rfc9354







Internet Engineering Task Force (IETF)                            J. Hou
Request for Comments: 9354                                        B. Liu
Category: Standards Track                            Huawei Technologies
ISSN: 2070-1721                                                Y-G. Hong
                                                      Daejeon University
                                                                 X. Tang
                                                                  SGEPRI
                                                              C. Perkins
                                                             Lupin Lodge
                                                            January 2023


    Transmission of IPv6 Packets over Power Line Communication (PLC)
                                Networks

Abstract

   Power Line Communication (PLC), namely using electric power lines for
   indoor and outdoor communications, has been widely applied to support
   Advanced Metering Infrastructure (AMI), especially smart meters for
   electricity.  The existing electricity infrastructure facilitates the
   expansion of PLC deployments due to its potential advantages in terms
   of cost and convenience.  Moreover, a wide variety of accessible
   devices raises the potential demand of IPv6 for future applications.
   This document describes how IPv6 packets are transported over
   constrained PLC networks, such as those described in ITU-T G.9903,
   IEEE 1901.1, and IEEE 1901.2.

Status of This Memo

   This is an Internet Standards Track document.

   This document is a product of the Internet Engineering Task Force
   (IETF).  It represents the consensus of the IETF community.  It has
   received public review and has been approved for publication by the
   Internet Engineering Steering Group (IESG).  Further information on
   Internet Standards is available in Section 2 of RFC 7841.

   Information about the current status of this document, any errata,
   and how to provide feedback on it may be obtained at
   https://www.rfc-editor.org/info/rfc9354.

Copyright Notice

   Copyright (c) 2023 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (https://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Revised BSD License text as described in Section 4.e of the
   Trust Legal Provisions and are provided without warranty as described
   in the Revised BSD License.

Table of Contents

   1.  Introduction
   2.  Requirements Notation and Terminology
   3.  Overview of PLC
     3.1.  Protocol Stack
     3.2.  Addressing Modes
     3.3.  Maximum Transmission Unit
     3.4.  Routing Protocol
   4.  IPv6 over PLC
     4.1.  Stateless Address Autoconfiguration
     4.2.  IPv6 Link-Local Address
     4.3.  Unicast Address Mapping
       4.3.1.  Unicast Address Mapping for IEEE 1901.1
       4.3.2.  Unicast Address Mapping for IEEE 1901.2 and ITU-T
               G.9903
     4.4.  Neighbor Discovery
     4.5.  Header Compression
     4.6.  Fragmentation and Reassembly
   5.  Internet Connectivity Scenarios and Topologies
   6.  Operations and Manageability Considerations
   7.  IANA Considerations
   8.  Security Considerations
   9.  References
     9.1.  Normative References
     9.2.  Informative References
   Acknowledgements
   Authors' Addresses

1.  Introduction

   The idea of using power lines for both electricity supply and
   communication can be traced back to the beginning of the last
   century.  Using the existing power grid to transmit messages, Power
   Line Communication (PLC) is a good candidate for supporting various
   service scenarios such as in houses and offices, in trains and
   vehicles, in smart grids, and in Advanced Metering Infrastructure
   (AMI) [SCENA].  The data-acquisition devices in these scenarios share
   common features such as fixed position, large quantity of nodes, low
   data rate, and low power consumption.

   Although PLC technology has evolved over several decades, it has not
   been fully adapted for IPv6-based constrained networks.  The
   resource-constrained scenarios related to the Internet of Things
   (IoT) lie in the low voltage PLC networks with most applications in
   the area of AMI, vehicle-to-grid communications, in-home energy
   management, and smart street lighting.  IPv6 is important for PLC
   networks, due to its large address space and efficient address
   autoconfiguration.

   This document provides a brief overview of PLC technologies.  Some of
   them have LLN (Low-Power and Lossy Network) characteristics, i.e.,
   limited power consumption, memory, and processing resources.  This
   document specifies the transmission of IPv6 packets over those
   constrained PLC networks.  The general approach is to adapt elements
   of the 6LoWPAN (IPv6 over Low-Power Wireless Personal Area Network)
   and 6lo (IPv6 over Networks of Resource-constrained Nodes)
   specifications, such as those described in [RFC4944], [RFC6282],
   [RFC6775], and [RFC8505], to constrained PLC networks.

2.  Requirements Notation and Terminology

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
   "OPTIONAL" in this document are to be interpreted as described in
   BCP 14 [RFC2119] [RFC8174] when, and only when, they appear in all
   capitals, as shown here.

   This document uses the following acronyms and terminologies:

   6BBR:  6LoWPAN Backbone Router

   6LBR:  6LoWPAN Border Router

   6lo:  IPv6 over Networks of Resource-constrained Nodes

   6LoWPAN:  IPv6 over Low-Power Wireless Personal Area Network

   6LR:  6LoWPAN Router

   AMI:  Advanced Metering Infrastructure

   BBPLC:  Broadband Power Line Communication

   Coordinator:  A device capable of relaying messages

   DAD:  Duplicate Address Detection

   EUI:  Extended Unique Identifier

   IID:  Interface Identifier

   LLN:  Low-Power and Lossy Network

   MTU:  Maximum Transmission Unit

   NBPLC:  Narrowband Power Line Communication

   PAN:  Personal Area Network

   PANC:  PAN Coordinator, a coordinator that also acts as the primary
      controller of a PAN

   PLC:  Power Line Communication

   PLC device:  An entity that follows the PLC standards and implements
      the protocol stack described in this document

   RA:  Router Advertisement

   RPL:  Routing Protocol for Low-Power and Lossy Networks

   Below is a mapping table of the terminology between [IEEE_1901.2],
   [IEEE_1901.1], [ITU-T_G.9903], and this document.

