This approach, described in Appendix A,
   MUST be identically provisioned in the PE endpoints for the protected
   MS-PW in order to be used.  See Appendix A for further details on
   this alternative approach.

   This document differs from [PW-REDUNDANCY] in that it provides end-
   to-end resiliency for static MS-PWs, whereas [PW-REDUNDANCY] provides
   resiliency at intermediate S-PEs and resiliency for both dynamically
   signaled and static MS-PWs.

   PWs based on the Layer 2 Tunneling Protocol Version 3 (L2TPv3) are
   outside the scope of this document.

1.1.  Requirements Language

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in RFC 2119 [RFC2119].

2.  Extension to RFC 6870 to Protect Statically Provisioned SS-PWs and
    MS-PWs

   Section 3.2.3 of RFC 6718 and Appendix A.5 of RFC 6870 document how
   to use redundant MS-PWs to protect an MS-PW against S-PE failure in
   the case of a singly homed Customer Edge (CE), using the following
   network model from RFC 6718:












Malis, et al.                Standards Track                    [Page 3]

RFC 7771                    MS-PW Protection                January 2016


       Native   |<----------- Pseudowires ----------->|  Native
       Service  |                                     |  Service
        (AC)    |     |<-PSN1-->|     |<-PSN2-->|     |  (AC)
          |     V     V         V     V         V     V   |
          |     +-----+         +-----+         +-----+   |
   +----+ |     |T-PE1|=========|S-PE1|=========|T-PE2|   |   +----+
   |    |-------|......PW1-Seg1.......|.PW1-Seg2......|-------|    |
   | CE1|       |     |=========|     |=========|     |       | CE2|
   |    |       +-----+         +-----+         +-----+       |    |
   +----+        |.||.|                          |.||.|       +----+
                 |.||.|         +-----+          |.||.|
                 |.||.|=========|     |========== .||.|
                 |.||...PW2-Seg1......|.PW2-Seg2...||.|
                 |.| ===========|S-PE2|============ |.|
                 |.|            +-----+             |.|
                 |.|============+-----+============= .|
                 |.....PW3-Seg1.|     | PW3-Seg2......|
                  ==============|S-PE3|===============
                                |     |
                                +-----+

              Figure 1: Single-Homed CE with Redundant MS-PWs

   In this figure, Customer Edge Router 1 (CE1) is connected to T-PE1,
   and CE2 is connected to T-PE2 via Attachment Circuits (ACs).  There
   are three MS-PWs.  PW1 is switched at S-PE1, PW2 is switched at
   S-PE2, and PW3 is switched at S-PE3.  This scenario provides N:1
   protection against S-PE failure for the subset of the path of the
   emulated service from T-PE1 to T-PE2.

   The procedures in RFCs 6718 and 6870 rely on LDP-based PW status
   signaling to signal the state of the primary MS-PW that is being
   protected, and the precedence in which redundant MS-PW(s) should be
   used to protect the primary MS-PW should it fail.  These procedures
   make use of information carried by the PW Status TLV, which, for
   dynamically signaled PWs, is carried by the LDP.

   However, statically provisioned PWs (SS-PWs or MS-PWs) do not use the
   LDP for PW setup and signaling; rather, they are provisioned by
   network management systems or other means at each T-PE and S-PE along
   their paths.  They also do not use the LDP for status signaling.
   Rather, they use procedures defined in RFC 6478 [RFC6478] for status
   signaling via the PW Operations, Administration, and Maintenance
   (OAM) message using the PW Associated Channel Header (ACH).  The PW
   Status TLV carried via this status signaling is itself identical to
   the PW Status TLV carried via LDP-based status signaling, including
   the identical PW Status Codes.




Malis, et al.                Standards Track                    [Page 4]

RFC 7771                    MS-PW Protection                January 2016


   Sections 6 and 7 of RFC 6870 describe the management of a primary PW
   and its secondary PW(s) to provide resiliency to the failure of the
   primary PW.  They use status codes transmitted between endpoint T-PEs
   using the PW Status TLV transmitted by LDP.  For this management to
   apply to statically provisioned PWs, the PW status signaling defined
   in RFC 6478 MUST be used for the primary and secondary PWs.  In that
   case, the endpoint T-PEs can then use the PW status signaling
   provided by RFC 6478 in place of LDP-based status signaling, so that
   the status-signaling-based procedures in RFC 6870 operate identically
   to when used with LDP-based status signaling.  Note that the optional
   S-PE Bypass Mode defined in Section 5.5 of RFC 6478 cannot be used,
   as it requires LDP signaling.