     +=================+=============+===============+===============+
     |   IEEE 1901.2   | IEEE 1901.1 |  ITU-T G.9903 | This document |
     +=================+=============+===============+===============+
     | PAN Coordinator |   Central   |      PAN      |      PAN      |
     |                 | Coordinator |  Coordinator  |  Coordinator  |
     +-----------------+-------------+---------------+---------------+
     |   Coordinator   |    Proxy    | Full-Function |  Coordinator  |
     |                 | Coordinator |     Device    |               |
     +-----------------+-------------+---------------+---------------+
     |      Device     |   Station   |   PAN Device  |   PLC Device  |
     +-----------------+-------------+---------------+---------------+

             Table 1: Terminology Mapping between PLC Standards

3.  Overview of PLC

   PLC technology enables convenient two-way communications for home
   users and utility companies to monitor and control electrically
   connected devices such as electricity meters and street lights.  PLC
   can also be used in smart home scenarios, such as the control of
   indoor lights and switches.  Due to the large range of communication
   frequencies, PLC is generally classified into two categories:
   Narrowband PLC (NBPLC) for automation of sensors (which have a low
   frequency band and low power cost) and Broadband PLC (BBPLC) for home
   and industry networking applications.

   Various standards have been addressed on the Media Access Control
   (MAC) and Physical (PHY) layers.  For example, standards for BBPLC
   (1.8-250 MHz) include IEEE 1901 and ITU-T G.hn, and standards for
   NBPLC (3-500 kHz) include ITU-T G.9902 (G.hnem), ITU-T G.9903
   (G3-PLC) [ITU-T_G.9903], ITU-T G.9904 (PRIME), IEEE 1901.2 (a
   combination of G3-PLC and PRIME PLC) [IEEE_1901.2], and IEEE 1901.2a
   (an amendment to IEEE 1901.2) [IEEE_1901.2a].

   IEEE 1901.1 [IEEE_1901.1], a PLC standard that is aimed at the medium
   frequency band of less than 12 MHz, was published by the IEEE
   standard for Smart Grid Powerline Communication Working Group (SGPLC
   WG).  IEEE 1901.1 balances the needs for bandwidth versus
   communication range and is thus a promising option for 6lo
   applications.

   This specification is focused on IEEE 1901.1, IEEE 1901.2, and ITU-T
   G.9903.

3.1.  Protocol Stack

   The protocol stack for IPv6 over PLC is illustrated in Figure 1.  The
   PLC MAC and PLC PHY layers correspond to the layers described in IEEE
   1901.1, IEEE 1901.2, or ITU-T G.9903.  The 6lo adaptation layer for
   PLC is illustrated in Section 4.  For multihop tree and mesh
   topologies, a routing protocol is likely to be necessary.  The routes
   can be built in mesh-under mode at Layer 2 or in route-over mode at
   Layer 3, as explained in Sections 3.4 and 4.4.

                    +----------------------------------------+
                    |           Application Layer            |
                    +----------------------------------------+
                    |            Transport Layer             |
                    +----------------------------------------+
                    |                                        |
                    |               IPv6 Layer               |
                    |                                        |
                    +----------------------------------------+
                    |   Adaptation Layer for IPv6 over PLC   |
                    +----------------------------------------+
                    |             PLC MAC Layer              |
                    +----------------------------------------+
                    |             PLC PHY Layer              |
                    +----------------------------------------+

                        Figure 1: PLC Protocol Stack

3.2.  Addressing Modes

   Each PLC device has a globally unique long address of 48 bits
   [IEEE_1901.1] or 64 bits [IEEE_1901.2] [ITU-T_G.9903] and a short
   address of 12 bits [IEEE_1901.1] or 16 bits [IEEE_1901.2]
   [ITU-T_G.9903].  The long address is set by the manufacturer
   according to the IEEE EUI-48 MAC address or the IEEE EUI-64 address.
   Each PLC device joins the network by using the long address and
   communicates with other devices by using the short address after
   joining the network.  Short addresses can be assigned during the
   onboarding process, by the PANC or the JRC (join registrar/
   coordinator) in CoJP (Constrained Join Protocol) [RFC9031].

3.3.  Maximum Transmission Unit

   The Maximum Transmission Unit (MTU) of the MAC layer determines
   whether fragmentation and reassembly are needed at the adaptation
   layer of IPv6 over PLC.  IPv6 requires an MTU of 1280 octets or
   greater; thus, for a MAC layer with an MTU lower than this limit,
   fragmentation and reassembly at the adaptation layer are required.

   The IEEE 1901.1 MAC supports upper-layer packets up to 2031 octets.
   The IEEE 1901.2 MAC layer supports an MTU of 1576 octets (the
   original value of 1280 bytes was updated in 2015 [IEEE_1901.2a]).
   Though these two technologies can support IPv6 originally without
   fragmentation and reassembly, it is possible to configure a smaller
   MTU in a high-noise communication environment.  Thus, the 6lo
   functions, including header compression, fragmentation, and
   reassembly, are still applicable and useful.

   The MTU for ITU-T G.9903 is 400 octets, which is insufficient for
   supporting IPv6's MTU.  For this reason, fragmentation and reassembly
   are required for G.9903-based networks to carry IPv6.

3.4.  Routing Protocol

   Routing protocols suitable for use in PLC networks include:

   *  RPL (Routing Protocol for Low-Power and Lossy Networks) [RFC6550]
      is a Layer 3 routing protocol.  AODV-RPL [AODV-RPL] updates RPL to
      include reactive, point-to-point, and asymmetric routing.  IEEE
      1901.2 specifies Information Elements (IEs) with MAC layer
      metrics, which can be provided to a Layer 3 routing protocol for
      parent selection.

   *  IEEE 1901.1 supports the mesh-under routing scheme.  Each PLC node
      maintains a routing table, in which each route entry comprises the
      short addresses of the destination and the related next hop.  The
      route entries are built during the network establishment via a
      pair of association request/confirmation messages.  The route
      entries can be changed via a pair of proxy change request/
      confirmation messages.  These association and proxy change
      messages must be approved by the central coordinator (PANC in this
      document).

   *  LOADng (Lightweight On-demand Ad hoc Distance vector routing
      protocol, Next Generation) is a reactive protocol operating at
      Layer 2 or Layer 3.  Currently, LOADng is supported in ITU-T
      G.9903 [ITU-T_G.9903], and the IEEE 1901.2 standard refers to
      ITU-T G.9903 for LOAD-based networks.

4.  IPv6 over PLC

   A PLC node distinguishes between an IPv6 PDU and a non-IPv6 PDU based
   on the equivalent of an Ethertype in a Layer 2 PLC PDU.  [RFC7973]
   defines an Ethertype of "A0ED" for LoWPAN encapsulation, and this
   information can be carried in the IE field in the MAC header of
   [IEEE_1901.2] or [ITU-T_G.9903].  And regarding [IEEE_1901.1], the IP
   packet type has been defined with the corresponding MAC Service Data
   Unit (MSDU) type value 49.  And the 4-bit Internet Protocol version
   number in the IP header helps to distinguish between an IPv4 PDU and
   an IPv6 PDU.

   6LoWPAN and 6lo standards, as described in [RFC4944], [RFC6282],
   [RFC6775], and [RFC8505], provide useful functionality, including
   link-local IPv6 addresses, stateless address autoconfiguration,
   neighbor discovery, header compression, fragmentation, and
   reassembly.  However, due to the different characteristics of the PLC
   media, the 6LoWPAN adaptation layer, as it is, cannot perfectly
   fulfill the requirements of PLC environments.  These considerations
   suggest the need for a dedicated adaptation layer for PLC, which is
   detailed in the following subsections.

4.1.  Stateless Address Autoconfiguration

   To obtain an IPv6 Interface Identifier (IID), a PLC device performs
   stateless address autoconfiguration [RFC4944].  The autoconfiguration
   can be based on either a long or short link-layer address.

   The IID can be based on the device's 48-bit MAC address or its EUI-64
   identifier [EUI-64].  A 48-bit MAC address MUST first be extended to
   a 64-bit IID by inserting 0xFFFE at the fourth and fifth octets as
   specified in [RFC2464].  The IPv6 IID is derived from the 64-bit IID
   by inverting the U/L (Universal/Local) bit [RFC4291].

   For IEEE 1901.2 and ITU-T G.9903, a 48-bit "pseudo-address" is formed
   by the 16-bit PAN ID, 16 zero bits, and the 16-bit short address as
   follows:

      16_bit_PAN:0000:16_bit_short_address

   Then, the 64-bit IID MUST be derived by inserting the 16-bit 0xFFFE
   into as follows:

      16_bit_PAN:00FF:FE00:16_bit_short_address

   For the 12-bit short addresses used by IEEE 1901.1, the 48-bit
   pseudo-address is formed by a 24-bit NID (Network Identifier,
   YYYYYY), 12 zero bits, and a 12-bit TEI (Terminal Equipment
   Identifier, XXX) as follows:

      YYYY:YY00:0XXX

   The 64-bit IID MUST be derived by inserting the 16-bit 0xFFFE into
   this 48-bit pseudo-address as follows:

      YYYY:YYFF:FE00:0XXX

   As investigated in [RFC7136], aside from the method discussed in
   [RFC4291], other IID-generation methods defined by the IETF do not
   imply any additional semantics for the Universal/Local (U/L) bit (bit
   6) and the Individual/Group bit (bit 7).  Therefore, these two bits
   are not reliable indicators.  Thus, when using an IID derived by a
   short address, the operators of the PLC network can choose whether or
   not to comply with the original meaning of these two bits.  If they
   choose to comply with the original meaning, these two bits MUST both
   be set to zero, since the IID derived from the short address is not
   global.  In order to avoid any ambiguity in the derived IID, these
   two bits MUST NOT be a valid part of the PAN ID (for IEEE 1901.2 and
   ITU-T G.9903) or NID (for IEEE 1901.1).  For example, the PAN ID or
   NID must always be chosen so that the two bits are zeros or the high
   six bits in PAN ID or NID are left shifted by two bits.  If they
   choose not to comply with the original meaning, the operator must be
   aware that these two bits are not reliable indicators, and the IID
   cannot be transformed back into a short link-layer address via a
   reverse operation of the mechanism presented above.  However, the
   short address can still be obtained via the Unicast Address Mapping
   mechanism described in Section 4.3.

   For privacy reasons, the IID derived from the MAC address (with
   padding and bit clamping) SHOULD only be used for link-local address
   configuration.  A PLC host SHOULD use the IID derived from the short
   link-layer address to configure IPv6 addresses used for communication
   with the public network; otherwise, the host's MAC address is
   exposed.  As per [RFC8065], when short addresses are used on PLC
   links, a shared secret key or version number from the Authoritative
   Border Router Option [RFC6775] can be used to improve the entropy of
   the hash input.  Thus, the generated IID can be spread out to the
   full range of the IID address space while stateless address
   compression is still allowed.  By default, the hash algorithm SHOULD
   be SHA256, using the version number, the PAN ID or NID, and the short
   address as the input arguments, and the 256-bit hash output is
   truncated into the IID by taking the high 64 bits.

4.2.  IPv6 Link-Local Address

   The IPv6 link-local address [RFC4291] for a PLC interface is formed
   by appending the IID, as defined above, to the prefix FE80::/64 (see
   Figure 2).

       10 bits           54 bits                   64 bits
     +----------+-----------------------+----------------------------+
     |1111111010|        (zeros)        |    Interface Identifier    |
     +----------+-----------------------+----------------------------+

           Figure 2: IPv6 Link-Local Address for a PLC Interface

4.3.  Unicast Address Mapping

   The address-resolution procedure for mapping IPv6 unicast addresses
   into PLC link-layer addresses follows the general description in
   Section 7.2 of [RFC4861].  [RFC6775] improves this procedure by
   eliminating usage of multicast NS (Neighbor Solicitation).  The
   resolution is realized by the NCEs (neighbor cache entries) created
   during the address registration at the routers.  [RFC8505] further
   improves the registration procedure by enabling multiple LLNs to form
   an IPv6 subnet and by inserting a link-local address registration to
   better serve proxy registration of new devices.