3.  Operational Considerations

   Because LDP is not used between the T-PEs for statically provisioned
   MS-PWs, the negotiation procedures described in RFC 6870 cannot be
   used.  Thus, operational care must be taken so that the endpoint
   T-PEs are identically provisioned regarding the use of this document,
   specifically whether or not MS-PW redundancy is being used, and for
   each protected MS-PW, the identity of the primary MS-PW and the
   precedence of the secondary MS-PWs.

4.  Security Considerations

   The security considerations defined for RFC 6478 apply to this
   document as well.  As the security considerations in RFCs 6718 and
   6870 are related to their use of LDP, they are not required for this
   document.

   If the alternative approach in Appendix A is used, then the security
   considerations defined for RFCs 6378, 7271, and 7324 also apply.

5.  References

5.1.  Normative References

   [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
              Requirement Levels", BCP 14, RFC 2119,
              DOI 10.17487/RFC2119, March 1997,
              <http://www.rfc-editor.org/info/rfc2119>.

   [RFC6378]  Weingarten, Y., Ed., Bryant, S., Osborne, E., Sprecher,
              N., and A. Fulignoli, Ed., "MPLS Transport Profile (MPLS-
              TP) Linear Protection", RFC 6378, DOI 10.17487/RFC6378,
              October 2011, <http://www.rfc-editor.org/info/rfc6378>.





Malis, et al.                Standards Track                    [Page 5]

RFC 7771                    MS-PW Protection                January 2016


   [RFC6478]  Martini, L., Swallow, G., Heron, G., and M. Bocci,
              "Pseudowire Status for Static Pseudowires", RFC 6478,
              DOI 10.17487/RFC6478, May 2012,
              <http://www.rfc-editor.org/info/rfc6478>.

   [RFC6870]  Muley, P., Ed. and M. Aissaoui, Ed., "Pseudowire
              Preferential Forwarding Status Bit", RFC 6870,
              DOI 10.17487/RFC6870, February 2013,
              <http://www.rfc-editor.org/info/rfc6870>.

   [RFC7271]  Ryoo, J., Ed., Gray, E., Ed., van Helvoort, H.,
              D'Alessandro, A., Cheung, T., and E. Osborne, "MPLS
              Transport Profile (MPLS-TP) Linear Protection to Match the
              Operational Expectations of Synchronous Digital Hierarchy,
              Optical Transport Network, and Ethernet Transport Network
              Operators", RFC 7271, DOI 10.17487/RFC7271, June 2014,
              <http://www.rfc-editor.org/info/rfc7271>.

   [RFC7324]  Osborne, E., "Updates to MPLS Transport Profile Linear
              Protection", RFC 7324, DOI 10.17487/RFC7324, July 2014,
              <http://www.rfc-editor.org/info/rfc7324>.

5.2.  Informative References

   [PW-REDUNDANCY]
              Dong, J. and H. Wang, "Pseudowire Redundancy on S-PE",
              Work in Progress, draft-ietf-pals-redundancy-spe-02,
              August 2015.

   [RFC5659]  Bocci, M. and S. Bryant, "An Architecture for Multi-
              Segment Pseudowire Emulation Edge-to-Edge", RFC 5659,
              DOI 10.17487/RFC5659, October 2009,
              <http://www.rfc-editor.org/info/rfc5659>.

   [RFC6718]  Muley, P., Aissaoui, M., and M. Bocci, "Pseudowire
              Redundancy", RFC 6718, DOI 10.17487/RFC6718, August 2012,
              <http://www.rfc-editor.org/info/rfc6718>.