4.3.1.  Unicast Address Mapping for IEEE 1901.1

   The Source Link-Layer Address and Target Link-Layer Address options
   for IEEE_1901.1 used in the NS and Neighbor Advertisement (NA) have
   the following form.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |     Type      |    Length=1   |              NID              :
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    :NID (continued)|  Padding (all zeros)  |          TEI          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

             Figure 3: Unicast Address Mapping for IEEE 1901.1

   Option fields:

   Type:  1 for Source Link-Layer Address and 2 for Target Link-Layer
      Address.

   Length:  The length of this option (including Type and Length fields)
      in units of 8 octets.  The value of this field is 1 for the 12-bit
      IEEE 1901.1 PLC short addresses.

   NID:  24-bit Network Identifier

   Padding:  12 zero bits

   TEI:  12-bit Terminal Equipment Identifier

4.3.2.  Unicast Address Mapping for IEEE 1901.2 and ITU-T G.9903

   The Source Link-Layer Address and Target Link-Layer Address options
   for IEEE_1901.2 and ITU-T G.9903 used in the NS and NA have the
   following form.

      0                   1                   2                   3
      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
     |     Type      |    Length=1   |             PAN ID            |
     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
     |       Padding (all zeros)     |         Short Address         |
     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

             Figure 4: Unicast Address Mapping for IEEE 1901.2

   Option fields:

   Type:  1 for Source Link-Layer Address and 2 for Target Link-Layer
      Address.

   Length:  The length of this option (including Type and Length fields)
      in units of 8 octets.  The value of this field is 1 for the 16-bit
      IEEE 1901.2 PLC short addresses.

   PAN ID:  16-bit PAN IDentifier

   Padding:  16 zero bits

   Short Address:  16-bit short address

4.4.  Neighbor Discovery

   Neighbor discovery procedures for 6LoWPAN networks are described in
   [RFC6775] and [RFC8505].  These optimizations support the
   registration of sleeping hosts.  Although PLC devices are
   electrically powered, sleeping mode SHOULD still be used for power
   saving.

   For IPv6 prefix dissemination, Router Solicitations (RSs) and Router
   Advertisements (RAs) MAY be used as per [RFC6775].  If the PLC
   network uses route-over mode, the IPv6 prefix MAY be disseminated by
   the Layer 3 routing protocol, such as RPL, which may include the
   prefix in the DIO (DODAG Information Object) message.  As per
   [RFC9010], it is possible to have PLC devices configured as RPL-
   unaware leaves, which do not participate in RPL at all, along with
   RPL-aware PLC devices.  In this case, the prefix dissemination SHOULD
   use the RS/RA messages.

   For dissemination of context information, RAs MUST be used as per
   [RFC6775].  The 6LoWPAN context option (6CO) MUST be included in the
   RA to disseminate the Context IDs used for prefix and/or address
   compression.

   For address registration in route-over mode, a PLC device MUST
   register its addresses by sending a unicast link-local NS to the 6LR.
   If the registered address is link local, the 6LR SHOULD NOT further
   register it to the registrar (6LBR or 6BBR).  Otherwise, the address
   MUST be registered via an ARO (Address Registration Option) or EARO
   (Extended Address Registration Option) included in the DAR (Duplicate
   Address Request) [RFC6775] or EDAR (Extended Duplicate Address
   Request) [RFC8505] messages.  For PLC devices compliant with
   [RFC8505], the 'R' flag in the EARO MUST be set when sending NSs in
   order to extract the status information in the replied NAs from the
   6LR.  If DHCPv6 is used to assign addresses or the IPv6 address is
   derived from the unique long or short link-layer address, Duplicate
   Address Detection (DAD) SHOULD NOT be utilized.  Otherwise, DAD MUST
   be performed at the 6LBR (as per [RFC6775]) or proxied by the routing
   registrar (as per [RFC8505]).  The registration status is fed back
   via the DAC (Duplicate Address Confirmation) or EDAC (Extended
   Duplicate Address Confirmation) message from the 6LBR and the NA from
   the 6LR.  Section 6 of [RFC8505] shows how devices that only behave
   as specified in [RFC6775] can work with devices that have been
   updated per [RFC8505].

   For address registration in mesh-under mode, since all the PLC
   devices are link-local neighbors to the 6LBR, DAR/DAC or EDAR/EDAC
   messages are not required.  A PLC device MUST register its addresses
   by sending a unicast NS message with an ARO or EARO.  The
   registration status is fed back via the NA message from the 6LBR.

4.5.  Header Compression

   IPv6 header compression in PLC is based on [RFC6282] (which updates
   [RFC4944]).  [RFC6282] specifies the compression format for IPv6
   datagrams on top of IEEE 802.15.4; therefore, this format is used for
   compression of IPv6 datagrams within PLC MAC frames.  For situations
   when the PLC MAC MTU cannot support the 1280-octet IPv6 packet, the
   headers MUST be compressed according to the encoding formats
   specified in [RFC6282], including the Dispatch Header, the
   LOWPAN_IPHC, and the compression residue carried inline.

   For IEEE 1901.2 and ITU-T G.9903, the IP header compression follows
   the instruction in [RFC6282].  However, additional adaptation MUST be
   considered for IEEE 1901.1 since it has a short address of 12 bits
   instead of 16 bits.  The only modification is the semantics of the
   "Source Address Mode" and the "Destination Address Mode" when set as
   "10" in Section 3.1 of [RFC6282], which is illustrated as follows.

   SAM: Source Address Mode:

   If SAC=0: Stateless compression

   10:   16 bits.  The first 112 bits of the address are elided.  The
         value of the first 64 bits is the link-local prefix padded with
         zeros.  The following 64 bits are 0000:00ff:fe00:0XXX, where
         0XXX are the 16 bits carried inline, in which the first 4 bits
         are zero.

   If SAC=1: Stateful context-based compression

   10:   16 bits.  The address is derived using context information and
         the 16 bits carried inline.  Bits covered by context
         information are always used.  Any IID bits not covered by
         context information are taken directly from their corresponding
         bits in the mapping between the 16-bit short address and the
         IID as provided by 0000:00ff:fe00:0XXX, where 0XXX are the 16
         bits carried inline, in which the first 4 bits are zero.  Any
         remaining bits are zero.

   DAM: Destination Address Mode:

   If M=0 and DAC=0: Stateless compression

   10:   16 bits.  The first 112 bits of the address are elided.  The
         value of the first 64 bits is the link-local prefix padded with
         zeros.  The following 64 bits are 0000:00ff:fe00:0XXX, where
         0XXX are the 16 bits carried inline, in which the first 4 bits
         are zero.

   If M=0 and DAC=1: Stateful context-based compression

   10:   16 bits.  The address is derived using context information and
         the 16 bits carried inline.  Bits covered by context
         information are always used.  Any IID bits not covered by
         context information are taken directly from their corresponding
         bits in the mapping between the 16-bit short address and the
         IID as provided by 0000:00ff:fe00:0XXX, where 0XXX are the 16
         bits carried inline, in which the first 4 bits are zero.  Any
         remaining bits are zero.

4.6.  Fragmentation and Reassembly

   The constrained PLC MAC layer provides the functions of fragmentation
   and reassembly.  However, fragmentation and reassembly are still
   required at the adaptation layer if the MAC layer cannot support the
   minimum MTU demanded by IPv6, which is 1280 octets.

   In IEEE 1901.1 and IEEE 1901.2, the MAC layer supports payloads as
   big as 2031 octets and 1576 octets, respectively.  However, when the
   channel condition is noisy, smaller packets have a higher
   transmission success rate, and the operator can choose to configure
   smaller MTU at the MAC layer.  If the configured MTU is smaller than
   1280 octets, the fragmentation and reassembly defined in [RFC4944]
   MUST be used.

   In ITU-T G.9903, the maximum MAC payload size is fixed to 400 octets,
   so to cope with the required MTU of 1280 octets by IPv6,
   fragmentation and reassembly at the 6lo adaptation layer MUST be
   provided as specified in [RFC4944].

   [RFC4944] uses a 16-bit datagram tag to identify the fragments of the
   same IP packet.  [RFC4963] specifies that at high data rates, the
   16-bit IP identification field is not large enough to prevent
   frequent incorrectly assembled IP fragments.  For constrained PLC,
   the data rate is much lower than the situation mentioned in
   [RFC4963]; thus, the 16-bit tag is sufficient to assemble the
   fragments correctly.

5.  Internet Connectivity Scenarios and Topologies

   The PLC network model can be simplified to two kinds of network
   devices: PAN Coordinator (PANC) and PLC device.  The PANC is the
   primary coordinator of the PLC subnet and can be seen as a primary
   node; PLC devices are typically PLC meters and sensors.  The address
   registration and DAD features can also be deployed on the PANC, for
   example, the 6LBR [RFC6775] or the routing registrar [RFC8505].  IPv6
   over PLC networks are built as tree, mesh, or star topologies
   according to the use cases.  Generally, each PLC network has one
   PANC.  In some cases, the PLC network can have alternate coordinators
   to replace the PANC when the PANC leaves the network for some reason.
   Note that the PLC topologies in this section are based on logical
   connectivity, not physical links.  The term "PLC subnet" refers to a
   multilink subnet, in which the PLC devices share the same address
   prefix.

   The star topology is common in current PLC scenarios.  In single-hop
   star topologies, communication at the link layer only takes place
   between a PLC device and a PANC.  The PANC typically collects data
   (e.g., a meter reading) from the PLC devices and then concentrates
   and uploads the data through Ethernet or cellular networks (see
   Figure 5).  The collected data is transmitted by the smart meters
   through PLC, aggregated by a concentrator, and sent to the utility
   and then to a Meter Data Management System for data storage,
   analysis, and billing.  This topology has been widely applied in the
   deployment of smart meters, especially in apartment buildings.

                   PLC Device   PLC Device
                         \        /           +---------
                          \      /           /
                           \    /           +
                            \  /            |
          PLC Device ------ PANC ===========+  Internet
                            /  \            |
                           /    \           +
                          /      \           \
                         /        \           +---------
                   PLC Device   PLC Device

                <---------------------->
               PLC subnet (IPv6 over PLC)

            Figure 5: PLC Star Network Connected to the Internet

   A tree topology is useful when the distance between a device A and
   the PANC is beyond the PLC-allowed limit and there is another device
   B in between able to communicate with both sides.  Device B in this
   case acts as both a PLC device and a Coordinator.  For this scenario,
   the link-layer communications take place between device A and device
   B, and between device B and PANC.  An example of a PLC tree network
   is depicted in Figure 6.  This topology can be applied in smart
   street lighting, where the lights adjust the brightness to reduce
   energy consumption while sensors are deployed on the street lights to
   provide information such as light intensity, temperature, and
   humidity.  The data-transmission distance in the street lighting
   scenario is normally above several kilometers; thus, a PLC tree
   network is required.  A more sophisticated AMI network may also be
   constructed into the tree topology that is depicted in [RFC8036].  A
   tree topology is suitable for AMI scenarios that require large
   coverage but low density, e.g., the deployment of smart meters in
   rural areas.  RPL is suitable for maintenance of a tree topology in
   which there is no need for communication directly between PAN
   devices.

                          PLC Device
                               \                   +---------
               PLC Device A     \                 /
                       \         \               +
                        \         \              |
                 PLC Device B -- PANC ===========+  Internet
                        /         /              |
                       /         /               +
      PLC Device---PLC Device   /                 \
                               /                   +---------
              PLC Device---PLC Device

            <------------------------->
            PLC subnet (IPv6 over PLC)

            Figure 6: PLC Tree Network Connected to the Internet

   Mesh networking in PLC has many potential applications and has been
   studied for several years.  By connecting all nodes with their
   neighbors in communication range (see Figure 7), a mesh topology
   dramatically enhances the communication efficiency and thus expands
   the size of PLC networks.  A simple use case is the smart home
   scenario where the ON/OFF state of air conditioning is controlled by
   the state of home lights (ON/OFF) and doors (OPEN/CLOSE).  AODV-RPL
   [AODV-RPL] enables direct communication between PLC devices, without
   being obliged to transmit frames through the PANC, which is a
   requirement often cited for the AMI infrastructure.