Malis, et al.                Standards Track                    [Page 6]

RFC 7771                    MS-PW Protection                January 2016


Appendix A.  Optional Linear Protection Approach

A.1.  Introduction

   In "MPLS Transport Profile (MPLS-TP) Linear Protection" [RFC6378], as
   well as in the later updates of that RFC "MPLS Transport Profile
   (MPLS-TP) Linear Protection to Match the Operational Expectations of
   Synchronous Digital Hierarchy, Optical Transport Network, and
   Ethernet Transport Network Operators" [RFC7271] and "Updates to MPLS
   Transport Profile Linear Protection" [RFC7324], the Protection State
   Coordination (PSC) protocol was defined for MPLS LSPs only.

   This appendix extends these RFCs to be applicable for PWs (SS-PW and
   MS-PW) as well.  This is useful especially in the case of end-to-end
   static provisioned MS-PWs running over MPLS-TP where tunnel
   protection alone cannot be relied upon for end-to-end protection of
   PWs against S-PE failure.  It also enables a uniform operational
   approach for protection at LSP and PW layers and an easier management
   integration for networks that already implement the approach in RFCs
   6378, 7271, and 7324.

   The protection architectures are those defined in [RFC6378].  For the
   purposes of this appendix, we define the protection domain of a
   point-to-point PW as consisting of two terminating PEs (T-PEs) and
   the transport paths that connect them (see Figure 2).

                 +-----+ //=======================\\ +-----+
                 |T-PE1|//     Working Path        \\|T-PE2|
                 |    /|                             |\    |
                 |  ?< |                             | >?  |
                 |    \|                             |/    |
                 |     |\\    Protection Path      //|     |
                 +-----+ \\=======================// +-----+

                     |<-------Protection Domain------->|

                        Figure 2: Protection Domain

   This Appendix is an OPTIONAL alternative approach to the one in
   Section 2.  For interoperability, all implementations MUST include
   the approach in Section 2, even if this alternative approach is used.
   The operational considerations in Section 3 continue to apply when
   this approach is used, and operational care must be taken so that the
   endpoint T-PEs are identically provisioned regarding the use of this
   document.






Malis, et al.                Standards Track                    [Page 7]

RFC 7771                    MS-PW Protection                January 2016


A.2.  Encapsulation of the PSC Protocol for Pseudowires

   The PSC protocol can be used to protect against defects on any LSP
   (segment, link, or path).  In the case of MS-PW, the PSC protocol can
   also protect failed intermediate nodes (S-PE).  Linear protection
   protects an LSP or PW end-to-end and if a failure is detected,
   switches traffic over to another (redundant) set of resources.

   Obviously, the protected entity does not need to be of the same type
   as the protecting entity.  For example, it is possible to protect a
   link by a path.  Likewise, it is possible to protect an SS-PW with an
   MS-PW, and vice versa.

   From a PSC protocol point of view, it is possible to view an SS-PW as
   a single-hop LSP and an MS-PW as a multiple-hop LSP.  Thus, this
   provides end-to-end protection for the SS-PW or MS-PW.  The Generic
   Associated Channel (G-Ach) carrying the PSC protocol information is
   placed in the label stack directly beneath the PW identifier.  The
   PSC protocol will then work as specified in RFCs 6378, 7271, and
   7324.

Acknowledgements

   The authors would like to thank Matthew Bocci, Yaakov Stein, David
   Sinicrope, Sasha Vainshtein, and Italo Busi for their comments on
   this document.

   Figure 1 and the explanatory paragraph following the figure were
   taken from RFC 6718.  Figure 2 was adapted from RFC 6378.






















Malis, et al.                Standards Track                    [Page 8]

RFC 7771                    MS-PW Protection                January 2016


Authors' Addresses

   Andrew G. Malis (editor)
   Huawei Technologies Co., Ltd.

   Email: agmalis@gmail.com


   Loa Andersson
   Huawei Technologies Co., Ltd.

   Email: loa@mail01.huawei.com


   Huub van Helvoort
   Hai Gaoming BV

   Email: huubatwork@gmail.com


   Jongyoon Shin
   SK Telecom

   Email: jongyoon.shin@sk.com


   Lei Wang
   China Mobile

   Email: wangleiyj@chinamobile.com


   Alessandro D'Alessandro
   Telecom Italia

   Email: alessandro.dalessandro@telecomitalia.it















Malis, et al.                Standards Track                    [Page 9]



ERRATA