                PLC Device---PLC Device
                    / \        / \                   +---------
                   /   \      /   \                 /
                  /     \    /     \               +
                 /       \  /       \              |
          PLC Device--PLC Device---PANC ===========+  Internet
                 \       /  \       /              |
                  \     /    \     /               +
                   \   /      \   /                 \
                    \ /        \ /                   +---------
                PLC Device---PLC Device

        <------------------------------->
            PLC subnet (IPv6 over PLC)

            Figure 7: PLC Mesh Network Connected to the Internet

6.  Operations and Manageability Considerations

   Constrained PLC networks are not managed in the same way as
   enterprise networks or carrier networks.  Constrained PLC networks,
   like the other IoT networks, are designed to be self-organized and
   self-managed.  The software or firmware is flashed into the devices
   before deployment by the vendor or operator.  And during the
   deployment process, the devices are bootstrapped, and no extra
   configuration is needed to get the devices connected to each other.
   Once a device becomes offline, it goes back to the bootstrapping
   stage and tries to rejoin the network.  The onboarding status of the
   devices and the topology of the PLC network can be visualized via the
   PANC.  The recently formed IOTOPS WG in the IETF aims to identify the
   requirements in IoT network management, and operational practices
   will be published.  Developers and operators of PLC networks should
   be able to learn operational experiences from this WG.

7.  IANA Considerations

   This document has no IANA actions.

8.  Security Considerations

   Due to the high accessibility of power grids, PLC might be
   susceptible to eavesdropping within its communication coverage, e.g.,
   one apartment tenant may have the chance to monitor the other smart
   meters in the same apartment building.  Link-layer security
   mechanisms, such as payload encryption and device authentication, are
   designed in the PLC technologies mentioned in this document.
   Additionally, an on-path malicious PLC device could eavesdrop or
   modify packets sent through it if appropriate confidentiality and
   integrity mechanisms are not implemented.

   Malicious PLC devices could paralyze the whole network via DoS
   attacks, e.g., keep joining and leaving the network frequently or
   sending multicast routing messages containing fake metrics.  A device
   may also inadvertently join a wrong or even malicious network,
   exposing its data to malicious users.  When communicating with a
   device outside the PLC network, the traffic has to go through the
   PANC.  Thus, the PANC must be a trusted entity.  Moreover, the PLC
   network must prevent malicious devices from joining the network.
   Thus, mutual authentication of a PLC network and a new device is
   important, and it can be conducted during the onboarding process of
   the new device.  Methods include protocols such as the TLS/DTLS
   Profile [RFC7925] (exchanging pre-installed certificates over DTLS),
   the Constrained Join Protocol (CoJP) [RFC9031] (which uses pre-shared
   keys), and Zero-Touch Secure Join [ZEROTOUCH] (an IoT version of the
   Bootstrapping Remote Secure Key Infrastructure (BRSKI), which uses an
   Initial Device Identifier (IDevID) and a Manufacturer Authorized
   Signing Authority (MASA) service to facilitate authentication).  It
   is also possible to use Extensible Authentication Protocol (EAP)
   methods such as the one defined in [RFC9140] via transports like
   Protocol for Carrying Authentication for Network Access (PANA)
   [RFC5191].  No specific mechanism is specified by this document, as
   an appropriate mechanism will depend upon deployment circumstances.
   In some cases, the PLC devices can be deployed in uncontrolled
   places, where the devices may be accessed physically and be
   compromised via key extraction.  The compromised device may be still
   able to join in the network since its credentials are still valid.
   When group-shared symmetric keys are used in the network, the
   consequence is even more severe, i.e., the whole network or a large
   part of the network is at risk.  Thus, in scenarios where physical
   attacks are considered to be relatively highly possible, per-device
   credentials SHOULD be used.  Moreover, additional end-to-end security
   services are complementary to the network-side security mechanisms,
   e.g., if a device is compromised and has joined in the network, and
   then it claims itself as the PANC and tries to make the rest of the
   devices join its network.  In this situation, the real PANC can send
   an alarm to the operator to acknowledge the risk.  Other behavior-
   analysis mechanisms can be deployed to recognize the malicious PLC
   devices by inspecting the packets and the data.

   IP addresses may be used to track devices on the Internet; such
   devices can often in turn be linked to individuals and their
   activities.  Depending on the application and the actual use pattern,
   this may be undesirable.  To impede tracking, globally unique and
   non-changing characteristics of IP addresses should be avoided, e.g.,
   by frequently changing the global prefix and avoiding unique link-
   layer derived IIDs in addresses.  [RFC8065] discusses the privacy
   threats when an IID is generated without sufficient entropy,
   including correlation of activities over time, location tracking,
   device-specific vulnerability exploitation, and address scanning.
   And an effective way to deal with these threats is to have enough
   entropy in the IID compared to the link lifetime.  Consider a PLC
   network with 1024 devices and a link lifetime is 8 years, according
   to the formula in [RFC8065], an entropy of 40 bits is sufficient.
   Padding the short address (12 or 16 bits) to generate the IID of a
   routable IPv6 address in the public network may be vulnerable to deal
   with address scans.  Thus, as suggested in Section 4.1, a hash
   function can be used to generate a 64-bit IID.  When the version
   number of the PLC network is changed, the IPv6 addresses can be
   changed as well.  Other schemes such as limited lease period in
   DHCPv6 [RFC8415], Cryptographically Generated Addresses (CGAs)
   [RFC3972], Temporary Address Extensions [RFC8981], Hash-Based
   Addresses (HBAs) [RFC5535], or semantically opaque addresses
   [RFC7217] SHOULD be used to enhance the IID privacy.

9.  References

9.1.  Normative References

   [IEEE_1901.1]
              IEEE, "IEEE Standard for Medium Frequency (less than 12
              MHz) Power Line Communications for Smart Grid
              Applications", DOI 10.1109/IEEESTD.2018.8360785, IEEE
              Std 1901.1, May 2018,
              <https://ieeexplore.ieee.org/document/8360785>.

   [IEEE_1901.2]
              IEEE, "IEEE Standard for Low-Frequency (less than 500 kHz)
              Narrowband Power Line Communications for Smart Grid
              Applications", DOI 10.1109/IEEESTD.2013.6679210, IEEE
              Std 1901.2, December 2013,
              <https://ieeexplore.ieee.org/document/6679210>.

   [ITU-T_G.9903]
              ITU-T, "Narrowband orthogonal frequency division
              multiplexing power line communication transceivers for
              G3-PLC networks", ITU-T Recommendation G.9903, August
              2017, <https://www.itu.int/rec/T-REC-G.9903>.

   [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
              Requirement Levels", BCP 14, RFC 2119,
              DOI 10.17487/RFC2119, March 1997,
              <https://www.rfc-editor.org/info/rfc2119>.

   [RFC2464]  Crawford, M., "Transmission of IPv6 Packets over Ethernet
              Networks", RFC 2464, DOI 10.17487/RFC2464, December 1998,
              <https://www.rfc-editor.org/info/rfc2464>.

   [RFC4291]  Hinden, R. and S. Deering, "IP Version 6 Addressing
              Architecture", RFC 4291, DOI 10.17487/RFC4291, February
              2006, <https://www.rfc-editor.org/info/rfc4291>.

   [RFC4861]  Narten, T., Nordmark, E., Simpson, W., and H. Soliman,
              "Neighbor Discovery for IP version 6 (IPv6)", RFC 4861,
              DOI 10.17487/RFC4861, September 2007,
              <https://www.rfc-editor.org/info/rfc4861>.

   [RFC4944]  Montenegro, G., Kushalnagar, N., Hui, J., and D. Culler,
              "Transmission of IPv6 Packets over IEEE 802.15.4
              Networks", RFC 4944, DOI 10.17487/RFC4944, September 2007,
              <https://www.rfc-editor.org/info/rfc4944>.

   [RFC6282]  Hui, J., Ed. and P. Thubert, "Compression Format for IPv6
              Datagrams over IEEE 802.15.4-Based Networks", RFC 6282,
              DOI 10.17487/RFC6282, September 2011,
              <https://www.rfc-editor.org/info/rfc6282>.

   [RFC6550]  Winter, T., Ed., Thubert, P., Ed., Brandt, A., Hui, J.,
              Kelsey, R., Levis, P., Pister, K., Struik, R., Vasseur,
              JP., and R. Alexander, "RPL: IPv6 Routing Protocol for
              Low-Power and Lossy Networks", RFC 6550,
              DOI 10.17487/RFC6550, March 2012,
              <https://www.rfc-editor.org/info/rfc6550>.

   [RFC6775]  Shelby, Z., Ed., Chakrabarti, S., Nordmark, E., and C.
              Bormann, "Neighbor Discovery Optimization for IPv6 over
              Low-Power Wireless Personal Area Networks (6LoWPANs)",
              RFC 6775, DOI 10.17487/RFC6775, November 2012,
              <https://www.rfc-editor.org/info/rfc6775>.

   [RFC7136]  Carpenter, B. and S. Jiang, "Significance of IPv6
              Interface Identifiers", RFC 7136, DOI 10.17487/RFC7136,
              February 2014, <https://www.rfc-editor.org/info/rfc7136>.

   [RFC8174]  Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC
              2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174,
              May 2017, <https://www.rfc-editor.org/info/rfc8174>.

   [RFC8505]  Thubert, P., Ed., Nordmark, E., Chakrabarti, S., and C.
              Perkins, "Registration Extensions for IPv6 over Low-Power
              Wireless Personal Area Network (6LoWPAN) Neighbor
              Discovery", RFC 8505, DOI 10.17487/RFC8505, November 2018,
              <https://www.rfc-editor.org/info/rfc8505>.

9.2.  Informative References

   [AODV-RPL] Perkins, C. E., Anand, S.V.R., Anamalamudi, S., and B.
              Liu, "Supporting Asymmetric Links in Low Power Networks:
              AODV-RPL", Work in Progress, Internet-Draft, draft-ietf-
              roll-aodv-rpl-15, 30 September 2022,
              <https://datatracker.ietf.org/doc/html/draft-ietf-roll-
              aodv-rpl-15>.

   [EUI-64]   IEEE Standards Association, "Guidelines for Use of
              Extended Unique Identifier (EUI), Organizationally Unique
              Identifier (OUI), and Company ID (CID)", August 2017,
              <https://standards.ieee.org/wp-
              content/uploads/import/documents/tutorials/eui.pdf>.

   [IEEE_1901.2a]
              IEEE, "IEEE Standard for Low-Frequency (less than 500 kHz)
              Narrowband Power Line Communications for Smart Grid
              Applications - Amendment 1",
              DOI 10.1109/IEEESTD.2013.6679210, IEEE Std 1901.2a,
              October 2015,
              <https://ieeexplore.ieee.org/document/7286946>.

   [RFC3972]  Aura, T., "Cryptographically Generated Addresses (CGA)",
              RFC 3972, DOI 10.17487/RFC3972, March 2005,
              <https://www.rfc-editor.org/info/rfc3972>.

   [RFC4963]  Heffner, J., Mathis, M., and B. Chandler, "IPv4 Reassembly
              Errors at High Data Rates", RFC 4963,
              DOI 10.17487/RFC4963, July 2007,
              <https://www.rfc-editor.org/info/rfc4963>.

   [RFC5191]  Forsberg, D., Ohba, Y., Ed., Patil, B., Tschofenig, H.,
              and A. Yegin, "Protocol for Carrying Authentication for
              Network Access (PANA)", RFC 5191, DOI 10.17487/RFC5191,
              May 2008, <https://www.rfc-editor.org/info/rfc5191>.

   [RFC5535]  Bagnulo, M., "Hash-Based Addresses (HBA)", RFC 5535,
              DOI 10.17487/RFC5535, June 2009,
              <https://www.rfc-editor.org/info/rfc5535>.

   [RFC7217]  Gont, F., "A Method for Generating Semantically Opaque
              Interface Identifiers with IPv6 Stateless Address
              Autoconfiguration (SLAAC)", RFC 7217,
              DOI 10.17487/RFC7217, April 2014,
              <https://www.rfc-editor.org/info/rfc7217>.

   [RFC7925]  Tschofenig, H., Ed. and T. Fossati, "Transport Layer
              Security (TLS) / Datagram Transport Layer Security (DTLS)
              Profiles for the Internet of Things", RFC 7925,
              DOI 10.17487/RFC7925, July 2016,
              <https://www.rfc-editor.org/info/rfc7925>.

   [RFC7973]  Droms, R. and P. Duffy, "Assignment of an Ethertype for
              IPv6 with Low-Power Wireless Personal Area Network
              (LoWPAN) Encapsulation", RFC 7973, DOI 10.17487/RFC7973,
              November 2016, <https://www.rfc-editor.org/info/rfc7973>.

   [RFC8036]  Cam-Winget, N., Ed., Hui, J., and D. Popa, "Applicability
              Statement for the Routing Protocol for Low-Power and Lossy
              Networks (RPL) in Advanced Metering Infrastructure (AMI)
              Networks", RFC 8036, DOI 10.17487/RFC8036, January 2017,
              <https://www.rfc-editor.org/info/rfc8036>.

   [RFC8065]  Thaler, D., "Privacy Considerations for IPv6 Adaptation-
              Layer Mechanisms", RFC 8065, DOI 10.17487/RFC8065,
              February 2017, <https://www.rfc-editor.org/info/rfc8065>.

   [RFC8415]  Mrugalski, T., Siodelski, M., Volz, B., Yourtchenko, A.,
              Richardson, M., Jiang, S., Lemon, T., and T. Winters,
              "Dynamic Host Configuration Protocol for IPv6 (DHCPv6)",
              RFC 8415, DOI 10.17487/RFC8415, November 2018,
              <https://www.rfc-editor.org/info/rfc8415>.

   [RFC8981]  Gont, F., Krishnan, S., Narten, T., and R. Draves,
              "Temporary Address Extensions for Stateless Address
              Autoconfiguration in IPv6", RFC 8981,
              DOI 10.17487/RFC8981, February 2021,
              <https://www.rfc-editor.org/info/rfc8981>.

   [RFC9010]  Thubert, P., Ed. and M. Richardson, "Routing for RPL
              (Routing Protocol for Low-Power and Lossy Networks)
              Leaves", RFC 9010, DOI 10.17487/RFC9010, April 2021,
              <https://www.rfc-editor.org/info/rfc9010>.

   [RFC9031]  Vučinić, M., Ed., Simon, J., Pister, K., and M.
              Richardson, "Constrained Join Protocol (CoJP) for 6TiSCH",
              RFC 9031, DOI 10.17487/RFC9031, May 2021,
              <https://www.rfc-editor.org/info/rfc9031>.

   [RFC9140]  Aura, T., Sethi, M., and A. Peltonen, "Nimble Out-of-Band
              Authentication for EAP (EAP-NOOB)", RFC 9140,
              DOI 10.17487/RFC9140, December 2021,
              <https://www.rfc-editor.org/info/rfc9140>.

   [SCENA]    Cano, C., Pittolo, A., Malone, D., Lampe, L., Tonello, A.,
              and A. Dabak, "State of the Art in Power Line
              Communications: From the Applications to the Medium", IEEE
              Journal on Selected Areas in Communications, Volume 34,
              Issue 7, DOI 10.1109/JSAC.2016.2566018, July 2016,
              <https://ieeexplore.ieee.org/document/7467440>.

   [ZEROTOUCH]
              Richardson, M., "6tisch Zero-Touch Secure Join protocol",
              Work in Progress, Internet-Draft, draft-ietf-6tisch-
              dtsecurity-zerotouch-join-04, 8 July 2019,
              <https://datatracker.ietf.org/doc/html/draft-ietf-6tisch-
              dtsecurity-zerotouch-join-04>.

Acknowledgements

   We gratefully acknowledge suggestions from the members of the IETF
   6lo Working Group.  Great thanks to Samita Chakrabarti and Gabriel
   Montenegro for their feedback and support in connecting the IEEE and
   ITU-T sides.  The authors thank Scott Mansfield, Ralph Droms, and Pat
   Kinney for their guidance in the liaison process.  The authors wish
   to thank Stefano Galli, Thierry Lys, Yizhou Li, Yuefeng Wu, and
   Michael Richardson for their valuable comments and contributions.
   The authors wish to thank Carles Gomez for shepherding this document.
   The authors also thank Paolo Volpato for delivering the presentation
   at IETF 113.  Sincere acknowledgements to the valuable comments from
   the following reviewers: Dave Thaler, Dan Romascanu, Murray
   Kucherawy, Benjamin Kaduk, Alvaro Retana, Éric Vyncke, Meral
   Shirazipour, Roman Danyliw, and Lars Eggert.

Authors' Addresses

   Jianqiang Hou
   Huawei Technologies
   101 Software Avenue,
   Nanjing
   210012
   China
   Email: houjianqiang@huawei.com


   Bing Liu
   Huawei Technologies
   Haidian District
   No. 156 Beiqing Rd.
   Beijing
   100095
   China
   Email: remy.liubing@huawei.com


   Yong-Geun Hong
   Daejeon University
   Dong-gu
   62 Daehak-ro
   Daejeon
   34520
   Republic of Korea
   Email: yonggeun.hong@gmail.com


   Xiaojun Tang
   State Grid Electric Power Research Institute
   19 Chengxin Avenue
   Nanjing
   211106
   China
   Email: itc@sgepri.sgcc.com.cn


   Charles E. Perkins
   Lupin Lodge
   Email: charliep@computer.org


ERRATA